Eliana Biundo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eliana Biundo has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Jose Garcia-Ruiz
Pharmacology Department, University of Málaga, Málaga, Spain
3 shared publications - David Salisbury
Royal Institute of International Affairs, Chatham House, London SW1Y 4LE, UK
3 shared publications - Ekkehard Beck
Moderna, Inc., Cambridge, MA 02142, USA
3 shared publications - Jürgen Wasem
Institute of Healthcare Management, Universität Duisburg-Essen, 45127 Essen, Germany
3 shared publications - Maarten Jacobus Postma
Department of Health Sciences, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands, The Netherlands
3 shared publications - Mark Doherty
GSK, Wavre, Belgium
3 shared publications
Latest Publications
- Open Access
Capturing the Value of Vaccination within Health Technology Assessment and Health Economics—Practical Considerations for Expanding Valuation by Including Key Concepts
Following the development of a value of vaccination (VoV) framework for health technology assessment/cost-effectiveness analysis (HTA/CEA), and identification of three vaccination benefits for near-term inclusion in HTA/CEA, this final paper provides decision makers with methods and examples to consider benefits of health systems strengthening (HSS), equity, and macroeconomic gains. Expert working groups, targeted literature reviews, and case studies were used. Opportunity cost methods were applied for HSS benefits of rotavirus vaccination. Vaccination, with HSS benefits included, reduced the incremental cost-effectiveness ratio (ICER) by 1.4–50.5% (to GBP 11,552–GBP 23,016) depending on alternative conditions considered. Distributional CEA was applied for health equity benefits of meningococcal vaccination. Nearly 80% of prevented cases were among the three most deprived groups. Vaccination, with equity benefits included, reduced the ICER by 22–56% (to GBP 7014–GBP 12,460), depending on equity parameters. Macroeconomic models may inform HTA deliberative processes (e.g., disease impact on the labour force and the wider economy), or macroeconomic outcomes may be assessed for individuals in CEAs (e.g., impact on non-health consumption, leisure time, and income). These case studies show how to assess broader vaccination benefits in current HTA/CEA, providing decision makers with more accurate and complete VoV assessments. More work is needed to refine inputs and methods, especially for macroeconomic gains.
Open AccessCapturing the Value of Vaccination within Health Technology Assessment and Health Economics—Practical Considerations for Expanding Valuation by Including Key Concepts
Following the development of a value of vaccination (VoV) framework for health technology assessment/cost-effectiveness analysis (HTA/CEA), and identification of three vaccination benefits for near-term inclusion in HTA/CEA, this final paper provides decision makers with methods and examples to consider benefits of health systems strengthening (HSS), equity, and macroeconomic gains. Expert working groups, targeted literature reviews, and case studies were used. Opportunity cost methods were applied for HSS benefits of rotavirus vaccination. Vaccination, with HSS benefits included, reduced the incremental cost-effectiveness ratio (ICER) by 1.4–50.5% (to GBP 11,552–GBP 23,016) depending on alternative conditions considered. Distributional CEA was applied for health equity benefits of meningococcal vaccination. Nearly 80% of prevented cases were among the three most deprived groups. Vaccination, with equity benefits included, reduced the ICER by 22–56% (to GBP 7014–GBP 12,460), depending on equity parameters. Macroeconomic models may inform HTA deliberative processes (e.g., disease impact on the labour force and the wider economy), or macroeconomic outcomes may be assessed for individuals in CEAs (e.g., impact on non-health consumption, leisure time, and income). These case studies show how to assess broader vaccination benefits in current HTA/CEA, providing decision makers with more accurate and complete VoV assessments. More work is needed to refine inputs and methods, especially for macroeconomic gains.
- Open Access
- 15 October 2021
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 5 (2) , e27720
Clinic Time Required for Remote and In-Person Management of Patients With Cardiac Devices: Time and Motion Workflow Evaluation
Background: The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. Objective: This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. Methods: A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. Results: A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. Conclusions: The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow.
- 15 October 2021
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 5 (2) , e27720
Open AccessClinic Time Required for Remote and In-Person Management of Patients With Cardiac Devices: Time and Motion Workflow Evaluation
Background: The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. Objective: This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. Methods: A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. Results: A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. Conclusions: The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow.
- Open Access
- 4 February 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Clinic Time Required for Remote and In-Person Management of Patients With Cardiac Devices: Time and Motion Workflow Evaluation (Preprint)
BACKGROUND The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. OBJECTIVE This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. METHODS A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. RESULTS A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. CONCLUSIONS The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow. CLINICALTRIAL
- 4 February 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessClinic Time Required for Remote and In-Person Management of Patients With Cardiac Devices: Time and Motion Workflow Evaluation (Preprint)
BACKGROUND The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. OBJECTIVE This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. METHODS A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. RESULTS A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. CONCLUSIONS The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow. CLINICALTRIAL