Ziyaetdin M. Uteshev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ziyaetdin M. Uteshev has a total of 672 co-authors. Here are the top co-authors by number of shared publications:
- Konstantin F. Vlasik
National Research Nuclear Univ. MEPhI (Russian Federation)
69 shared publications - Valeriy V. Dmitrenko
National Research Nuclear Univ. MEPhI (Russian Federation)
69 shared publications - Sergey E. Ulin
National Research Nuclear University MEPhI, Moscow, Russia
66 shared publications - Alexander E. Shustov
National Research Nuclear University «MEPhI
39 shared publications - Alexander Novikov
Department of Physics and Astronomy, University of Delaware, Newark, DE 19716
37 shared publications V. M. Grachev
National Research Nuclear University “MEPhI”, 115409, Moscow, Russia
19 shared publications
Latest Publications
- 1 June 2020
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 47 (6) , 176-180
Gamma Spectrometry System for Decommissioning Nuclear Facilities
The structure of gamma spectrometry systems for decommissioning nuclear facilities is considered. Physicotechnical characteristics of a xenon gamma spectro
- 1 June 2020
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 47 (6) , 176-180
Gamma Spectrometry System for Decommissioning Nuclear Facilities
The structure of gamma spectrometry systems for decommissioning nuclear facilities is considered. Physicotechnical characteristics of a xenon gamma spectro
- 9 September 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11114, 19
Xenon gamma-ray spectrometers: development and applications
The description of xenon gamma-ray spectrometers is presented. These devices can be produced with various sensitive volumes (0.2 – 6.0 liters), they provide high energy resolution (~2% at 662 keV) and are capable of operation in unfavorable conditions (wide temperature range and high level of vibro-acoustic influence). Xenon gamma-ray spectrometers can be used for various fundamental and applied tasks, the outcomes of those applications and the prospect of the detector utilization in various fields are also presented.
- 9 September 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11114, 19
Xenon gamma-ray spectrometers: development and applications
The description of xenon gamma-ray spectrometers is presented. These devices can be produced with various sensitive volumes (0.2 – 6.0 liters), they provide high energy resolution (~2% at 662 keV) and are capable of operation in unfavorable conditions (wide temperature range and high level of vibro-acoustic influence). Xenon gamma-ray spectrometers can be used for various fundamental and applied tasks, the outcomes of those applications and the prospect of the detector utilization in various fields are also presented.
- Open Access
- 9 April 2019
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2019 (4) , 77
Sensitivity of the SHiP experiment to Heavy Neutral Leptons
Heavy Neutral Leptons (HNLs) are hypothetical particles predicted by many extensions of the Standard Model. These particles can, among other things, explain the origin of neutrino masses, generate the observed matter-antimatter asymmetry in the Universe and provide a dark matter candidate. The SHiP experiment will be able to search for HNLs produced in decays of heavy mesons and travelling distances ranging between $$ \mathcal{O} $$ (50 m) and tens of kilometers before decaying. We present the sensitivity of the SHiP experiment to a number of HNL’s benchmark models and provide a way to calculate the SHiP’s sensitivity to HNLs for arbitrary patterns of flavour mixings. The corresponding tools and data files are also made publicly available.- 9 April 2019
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2019 (4) , 77
Open AccessSensitivity of the SHiP experiment to Heavy Neutral Leptons
Heavy Neutral Leptons (HNLs) are hypothetical particles predicted by many extensions of the Standard Model. These particles can, among other things, explain the origin of neutrino masses, generate the observed matter-antimatter asymmetry in the Universe and provide a dark matter candidate. The SHiP experiment will be able to search for HNLs produced in decays of heavy mesons and travelling distances ranging between $$ \mathcal{O} $$ (50 m) and tens of kilometers before decaying. We present the sensitivity of the SHiP experiment to a number of HNL’s benchmark models and provide a way to calculate the SHiP’s sensitivity to HNLs for arbitrary patterns of flavour mixings. The corresponding tools and data files are also made publicly available. - Open Access
- 1 March 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (03) , P03025
The experimental facility for the Search for Hidden Particles at the CERN SPS
- 1 March 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (03) , P03025
Open AccessThe experimental facility for the Search for Hidden Particles at the CERN SPS
- 13 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10762, 20
Anticoincidence scintillation detector for the Signal experiment onboard the spacecraft Interhelioprobe
Measurement results of charged particles (atmospheric muon) detection efficiency of a scintillation detector based on polyvinyltoluene, manufactured for the anticoincidence system of the "Signal" device as part of the scientific apparatus for the spacecraft "Interhelioprobe", are presented. The efficiency measurement technique is based on determination of the ratio of triple and double coincidence of the signals arising as atmospheric mu-mesons pass through the system of detectors. The results of light collection simulation in scintillation detectors by the use of Monte Carlo method are presented.
- 13 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10762, 20
Anticoincidence scintillation detector for the Signal experiment onboard the spacecraft Interhelioprobe
Measurement results of charged particles (atmospheric muon) detection efficiency of a scintillation detector based on polyvinyltoluene, manufactured for the anticoincidence system of the "Signal" device as part of the scientific apparatus for the spacecraft "Interhelioprobe", are presented. The efficiency measurement technique is based on determination of the ratio of triple and double coincidence of the signals arising as atmospheric mu-mesons pass through the system of detectors. The results of light collection simulation in scintillation detectors by the use of Monte Carlo method are presented.
- 1 September 2018
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 81 (5) , 630-633
Efficiency Of Charged-Particle Detection with Scintillation-Detector Prototype for the Anticoincidence System of the Signal Experiment
The results obtained by measuring the efficiency of detection of charged particles (atmospheric muons) for a prototype of a polyvinyltoluene-based scintillation detector being created for the...
- 1 September 2018
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 81 (5) , 630-633
Efficiency Of Charged-Particle Detection with Scintillation-Detector Prototype for the Anticoincidence System of the Signal Experiment
The results obtained by measuring the efficiency of detection of charged particles (atmospheric muons) for a prototype of a polyvinyltoluene-based scintillation detector being created for the...
- Open Access
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (05) , P05011
The active muon shield in the SHiP experiment
The SHiP experiment is designed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. An essential task for the experiment is to keep the Standard Model background level to less than 0.1 event after 2× 1020 protons on target. In the beam dump, around 1011 muons will be produced per second. The muon rate in the spectrometer has to be reduced by at least four orders of magnitude to avoid muon-induced combinatorial background. A novel active muon shield is used to magnetically deflect the muons out of the acceptance of the spectrometer. This paper describes the basic principle of such a shield, its optimization and its performance.
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (05) , P05011
Open AccessThe active muon shield in the SHiP experiment
The SHiP experiment is designed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. An essential task for the experiment is to keep the Standard Model background level to less than 0.1 event after 2× 1020 protons on target. In the beam dump, around 1011 muons will be produced per second. The muon rate in the spectrometer has to be reduced by at least four orders of magnitude to avoid muon-induced combinatorial background. A novel active muon shield is used to magnetically deflect the muons out of the acceptance of the spectrometer. This paper describes the basic principle of such a shield, its optimization and its performance.
- 1 March 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (2) , 175-181
The RED-100 two-phase emission detector
The RED-100 experimental setup, which is designed to detect elastic coherent neutrino scattering off xenon nuclei, is described. One specific feature of this setup is the possibility of using it in...
- 1 March 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (2) , 175-181
The RED-100 two-phase emission detector
The RED-100 experimental setup, which is designed to detect elastic coherent neutrino scattering off xenon nuclei, is described. One specific feature of this setup is the possibility of using it in...
- Open Access
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 798 (1) , 012139
Characteristics of magnetic shields for protection PMT in the LHCb hadron calorimeter
CERN is preparing the new experiment aimed at the detection of weakly interacting massive long-lived particles. The experiment was called SHiP. The instrumental and technological solutions successfully used in experimental setups ATLAS, LHCb and others will be applied in experimental setup SHiP. One of these units is a hadrons calorimeter. It uses several thousands photomultiplier tubes (PMT) placed in protective magnetic shields because PMTs are located near strong permanent magnets. Taking into account that since the creation of the experimental setup LHCb has been passed more than 10 years and there are new manufacturing techniques of magnetic screens appeared, we investigate the characteristics of shielding screens used in the LHCb, and proposed the recommendations to magnetic screens' designs for SHiP experiment.
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 798 (1) , 012139
Open AccessCharacteristics of magnetic shields for protection PMT in the LHCb hadron calorimeter
CERN is preparing the new experiment aimed at the detection of weakly interacting massive long-lived particles. The experiment was called SHiP. The instrumental and technological solutions successfully used in experimental setups ATLAS, LHCb and others will be applied in experimental setup SHiP. One of these units is a hadrons calorimeter. It uses several thousands photomultiplier tubes (PMT) placed in protective magnetic shields because PMTs are located near strong permanent magnets. Taking into account that since the creation of the experimental setup LHCb has been passed more than 10 years and there are new manufacturing techniques of magnetic screens appeared, we investigate the characteristics of shielding screens used in the LHCb, and proposed the recommendations to magnetic screens' designs for SHiP experiment.
- Open Access
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 798 (1) , 012145
Identification of radionuclides using energy spectra of xenon gamma-ray spectrometer
Software tool for identification of radionuclides using energy spectra of xenon gamma-ray spectrometer was developed. Software tool includes the build-in gamma-ray library and allows to perform the qualitative and quantitative isotopes analysis of gamma-ray spectra.
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 798 (1) , 012145
Open AccessIdentification of radionuclides using energy spectra of xenon gamma-ray spectrometer
Software tool for identification of radionuclides using energy spectra of xenon gamma-ray spectrometer was developed. Software tool includes the build-in gamma-ray library and allows to perform the qualitative and quantitative isotopes analysis of gamma-ray spectra.