Xuan Hao Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xuan Hao Lin has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Sam Fong Yau Li
Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
12 shared publications Sam Fong Yau Li
7 shared publications- Gaik-Khuan Chuah
Department of Chemistry, National University of Singapore, 3 Science Drive 3, Kent Ridge, 117543 Singapore
4 shared publications - Stephan Jaenicke
Department of Chemistry, National University of Singapore, 3 Science Drive 3, Kent Ridge, 117543 Singapore
4 shared publications Jialing Song
International Joint Laboratory Catalyst Chemistry, Department of Chemistry, College of Science, Shanghai University, Shanghai 200444, China
2 shared publications- Liang Ying Ee
Department of Chemistry, College of Humanities and Sciences, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore
2 shared publications
Latest Publications
- Open Access
Regulation of Template Ionization and Template–Monomer Interactions for Enhanced Molecular Imprinting and Selective Detection of Promethazine
A molecularly imprinted polymer (MIP)-based quartz crystal microbalance (QCM) sensor was developed for the selective detection of promethazine (PMZ) through deliberate regulation of template–monomer interactions during the molecular imprinting process. Various functional monomer systems were systematically evaluated to optimize intermolecular recognition, among which the combination of 4-vinylpyridine (4-VP) and 2-acrylamido-2-methylpropanesulfonic acid (AAMPS) exhibited the strongest interaction toward PMZ. Furthermore, protonation of PMZ using hydrochloric acid significantly enhanced electrostatic complexation between the template and functional monomers, leading to improved pre-polymerization organization, more effective imprinting-site formation and high selectivity towards target analytes. The resulting MIP-QCM sensor exhibited a linear response toward PMZ over the concentration range of 50–2000 ppb with a correlation coefficient (R2) of 0.99148 and a detection limit of 27.4 ppb. The sensor demonstrated favorable selectivity against structurally related compounds, strong anti-interference performance under highly competitive matrix conditions, and excellent regeneration stability, retaining 97.9% of its original response after ten regeneration cycles. Recovery studies in spiked tap water and carbonated beverage samples yielded recoveries ranging from 94.7% to 112.6%. These results demonstrate that regulating template ionization and template–monomer interactions is an effective strategy for improving imprinting-site quality and molecular recognition performance. The proposed approach provides new insight into the rational design of highly selective MIPs for basic pharmaceutical compounds and offers a promising platform for environmental, pharmaceutical and forensic monitoring applications.
Open AccessRegulation of Template Ionization and Template–Monomer Interactions for Enhanced Molecular Imprinting and Selective Detection of Promethazine
A molecularly imprinted polymer (MIP)-based quartz crystal microbalance (QCM) sensor was developed for the selective detection of promethazine (PMZ) through deliberate regulation of template–monomer interactions during the molecular imprinting process. Various functional monomer systems were systematically evaluated to optimize intermolecular recognition, among which the combination of 4-vinylpyridine (4-VP) and 2-acrylamido-2-methylpropanesulfonic acid (AAMPS) exhibited the strongest interaction toward PMZ. Furthermore, protonation of PMZ using hydrochloric acid significantly enhanced electrostatic complexation between the template and functional monomers, leading to improved pre-polymerization organization, more effective imprinting-site formation and high selectivity towards target analytes. The resulting MIP-QCM sensor exhibited a linear response toward PMZ over the concentration range of 50–2000 ppb with a correlation coefficient (R2) of 0.99148 and a detection limit of 27.4 ppb. The sensor demonstrated favorable selectivity against structurally related compounds, strong anti-interference performance under highly competitive matrix conditions, and excellent regeneration stability, retaining 97.9% of its original response after ten regeneration cycles. Recovery studies in spiked tap water and carbonated beverage samples yielded recoveries ranging from 94.7% to 112.6%. These results demonstrate that regulating template ionization and template–monomer interactions is an effective strategy for improving imprinting-site quality and molecular recognition performance. The proposed approach provides new insight into the rational design of highly selective MIPs for basic pharmaceutical compounds and offers a promising platform for environmental, pharmaceutical and forensic monitoring applications.
- Open Access
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151  (8) , 2227-2234
Tuning MIP-QCM selectivity for zinc ions via cross-linker/monomer ratio
A Zn 2+ MIP sensor was developed and optimised for water analysis. Key parameters, specifically the cross-linker/monomer ratio, ensure high selectivity, stability, and rapid response. High recovery in real matrices confirms its environmental utility.
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151  (8) , 2227-2234
Open AccessTuning MIP-QCM selectivity for zinc ions via cross-linker/monomer ratio
A Zn 2+ MIP sensor was developed and optimised for water analysis. Key parameters, specifically the cross-linker/monomer ratio, ensure high selectivity, stability, and rapid response. High recovery in real matrices confirms its environmental utility.
- 4 December 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 373, 123519
An efficient digestion technique for the analysis of heavy metals, Ca and Al in solid waste incineration ash
- 4 December 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 373, 123519
An efficient digestion technique for the analysis of heavy metals, Ca and Al in solid waste incineration ash
- Open Access
- 30 July 2024
- Published by Elsevier in Chemical Engineering Journal Advances
- Vol. 19
Accelerated de-chelation of EDTA-metal complexes: A novel and versatile approach for wastewater and solid waste remediation
- 30 July 2024
- Published by Elsevier in Chemical Engineering Journal Advances
- Vol. 19
Open AccessAccelerated de-chelation of EDTA-metal complexes: A novel and versatile approach for wastewater and solid waste remediation
- Open Access
- 2 May 2024
- Published by MDPI AG in Chemosensors
- Vol. 12  (5) , 72
Research Progress on Molecularly Imprinted Materials for the Screening and Identification of Organic Pollutants
Organic pollutants, distinguished by their persistence and bioaccumulation in the environment, pose significant ecological and health threats that surpass those of traditional pollutants. Crucial to understanding their environmental behavior, health risks, and mitigation strategies, is the screening and identification of these pollutants. This process indispensably employs functional materials, among which molecularly imprinted polymers (MIPs) prove to be particularly advantageous because of their specific recognition capabilities and extensive application range. This review presents cutting-edge techniques and strategies for the fabrication of MIPs, including surface imprinting techniques and dummy molecular strategies. It encapsulates the last five years’ advancements in MIP research within the domains of sample pretreatment, as well as optical and electrochemical sensing analysis. The objective of this discourse is to potentially foster the evolution of MIP technology and establish the groundwork for its transition from lab-scale to commercial production.
- 2 May 2024
- Published by MDPI AG in Chemosensors
- Vol. 12  (5) , 72
Open AccessResearch Progress on Molecularly Imprinted Materials for the Screening and Identification of Organic Pollutants
Organic pollutants, distinguished by their persistence and bioaccumulation in the environment, pose significant ecological and health threats that surpass those of traditional pollutants. Crucial to understanding their environmental behavior, health risks, and mitigation strategies, is the screening and identification of these pollutants. This process indispensably employs functional materials, among which molecularly imprinted polymers (MIPs) prove to be particularly advantageous because of their specific recognition capabilities and extensive application range. This review presents cutting-edge techniques and strategies for the fabrication of MIPs, including surface imprinting techniques and dummy molecular strategies. It encapsulates the last five years’ advancements in MIP research within the domains of sample pretreatment, as well as optical and electrochemical sensing analysis. The objective of this discourse is to potentially foster the evolution of MIP technology and establish the groundwork for its transition from lab-scale to commercial production.
- Open Access
Ion-Imprinted Polymer-Based Sensor for the Detection of Mercury Ions
In this work, the development of a novel method for the detection of mercury (II) ions in wastewater using a mercury ion-imprinted polymer (IIP) combined with a quartz crystal microbalance (QCM) is described. The IIP was successfully synthesized via the polymerization of a of a novel fluorescein- and 2-aminophenol-functionalized methacrylic acid monomer, which was noted to have high binding affinity to mercury (II) ions. This polymer was subsequently coated on a QCM chip to create an IIP-QCM sensor. This sensor was established to have high selectivity and good sensitivity to mercury (II) ions, and had a limit of detection (LOD) of 14.17 ppb, a limit of quantification (LOQ) of 42.94 ppb, a signal-to-noise ratio (S/N) of 4.29, good repeatability, and a working range of 42.94 ppb to 2 ppm. The sensor was also able to analyze tap water and wastewater samples. The IIP-QCM is, therefore, promising as a highly selective, cost-effective, and rapid mercury ion sensor for applications involving the detection of mercury in wastewater.
Open AccessIon-Imprinted Polymer-Based Sensor for the Detection of Mercury Ions
In this work, the development of a novel method for the detection of mercury (II) ions in wastewater using a mercury ion-imprinted polymer (IIP) combined with a quartz crystal microbalance (QCM) is described. The IIP was successfully synthesized via the polymerization of a of a novel fluorescein- and 2-aminophenol-functionalized methacrylic acid monomer, which was noted to have high binding affinity to mercury (II) ions. This polymer was subsequently coated on a QCM chip to create an IIP-QCM sensor. This sensor was established to have high selectivity and good sensitivity to mercury (II) ions, and had a limit of detection (LOD) of 14.17 ppb, a limit of quantification (LOQ) of 42.94 ppb, a signal-to-noise ratio (S/N) of 4.29, good repeatability, and a working range of 42.94 ppb to 2 ppm. The sensor was also able to analyze tap water and wastewater samples. The IIP-QCM is, therefore, promising as a highly selective, cost-effective, and rapid mercury ion sensor for applications involving the detection of mercury in wastewater.
- Open Access
- 19 May 2023
- Published by MDPI AG in Chemosensors
- Vol. 11  (5) , 302
Highly Selective Arsenite Sensor Based on Gold Nanoparticles and Ionic Liquids
Here, we report a highly selective arsenite (As(III)) sensor based on gold nanoparticles (AuNPs) and ionic liquids (ILs). AuNPs were citrate-capped with negative charges on their surfaces, and could aggregate and precipitate once electrolytes were introduced to neutralize the negative charges. In this study, we discovered that organic ILs, behaving similarly to inorganic electrolytes such as NaCl, could induce the aggregation and precipitation of AuNPs much more efficiently than inorganic electrolytes. Since As(III) inhibited while ILs promoted the aggregation of AuNPs, we examined the interactions between AuNPs, As(III), and ILs and the possibility of using ILs and AuNPs as a sensing probe to detect arsenite and determine its concentration. Six different ILs were evaluated for this purpose in this study. Repeatability, interference, stability, selectivity, and sensitivity were investigated to evaluate the As(III) sensing probe. The limit of detection (LOD) of the sensor sBMP was as low as 0.18 ppb, ranked as the second lowest among the reported arsenite sensors. The sensing of arsenite was also demonstrated with real water samples and was cross-validated with ICP-OES.
- 19 May 2023
- Published by MDPI AG in Chemosensors
- Vol. 11  (5) , 302
Open AccessHighly Selective Arsenite Sensor Based on Gold Nanoparticles and Ionic Liquids
Here, we report a highly selective arsenite (As(III)) sensor based on gold nanoparticles (AuNPs) and ionic liquids (ILs). AuNPs were citrate-capped with negative charges on their surfaces, and could aggregate and precipitate once electrolytes were introduced to neutralize the negative charges. In this study, we discovered that organic ILs, behaving similarly to inorganic electrolytes such as NaCl, could induce the aggregation and precipitation of AuNPs much more efficiently than inorganic electrolytes. Since As(III) inhibited while ILs promoted the aggregation of AuNPs, we examined the interactions between AuNPs, As(III), and ILs and the possibility of using ILs and AuNPs as a sensing probe to detect arsenite and determine its concentration. Six different ILs were evaluated for this purpose in this study. Repeatability, interference, stability, selectivity, and sensitivity were investigated to evaluate the As(III) sensing probe. The limit of detection (LOD) of the sensor sBMP was as low as 0.18 ppb, ranked as the second lowest among the reported arsenite sensors. The sensing of arsenite was also demonstrated with real water samples and was cross-validated with ICP-OES.
- 16 May 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 11  (23) , 12342-12353
Molten salt synthesis of a highly crystalline graphitic carbon nitride homojunction from a deep eutectic solvent for selective photocatalytic oxidation
The construction of homojunctions in graphitic carbon nitride is regarded as an efficient approach to improve the charge separation and photocatalytic activity. However, the enhanced activity is still far from satisfactory due to the low crystalline bulk structure. Herein, a highly crystalline graphitic carbon nitride homojunction is synthesized by calcination of a mixture of NH4SCN and urea, which forms a deep eutectic solvent using NaCl/KCl molten salts as the preparation medium. The homogeneity of the liquid precursor ensures an intimate homojunction interface, facilitating the charge separation, and the highly crystalline bulk structure builds a highway for rapidly transferring charge to the surface. Consequently, the bulk charge recombination is suppressed, and the spatial separation and transfer efficiency of charges are significantly improved. Compared to low crystalline homojunctions, this highly crystalline homojunction showed 15 times higher activity for the selective photocatalytic oxidation of benzyl alcohol to benzaldehyde. This work provides a simple strategy to construct a highly crystalline graphitic carbon nitride homojunction for solar energy conversion.
- 16 May 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 11  (23) , 12342-12353
Molten salt synthesis of a highly crystalline graphitic carbon nitride homojunction from a deep eutectic solvent for selective photocatalytic oxidation
The construction of homojunctions in graphitic carbon nitride is regarded as an efficient approach to improve the charge separation and photocatalytic activity. However, the enhanced activity is still far from satisfactory due to the low crystalline bulk structure. Herein, a highly crystalline graphitic carbon nitride homojunction is synthesized by calcination of a mixture of NH4SCN and urea, which forms a deep eutectic solvent using NaCl/KCl molten salts as the preparation medium. The homogeneity of the liquid precursor ensures an intimate homojunction interface, facilitating the charge separation, and the highly crystalline bulk structure builds a highway for rapidly transferring charge to the surface. Consequently, the bulk charge recombination is suppressed, and the spatial separation and transfer efficiency of charges are significantly improved. Compared to low crystalline homojunctions, this highly crystalline homojunction showed 15 times higher activity for the selective photocatalytic oxidation of benzyl alcohol to benzaldehyde. This work provides a simple strategy to construct a highly crystalline graphitic carbon nitride homojunction for solar energy conversion.
- Open Access
- 16 January 2023
- Published by MDPI AG in Chemosensors
- Vol. 11  (1) , 72
Nanogel for Selective Recognition of Nanoparticles in Water Samples
Nanoparticles (NPs) represent emerging pollutants that still pose analytical challenges for their detection in environmentally relevant samples due to their extremely low concentrations, high colloidal background, and the need to perform speciation analysis. They are also one of the interfering matrices during the analysis of metal ions and contaminants in water samples. Currently, conventional analytical techniques such as Transmission Electron Microscopy (TEM) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are used for the detection of NPs, but such techniques require bulky instrumentation and are difficult to be automated for online analysis. In this study, we aim to develop a nanoparticle-imprinted hydrogel (NPIH, NANOGEL) to detect and capture NPs in water samples. The principle of the Nanogel originates from the well-known concept of molecularly imprinted polymers (MIPs). Cadmium sulfide/Selenide/Zinc sulfide core/shell quantum dots (QDs) were used as the template NP, creating specific pore cavities in the Nanogel that can selectively bind to certain analytes. Quantification of NPs detected in water samples was then made possible by transducing this selective detection process into an analytical signal using a quartz crystal microbalance (QCM). The Nanogel was shown to demonstrate good repeatability, reproducibility, and stability in terms of its performance. The high selectivity of the Nanogel was determined to be attributed to the size of cavities and their surface characteristics. Ionic interference was present and, heavy metal cations showed an affinity for the NANOGEL synthesized; however, they were demonstrated to be minimized by the selection of porogenic solvents during the synthesis of NANOGEL. We believe that the Nanogel would provide a highly selective and sensitive approach for the detection of NPs in aqueous samples and the removal of NPs from contaminated water resources. It will serve useful in environmental applications.
- 16 January 2023
- Published by MDPI AG in Chemosensors
- Vol. 11  (1) , 72
Open AccessNanogel for Selective Recognition of Nanoparticles in Water Samples
Nanoparticles (NPs) represent emerging pollutants that still pose analytical challenges for their detection in environmentally relevant samples due to their extremely low concentrations, high colloidal background, and the need to perform speciation analysis. They are also one of the interfering matrices during the analysis of metal ions and contaminants in water samples. Currently, conventional analytical techniques such as Transmission Electron Microscopy (TEM) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are used for the detection of NPs, but such techniques require bulky instrumentation and are difficult to be automated for online analysis. In this study, we aim to develop a nanoparticle-imprinted hydrogel (NPIH, NANOGEL) to detect and capture NPs in water samples. The principle of the Nanogel originates from the well-known concept of molecularly imprinted polymers (MIPs). Cadmium sulfide/Selenide/Zinc sulfide core/shell quantum dots (QDs) were used as the template NP, creating specific pore cavities in the Nanogel that can selectively bind to certain analytes. Quantification of NPs detected in water samples was then made possible by transducing this selective detection process into an analytical signal using a quartz crystal microbalance (QCM). The Nanogel was shown to demonstrate good repeatability, reproducibility, and stability in terms of its performance. The high selectivity of the Nanogel was determined to be attributed to the size of cavities and their surface characteristics. Ionic interference was present and, heavy metal cations showed an affinity for the NANOGEL synthesized; however, they were demonstrated to be minimized by the selection of porogenic solvents during the synthesis of NANOGEL. We believe that the Nanogel would provide a highly selective and sensitive approach for the detection of NPs in aqueous samples and the removal of NPs from contaminated water resources. It will serve useful in environmental applications.
- Top Cited Papers
- 1 January 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 427
Novel Fe-based metal–organic framework (MOF) modified carbon nanofiber as a highly selective and sensitive electrochemical sensor for tetracycline detection
- 1 January 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 427
Top Cited PapersNovel Fe-based metal–organic framework (MOF) modified carbon nanofiber as a highly selective and sensitive electrochemical sensor for tetracycline detection