Abd Ghani Kay Dora
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abd Ghani Kay Dora has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
N. H. Hamid
Faculty of Civil Engineering, Universiti Teknologi MARA, 13500, Permatang Pauh, Pulau Pinang, Malaysia
5 shared publicationsM I F Rozli
3 shared publicationsN M Amin
3 shared publicationsNor Hayati Hamid
Universiti Teknologi MARA
3 shared publicationsC M C J M Hilmi Safiuddin
2 shared publicationsJ Ahmad
Faculty of Civil Engineering, Universiti Teknologi MARA, Cawangan Pulau Pinang, 13500 Permatang Pauh, Penang, Malaysia
2 shared publications
Latest Publications
- 30 November 2023
- Published by Springer Nature
- p. 211-220
Deformed Shape and Ductility of Remodelled Reinforced Concrete Heritage Building in Pulau Pinang Subjected to Moderate Seismic Excitation
- 30 November 2023
- Published by Springer Nature
- p. 211-220
Deformed Shape and Ductility of Remodelled Reinforced Concrete Heritage Building in Pulau Pinang Subjected to Moderate Seismic Excitation
- Open Access
- 19 July 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 31 (2) , 62-70
The Ideal Percentage of Rubberized Engineered Cementitious Composite (RECC) as Partial Sand Replacement
The demand for materials to retrofit earthquake-prone high-rise buildings and road vehicle tire manufacturing has led to crumb rubber as a partial sand replacement. This trend, in turn, has contributed to the rapid growth of urbanisation. Engineered Cementitious Composite (ECC) comprises sand, cement, fibres, and admixtures as primary materials and does not require the addition of coarse aggregates to the mix. This study aims to determine the ideal percentage of Rubberized Engineered Cementitious Composite (RECC) as a partial sand replacement. The mechanical properties, such as the compressive and splitting tensile strength, were evaluated at varying percentages of crumb rubber (0%, 5%, 10%, 15%, and 20%). Due to the increased percentages of crumb rubber as a partial sand replacement into ECC, the compressive strength and tensile strength of RECC were significantly reduced. Despite these reductions, all the mixture achieved its minimum acceptable compressive strength of 35 MPa, and tensile strength is 2.31MPa. The ideal percentage of crumb rubber as partial sand replacement in ECC or RECC is 5%. However, more extensive tests can be conducted in the future to determine the flexural strength of different percentages of crumb rubber.
- 19 July 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 31 (2) , 62-70
Open AccessThe Ideal Percentage of Rubberized Engineered Cementitious Composite (RECC) as Partial Sand Replacement
The demand for materials to retrofit earthquake-prone high-rise buildings and road vehicle tire manufacturing has led to crumb rubber as a partial sand replacement. This trend, in turn, has contributed to the rapid growth of urbanisation. Engineered Cementitious Composite (ECC) comprises sand, cement, fibres, and admixtures as primary materials and does not require the addition of coarse aggregates to the mix. This study aims to determine the ideal percentage of Rubberized Engineered Cementitious Composite (RECC) as a partial sand replacement. The mechanical properties, such as the compressive and splitting tensile strength, were evaluated at varying percentages of crumb rubber (0%, 5%, 10%, 15%, and 20%). Due to the increased percentages of crumb rubber as a partial sand replacement into ECC, the compressive strength and tensile strength of RECC were significantly reduced. Despite these reductions, all the mixture achieved its minimum acceptable compressive strength of 35 MPa, and tensile strength is 2.31MPa. The ideal percentage of crumb rubber as partial sand replacement in ECC or RECC is 5%. However, more extensive tests can be conducted in the future to determine the flexural strength of different percentages of crumb rubber.
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 849 (1)
Cyclic Behaviour of Beam-Column Joints with Corbels Under In-Plane Lateral Loads
Corbels appearance in precast beam-column joints has a significant impact on the behaviour of the transition zone at the end of the beam which could help in delaying the yielding of the top reinforcement bars and increase the stiffness of the joint. The presence of corbels also released the development of unnecessary strain at the top of the internal reinforcement bars. Hence, the main objective of this paper is to access the emulative approach for beam-column joints with corbels in terms of structural behaviour for any seismic action through experimental work. Comparison of the experimental hysteresis loops (load versus displacement) and seismic performance for the three types of joints were made. Three full-scale sub-assemblages of corner, exterior and interior precast beam-column joints with corbel were designed using BS8110 Code of Practice. These three specimens were constructed and tested in a heavy structural laboratory under in-plane lateral cyclic loading. The corner, exterior and interior beam-column joints were tested starting from ±0.01% until 1.35% drift, ±1.00% drift and ±1.15% drift, respectively. This study found that the existence of corbels in precast joints can delay the yielding of the top reinforcement bars and increase the stiffness of the joint. However, the experimental result has proved that the corbel for corner beam-column joint was the weakest point of the joint based on the crack damaged at the corbel. On the other hand, the experimental work found that precast beam-column corner joint specimen exhibited 21.5% more ductile behaviour as compared to other two specimens. However, the ductility values for all specimens were recorded at less than 3, indicating that precast beam-column joint specimens were not able to take moderate to strong earthquake excitation.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 849 (1)
Open AccessCyclic Behaviour of Beam-Column Joints with Corbels Under In-Plane Lateral Loads
Corbels appearance in precast beam-column joints has a significant impact on the behaviour of the transition zone at the end of the beam which could help in delaying the yielding of the top reinforcement bars and increase the stiffness of the joint. The presence of corbels also released the development of unnecessary strain at the top of the internal reinforcement bars. Hence, the main objective of this paper is to access the emulative approach for beam-column joints with corbels in terms of structural behaviour for any seismic action through experimental work. Comparison of the experimental hysteresis loops (load versus displacement) and seismic performance for the three types of joints were made. Three full-scale sub-assemblages of corner, exterior and interior precast beam-column joints with corbel were designed using BS8110 Code of Practice. These three specimens were constructed and tested in a heavy structural laboratory under in-plane lateral cyclic loading. The corner, exterior and interior beam-column joints were tested starting from ±0.01% until 1.35% drift, ±1.00% drift and ±1.15% drift, respectively. This study found that the existence of corbels in precast joints can delay the yielding of the top reinforcement bars and increase the stiffness of the joint. However, the experimental result has proved that the corbel for corner beam-column joint was the weakest point of the joint based on the crack damaged at the corbel. On the other hand, the experimental work found that precast beam-column corner joint specimen exhibited 21.5% more ductile behaviour as compared to other two specimens. However, the ductility values for all specimens were recorded at less than 3, indicating that precast beam-column joint specimens were not able to take moderate to strong earthquake excitation.
- Open Access
- 1 April 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 476 (1)
Investigation of prestressed concrete sleeper’s vibration located at KM71.75 And KM79
Train has been one of the essential and convenient transportation choices for community nowadays. Instead of carrying a passenger, these types of facilities also can be used to transport material across our country. With the increasing usage of train every year, the rate of accidents has also increased dramatically. Therefore, the importance of studying about the railway can contribute to building better and comfort railway track which can deliver their services at its best for an extended period. This study focused on the measurement of the deflection of concrete sleepers which affect the performance of the railway track. Lack of actual deflection value from the site can be problematic to ensure the quality of the track itself. The method used for the analysis is by using the Sirius-M instrument which can be recorded and analyses the acceleration of the concrete sleepers when receiving the loading wave from a moving train. The data of acceleration then can be transformed into deflection form by applying double integration. From the data collection, it shows that the maximum deflection at northbound at KM79 is 13.72 mm for freight train and 1.5 mm at southbound for six set commuter train. As for KM 71.75, the maximum deflection at northbound is 0.57mm for ETS and 1.5mm at southbound for six set commuter train. Thus, from this research, the actual deflection value from both sites were achieved.
- 1 April 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 476 (1)
Open AccessInvestigation of prestressed concrete sleeper’s vibration located at KM71.75 And KM79
Train has been one of the essential and convenient transportation choices for community nowadays. Instead of carrying a passenger, these types of facilities also can be used to transport material across our country. With the increasing usage of train every year, the rate of accidents has also increased dramatically. Therefore, the importance of studying about the railway can contribute to building better and comfort railway track which can deliver their services at its best for an extended period. This study focused on the measurement of the deflection of concrete sleepers which affect the performance of the railway track. Lack of actual deflection value from the site can be problematic to ensure the quality of the track itself. The method used for the analysis is by using the Sirius-M instrument which can be recorded and analyses the acceleration of the concrete sleepers when receiving the loading wave from a moving train. The data of acceleration then can be transformed into deflection form by applying double integration. From the data collection, it shows that the maximum deflection at northbound at KM79 is 13.72 mm for freight train and 1.5 mm at southbound for six set commuter train. As for KM 71.75, the maximum deflection at northbound is 0.57mm for ETS and 1.5mm at southbound for six set commuter train. Thus, from this research, the actual deflection value from both sites were achieved.
- 29 November 2019
- Published by Springer Nature
- p. 749-760
Seismic Performance of Reinforced Concrete Residential Building Modeled Using Ruaumoko2D Program
- 29 November 2019
- Published by Springer Nature
- p. 749-760
Seismic Performance of Reinforced Concrete Residential Building Modeled Using Ruaumoko2D Program
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1349 (1)
Investigation on the behaviour of prestressed concrete sleepers (PCS) under negative static loading
Railways in Malaysia are undoubtedly a various incorporated element that can possibly assume as an imperative part in the advancement of a manageable transportation framework in the nation. Therefore, failure of prestressed concrete sleepers under the negative static loading need to be investigate due to its role as one of the important part in railway. In this study, negative moment test was established to investigate the design load of the prestressed concrete sleeper (PCS) under negative static loading. Three (3) samples of PCS were used and one (1) PCS contains two rail seat, called KTMB and EPMI sides. It is found that new crack appeared on EPMI sides with the length of 100 millimeters. Meanwhile, the highest displacement for EPMI and KTMB sides were found to be 7.332 and 6.606 millimeters. From three (3) samples tested, only one PCS shows the failure to cater the design load of 176.94 kN subjected to rail seat.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1349 (1)
Open AccessInvestigation on the behaviour of prestressed concrete sleepers (PCS) under negative static loading
Railways in Malaysia are undoubtedly a various incorporated element that can possibly assume as an imperative part in the advancement of a manageable transportation framework in the nation. Therefore, failure of prestressed concrete sleepers under the negative static loading need to be investigate due to its role as one of the important part in railway. In this study, negative moment test was established to investigate the design load of the prestressed concrete sleeper (PCS) under negative static loading. Three (3) samples of PCS were used and one (1) PCS contains two rail seat, called KTMB and EPMI sides. It is found that new crack appeared on EPMI sides with the length of 100 millimeters. Meanwhile, the highest displacement for EPMI and KTMB sides were found to be 7.332 and 6.606 millimeters. From three (3) samples tested, only one PCS shows the failure to cater the design load of 176.94 kN subjected to rail seat.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1349 (1) , 012044
Damage detection of artificial corroded rebars and quantification using non-destructive methods on reinforced concrete structure
Corrosion of rebars in reinforced concrete structure is a big universal problem created by saline water ingress causing rebar and other metal structural member to corrode. The deterioration of concrete structures due to the harsh environment conditions leads to the deterioration of the reinforced concrete performance structure, and the premature deterioration of the structure before completing due to carbonation or the chloride content of the future services is expected to be the primary concern for engineers and researchers. Progress of corrosion location cannot be visually evaluated until the point when crack or a delamination is appearing. Therefore, in the study, the Ground Penetrating Radar (GPR) is used to investigate the artificial rebar corrosion damage on steel rebars. The methods showed the artificial rebar corrosion damage can be detected and quantified without damaging the surrounding concrete material. GPR showed the potential on detecting rebar corrosion damage on large areas and in a rapid manner.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1349 (1) , 012044
Open AccessDamage detection of artificial corroded rebars and quantification using non-destructive methods on reinforced concrete structure
Corrosion of rebars in reinforced concrete structure is a big universal problem created by saline water ingress causing rebar and other metal structural member to corrode. The deterioration of concrete structures due to the harsh environment conditions leads to the deterioration of the reinforced concrete performance structure, and the premature deterioration of the structure before completing due to carbonation or the chloride content of the future services is expected to be the primary concern for engineers and researchers. Progress of corrosion location cannot be visually evaluated until the point when crack or a delamination is appearing. Therefore, in the study, the Ground Penetrating Radar (GPR) is used to investigate the artificial rebar corrosion damage on steel rebars. The methods showed the artificial rebar corrosion damage can be detected and quantified without damaging the surrounding concrete material. GPR showed the potential on detecting rebar corrosion damage on large areas and in a rapid manner.
- Open Access
- 15 October 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 615 (1) , 012123
The behaviour of Prestressed Concrete Sleeper (pcs) sitting on railway track
Prestressed concrete sleeper (PCS) is one of the important components for railway structural system. PCS sits on ballast (ground) and the load from the train wheel will be transferred through it thus distributed to the ground. In Malaysia, the ground condition from one place to another is unique. If the PCS sits on an uneven or unstable ground base, the load from the train may not be transferred smoothly to the ground and when that happened, the PCS might be damaged or broken into half. In this research, the researchers, with the help of the Keretapi Tanah Melayu Berhad (KTMB) personnel, studied about some problematic PCS that sit on an uneven ground base. By using the state-of-the-art on-site equipment, results were obtained and strengthened the KTMB assumption on their problematic sites. The data collection shows that the value of deflection is higher at KM20.75 compared to KM26.25 which is 18.90mm and 1.48mm respectively for 6-coach commuter and 8.45mm and 1.36mm respectively for Electric Train Service (ETS). This result may be affected by the existence void under the rail track structure at KM20.75 due to soil settlement caused by the underground water stream.
- 15 October 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 615 (1) , 012123
Open AccessThe behaviour of Prestressed Concrete Sleeper (pcs) sitting on railway track
Prestressed concrete sleeper (PCS) is one of the important components for railway structural system. PCS sits on ballast (ground) and the load from the train wheel will be transferred through it thus distributed to the ground. In Malaysia, the ground condition from one place to another is unique. If the PCS sits on an uneven or unstable ground base, the load from the train may not be transferred smoothly to the ground and when that happened, the PCS might be damaged or broken into half. In this research, the researchers, with the help of the Keretapi Tanah Melayu Berhad (KTMB) personnel, studied about some problematic PCS that sit on an uneven ground base. By using the state-of-the-art on-site equipment, results were obtained and strengthened the KTMB assumption on their problematic sites. The data collection shows that the value of deflection is higher at KM20.75 compared to KM26.25 which is 18.90mm and 1.48mm respectively for 6-coach commuter and 8.45mm and 1.36mm respectively for Electric Train Service (ETS). This result may be affected by the existence void under the rail track structure at KM20.75 due to soil settlement caused by the underground water stream.
- 5 October 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2020 (1) , 020019
A review: Soil structure interaction of railway structure in Malaysia permanent way
The upgrading of the Northern-Southern Railway Line to accommodate for future High Speed Rail (HSR) soon to be constructed. The nature of soil between places are varied thus create a problems for railway engineers to lay down Prestressed Concrete Sleeper (PCS). Soil-structure interaction is very important to ensure any structure stand and distribute the load to ground. A lot of cases has been reported due to low soil-structure interaction. The sign of a low soil structure interaction can be seen in short or longer period of time. PCS were located directly above ground and if the soil-structure interaction is low, the result will be catastrophic. There have been reported that certain rail track line were located at a problematic soil (settlement) and the rail engineer have to monitor the situation on regular basis. Hence, this research aims to understand more about the relationship between the PCS and soil thus creating awareness to relevant authorities to tackle this problem.
- 5 October 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2020 (1) , 020019
A review: Soil structure interaction of railway structure in Malaysia permanent way
The upgrading of the Northern-Southern Railway Line to accommodate for future High Speed Rail (HSR) soon to be constructed. The nature of soil between places are varied thus create a problems for railway engineers to lay down Prestressed Concrete Sleeper (PCS). Soil-structure interaction is very important to ensure any structure stand and distribute the load to ground. A lot of cases has been reported due to low soil-structure interaction. The sign of a low soil structure interaction can be seen in short or longer period of time. PCS were located directly above ground and if the soil-structure interaction is low, the result will be catastrophic. There have been reported that certain rail track line were located at a problematic soil (settlement) and the rail engineer have to monitor the situation on regular basis. Hence, this research aims to understand more about the relationship between the PCS and soil thus creating awareness to relevant authorities to tackle this problem.