ASAhmed Farag Seddik

Ahmed Farag Seddik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Farag Seddik has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigating Relationship Between Lateral Time-To-Peak (TTP) Displacement Curves and Stiffness of Viscoelastic Agar-Gelatin Phantoms

    by Hassan M. Ahmed, Nancy M. Salem, Ahmed F. Seddik, Mohamed I. El-Adawy

    Shear wave speed is a metric for the tissue elastic properties and its pathologic changes. This is due to the implicit relationship between the speed of the propagating shear wave within tissue and both its elastic properties and pathologic changes. Wave propagation is a result of a force applied transiently to the tissue model. In this paper, the relationship between lateral TTP displacement curves and stiffness of different Young's moduli phantoms is investigated. Five different elastic moduli Finite Element Models (FEMs) are used; 5.2KPa, 9.8KPa, 23.9KPa, 44.2KPa and 67.3KPa. Agar-gelatin model is used as a general model for mimicking soft tissue. Displacements are tracked with respect to the simulation time to create the displacement magnitude profile for the central node for each phantom. Results have shown that the second highest peak happens after 0.05 seconds in case of low elastic moduli FEMs. This time stamp can be used as a yardstick to differentiate between low and high elastic moduli without considering estimating the shear wave speed for many lateral nodes.


  • Fuzzy Logic Approach For Medical Equipment Supplier Evaluation and Selection

    by Mohamed E. Ragheb, Mohammed A. Hassan, Walid I. Al-Atabany, Ahmed F. Seddik, Mohamed T. El-Wakad

    One of the most critical activities in the management of purchasing process is supplier selection which is a decision making activity characterized by being a multi-criteria based activity. This paper proposes a multi-criteria fuzzy based system to create a short listing of the most suitable suppliers. Only the members of this short listing would be allowed to request for offers in a tender. The proposed system uses three main criteria and twenty sub-criteria. Dataset collected from five different companies is used to validate the system against experts' opinions. Results show the robustness of the proposed system in creating a short listing for the most suitable medical suppliers with an average error of 4.45 ± 4.06.


  • Impedance Analysis of Different Shapes of the Normal and Malignant White Blood Cells

    by Sameh Sherif, Yehya H. Ghallab, Ahmed Seddik, Hamdy Abdelhamid, Yehea Ismail

    In this paper, a 3d numerical study for double shell leukemia cell impedance is presented. A capacitive sensing based technique is used to extract the cell's Clausius-Mossotti factor. The spherical and non-spherical shapes are considered in this work. We found the impedance of non-spherical leukemia shape is higher than the spherical leukemia shape. Also, a full study of impedance for different shapes of normal and malignant white blood cell using numerical simulators is presented and discussed. Moreover, the location of the cell over the sensing electrodes is considered to extract the exact impedance value.


  • Low cost portable blood urea nitrogen analyzer using Odroid system

    by Mina S. A. Saleh, Ahmed Agamieh, Ahmed F. Seddik, Yehya H. Ghallab

    Early detection of diseases reduces the cost of treatment and in some chronic diseases there is a need to follow-up and to make daily blood analysis, so the patient should go to the laboratories where the devices are huge in size and high cost. To solve this problem, a cheap analyzer that is small size and easy to use is needed to be next to the patient. For this reason, a point-of-care (POC) diagnostics device is innovated with small size, low cost and easy to use based on the Odroid technology which automatically analyses color changes in Vitros dry-slide that is sensitive with specific detection for measuring the proportion of blood urea nitrogen (BUN) with results close to existing devices.

  • Open Access

    Cloud Based Low Cost Retinal Detachment Screening Method Using Data Mining Techniques

    by Mahmoud A. Fakhreldin, Ahmed F. Seddik

    The Electro-Oculogram (EOG) signal can be used for detecting the normality of the eye retina. A number of advantages including the flexibility of the recoding process for EOG signals have encouraged insight into EOG based research. This study proposes a new cloud based retinal detachment screening technique based on data mining techniques to diagnose the type of eye retina. The used recognition methods include: back propagation neural network, Kohonen neural network and support vector machine. The obtained results are classified as normal or abnormal eye retina. Given a training set of such patterns, the proposed system is trained how to differentiate a new case in the domain. The diagnosis performance of the proposed systems is evaluated using more than one performance measure such as statistical accuracy, specificity and sensitivity. The diagnostic accuracy of the proposed neural network has achieved a remarkable performance with 100% accuracy on training and test subsets. The main advantage of the proposed system is the high quality of the diagnosis process that help health team to take the suitable decision regarding the patient case. The proposed system may help reducing the cost of screening patients especially in rural areas where experts are not available through sending their data to a central site where the automatic system will help an expert to diagnose the suspected cases.

  • An improved planar electrode for dielectric parameters extraction

    by Sameh Sherif, Yehya H. Ghallab, Hamdy Abdelhamid, Ahmed Seddik, Yehea Ismail

    Detection dielectric properties of a biological cell as a function of frequency sweeping is very important, this response can be used to define different information like a chemical, physical or kinetic properties. We analyzed the cell by its conductance and capacitance. This paper presents a numerical study for the capacitance and the conductance based on asymmetric electrodes (AE) configuration compared with a 2D planar electrode are presented. We found the AE configuration improves the sensitivity of the measured capacitance and conductance. Also, a comparison with different cell shapes is simulated using the proposed AE. The simulation shows that there is a difference in a both capacitance and conductance based on the cell shape.

  • Development of a Wireless Safety Helmet Mobile APP Using EEG Signal Analysis

    by A. S. Abdel-Rahman, A. F. Seddik, D. M. Shawky

    International Journal of Signal Processing Systems (IJSPS)


  • Open Access

    Automatic Segmentation and Classification of Masses from Digital Mammograms

    by Basma A. Mohamed, Nancy M Salem, Marwa M Hadhoud, Ahmed F Seddik

    Breast cancer is one of the leading causes of death among female cancer patients. Mammography is the most efficient method for the early detection of abnormalities that are associated with breast cancer. Masses and micro calcifications are the most popular abnormalities that indicate breast cancer. The proposed paper intends to develop an automated system for assisting the analysis of digital mammograms. First, a preprocessing step is applied to enhance images followed by a segmentation step that is based on morphological operations and Otsu’s thresholding techniques. Thereafter, shape features are extracted from the segmented region and used in the classification process. Finally, the classification step to classify the segmented shape as round, oval, lobular, or irregular. The algorithm is tested using 270 mammogram images from the Women Health Care Program (WHC) and 142 publicly available images from the Digital Database for Screening Mammography (DDSM). Results show that the proposed technique effectively detects and segments masses from mammogram images. The shape of segmented masses is classified into either round, oval, lobular, or irregular. Round and oval shapes are classified with 100% accuracy while lobular and irregular shapes results in accuracy of 93% using the ANN for the WHC dataset and 100%. On the other hand, accuracy for images from the DDSM is 100% and 91.3% respectively.


  • Logistic regression model for breast cancer automatic diagnosis

    by Ahmed F. Seddik, Doaa M. Shawky

    Breast cancer is the uncontrolled growth of breast cells. It represents the second cause of cancer death in women worldwide. It is important for patients to understand their disease and know what to expect in the future so that they can make decisions about treatment, rehabilitation, financial aid decisions and personal matters. This paper presents an approach for diagnosing breast cancer based on a set of input variables that describe some characteristics of tumor images. The proposed approach builds a binary logistic model that classifies between malignant and benign cases. The approach is applied to the Wisconsin Diagnostic Breast Cancer (WDBC) dataset. Experimental results show that the regression model that is statistically significant includes only the area, texture, concavity and symmetry features of a tumor. In addition to the simplicity of the used model, the reduced set of features gives performance measures that outperform similar approaches. Accordingly, the presented approach can be used for feature selection and reduction of the breast cancer data.