DYDmitri Yarekha

Dmitri Yarekha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dmitri Yarekha has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • InGaAs quantum dot chains grown by twofold selective area molecular beam epitaxy

    by Clément Barbot, Claire Rondeau-Body, Christophe Coinon, Yves Deblock, Pascal Tilmant, François Vaurette, Dmitri Yarekha, Maxime Berthe, Louis Thomas, Heinrich Diesinger, et al.

    Increasing quantum confinement in semiconductor quantum dot (QD) systems is essential to perform robust simulations of many-body physics. By combining molecular beam epitaxy and lithographic techniques, we developed an approach consisting of a twofold selective area growth to build QD chains. Starting from 15 nm-thick and 65 nm-wide in-plane In0.53Ga0.47As nanowires on InP substrates, linear arrays of In0.53Ga0.47As QDs were grown on top, with tunable lengths and separations. Kelvin probe force microscopy performed at room temperature revealed a change of quantum confinement in chains with decreasing QD sizes, which was further emphasized by the spectral shift of quantum levels resolved in the conduction band with low temperature scanning tunneling spectroscopy. This approach, which allows the controlled formation of 25 nm-thick QDs with a minimum length and separation of 30 nm and 22 nm respectively, is suitable for the construction of scalable fermionic quantum lattices.


  • Экспериментальное изучение распределения упругих напряжений в периимплантатной кости при зубном протезировании.

    by Первый Санкт-Петербургский Государственный Медицинский Университет Имени Академика И.п. Павлова, Владимир Трезубов, Максим Мишнев, Новгородский Государственный Университет Им. Ярослава Мудрого, Юрий Паршин, Виктор Модестов, Санкт-Петербургский Политехнический Университет Петра Великого, Денис Яреха

    В мире продолжается изучение биомеханики имплантационных зубных протезов и их искусственных опор. При этом отмечено различное отношение к наклонному положению дистальных имплантатов в кости и их двусторонней (мезиальной и дистальной) нагрузке. Отсутствие единого взгляда на рассматриваемую проблему определило цель исследования изучить в эксперименте распределение напряжений в периимплантатной кости у вертикальных (отвесных) и наклоненных имплантатов с отсутствием или наличием дистально расположенного тела протеза различной протяжённости с односторонней опорой на этих искусственных опорах. Для эксперимента нами использовано математическое моделирование методом конечных элементов. С его помощью изучались распределения и величины упругих напряжений в периимплантатной кости. В качестве геометрической модели использована модель верхней челюсти с установленным на ней имплантационным протезом, опирающимся на 4 имплантата. Следует отметить, что увеличение напряжения в материале протеза и компактной кости не являлось критичным и было гораздо меньше пределов прочности указанных сред при наклоне дистального имплантата с наличием дорзального тела с односторонней опорой на дистальном имплантате. Что же касается губчатой кости, то напряжения в ней в целом не показали зависимости положения имплантата и слабо возрастали при увеличении мезиодистальной протяженности дорзального тела протеза с односторонней опорой. Таким образом, математическое моделирование методом конечных элементов показало некритичность распределения упругих напряжений в протезе, дистальном имплантате, компактной и губчатой кости при различной конфигурации дистальных отделов протеза.

  • Experimental study of the distribution of elasticity in the peri-implant bone during prosthetics

    by Pavlov First Saint Petersburg State Medical University, Vladimir Trezubov, Maxim Mishnev, Yaroslav-the-Wise Novgorod State University, Yuri Parshin, Victor Modestov, Peter the Great Saint Petersburg Polytechnic University, Denis Yarekha

    The world continues to study the biomechanics of implant dentures and their artifi-cial supports. At the same time, different attitudes to the inclined position of distal im-plants in the bone and their bilateral (mesial and distal) loading were noted. The lack of a unified view of the problem under consideration set us the goal to study in the experi-ment the distribution of stresses in the peri-implant bone in vertical (sheer) and inclined implants with the absence or presence of a distally located prosthesis body of various lengths with one-sided support on these artificial supports. For the experiment, we used mathematical modeling by the finite element method. It was used to study the distribution and magnitude of elastic stresses in the peri-implant bone. As a geometric model, a model of the upper jaw with an implant prosthesis installed on it, based on 4 implants, was used. It should be noted that the increase in stress in the material of the prosthesis and compact bone was not critical and was much less than the ultimate strength of these media when the distal implant was tilted with the presence of a dorsal body with one-sided support on the distal implant. As for the spongy bone, the stresses in it showed no dependence on the position of the implant as a whole and slightly increased with an increase in the mesiodistal length of the dorsal body of the prosthesis with one-sided support. Thus, mathematical modeling by the finite element method showed the uncritical distribution of elastic stresses in the prosthesis, distal im-plant, compact and cancellous bone


  • Surface micromachining of chip-edge silicon microcantilevers using xenon difluoride etching of silicon-on-insulator

    by Thomas Lerond, Dmitri Yarekha, Vanessa Avramovic, Thierry Mélin, Steve Arscott

    We demonstrate a straightforward surface micromachining process for the rapid prototyping of thin ‘chip-edge’ silicon microcantilevers protruding from the edge of a silicon-on-insulator (SOI) chip. The process uses a single photolithographic mask—with xenon difluoride used to both pattern the silicon microcantilevers and release them by etching part of the underlying silicon wafer. During the release step, the silicon microcantilevers are protected from the xenon difluoride by a combination of photoresist and buried silicon dioxide. The use of common microfabrication materials (SOI and positive photoresist) and chemicals (buffered hydrofluoric acid and xenon difluoride), along with a maximum process temperature of 100 °C, makes for a generic, soft micromachining process which is—in principle—compatible with preserving the integrity of any pre-patterned circuitry present on the silicon microcantilever top surface. Doppler vibrometry measurements of the silicon microcantilevers reveal a well-defined resonant frequency and a quality factor comparable with that of similar silicon microcantilevers fabricated using other means. Our enabling technological process allows the rapid prototyping of chip-edge silicon microcantilevers—potentially integrating sensitive circuitry for novel probe technologies—by avoiding the relatively cumbersome, expensive, and potentially circuit-damaging front-to-back processing/deep etching combination.


  • Electron lifetime measurements of heavily C-doped InGaAs and GaAsSb as a function of the doping density

    by D. Vignaud, D. A. Yarekha, J. F. Lampin, M. Zaknoune, S. Godey, F. Mollot

    The electron lifetime has been measured by time-resolved differential transmission experiments in heavily carbon-doped p -type InGaAs and GaAsSb, grown lattice matched on InP by molecular beam epitaxy. It is found inversely proportional to the square of the doping in both alloys, a result typical of Auger recombination dominated processes. It is shown that the electron lifetime is almost twice larger in GaAsSb than in InGaAs for large p -type doping, thus confirming that GaAsSb is a strong contender for the base material of double heterostructure bipolar transistors on InP.