Yushu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yushu Liu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Rui Zhang
Department of Prosthodontics Stomatology Center Peking University Shenzhen Hospital Shenzhen PR China
2 shared publications- Xinyue Cui
Department of Dentistry Beijing Jishuitan Hospital Capital Medical University Beijing PR China
2 shared publications Chang-Feng Niu
School of Computer Science and Technology, Beijing Institute of Technology, Beijing, China
1 shared publication- Chi Fai Cheung
The Hong Kong Polytechnic University
1 shared publication - Dan Li
Department of Chemical Engineering The University of Melbourne Parkville VIC 3082 Australia
1 shared publication Duo Chen
Institute of Computer Science and Technology Peking University Beijing PR China
1 shared publication
Latest Publications
- 30 October 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 34 (4) , 382-387
Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core
Purpose: This in vitro study aimed to compare the 3‐dimensional (3D) accuracy of intraoral and desktop scanners when digitizing the post and core polyvinyl siloxane impressions.Material and Methods: Ten extracted human teeth were prepared to build a post space in the root canal. Each tooth was scanned using a micro‐computed tomography device (MCT), and the slice data were reconstructed as controls. A conventional quadrant polyvinyl siloxane impression was made and scanned thrice using an intraoral scanner (IOS) and a desktop blue‐light scanner (IMS), with one of the scans randomly selected as the definitive cast. Precision was assessed by comparing the deviations among repeated scans. Trueness was evaluated by analyzing the deviations between the MCT and each definitive cast (MCT‐IOS and MCT‐IMS). The clinically acceptable root mean square (RMS) value was set to 50 µm.Results: The mean RMS values of the repeated scans of IOS and IMS were 18.3 ± 3.9 µm and 13.9 ± 6.2 µm (P < 0.05), and the difference between them was 4.4 ± 5.9 µm. The mean RMS values of MCT‐IOS and MCT‐IMS were 28.3 ±3.0 µm and 31.3 ± 4.2 µm (P < 0.05), with a difference of 3.0 ± 2.9 µm. The RMS values were significantly lower than 50 µm (P < 0.05).Conclusions: The IOS showed slightly better trueness than the IMS but slightly lower precision. The precision and trueness of the two scanners for digitizing post and core impressions were acceptable for clinical application.
- 30 October 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 34 (4) , 382-387
Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core
Purpose: This in vitro study aimed to compare the 3‐dimensional (3D) accuracy of intraoral and desktop scanners when digitizing the post and core polyvinyl siloxane impressions.Material and Methods: Ten extracted human teeth were prepared to build a post space in the root canal. Each tooth was scanned using a micro‐computed tomography device (MCT), and the slice data were reconstructed as controls. A conventional quadrant polyvinyl siloxane impression was made and scanned thrice using an intraoral scanner (IOS) and a desktop blue‐light scanner (IMS), with one of the scans randomly selected as the definitive cast. Precision was assessed by comparing the deviations among repeated scans. Trueness was evaluated by analyzing the deviations between the MCT and each definitive cast (MCT‐IOS and MCT‐IMS). The clinically acceptable root mean square (RMS) value was set to 50 µm.Results: The mean RMS values of the repeated scans of IOS and IMS were 18.3 ± 3.9 µm and 13.9 ± 6.2 µm (P < 0.05), and the difference between them was 4.4 ± 5.9 µm. The mean RMS values of MCT‐IOS and MCT‐IMS were 28.3 ±3.0 µm and 31.3 ± 4.2 µm (P < 0.05), with a difference of 3.0 ± 2.9 µm. The RMS values were significantly lower than 50 µm (P < 0.05).Conclusions: The IOS showed slightly better trueness than the IMS but slightly lower precision. The precision and trueness of the two scanners for digitizing post and core impressions were acceptable for clinical application.
- Open Access
- 26 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105348
The accuracy of a novel 3D digital evaluation method of intraoral fitness for removable partial dentures
- 26 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105348
Open AccessThe accuracy of a novel 3D digital evaluation method of intraoral fitness for removable partial dentures
- Open Access
- 23 December 2021
- Published by Elsevier in Journal of Dental Sciences
- Vol. 17 (3) , 1212-1216
Polymerization shrinkage and shrinkage stress of bulk-fill and non-bulk-fill resin-based composites
- 23 December 2021
- Published by Elsevier in Journal of Dental Sciences
- Vol. 17 (3) , 1212-1216
Open AccessPolymerization shrinkage and shrinkage stress of bulk-fill and non-bulk-fill resin-based composites
- 21 December 2021
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 34 (5) , 759-762
A method of fabricating computer aided design‐computer aided manufacturing implant‐supported provisional restorations with clear aligner attachments: A technical report
Objective: To provide a method of fabricating implant‐supported provisional restorations with orthodontic attachments by digital technique.Clinical consideration: Polymethylmethacrylate (PMMA) provisional restorations are usually necessary when dental implants are serving as anchors for orthodontic treatments. For clear aligner treatment, it is possible to setup the teeth virtually and determine the final position of the implants, indicating that the provisional restorations can be also predetermined. However, attachments on PMMA restorations have a higher risk of debonding due to low bond strength. To fabricate provisional restorations with predetermined shape and position and no risk of attachment debonding immediately after implant placement, a digital workflow is introduced in this article.Conclusions: By combining “pick‐up” technique and prefabricated monolithic PMMA provisional restorations, this technique is recommended for making implant‐supported provisional restorations with integrated orthodontic attachments based on the digitally designed positions of the teeth.Clinical significance: The present protocol describes a digital workflow of designing and manufacturing implant‐supported PMMA provisional restorations with orthodontic attachments in the predetermined position of implants, which should lead to more reliable and predictable orthodontic treatment outcomes.
- 21 December 2021
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 34 (5) , 759-762
A method of fabricating computer aided design‐computer aided manufacturing implant‐supported provisional restorations with clear aligner attachments: A technical report
Objective: To provide a method of fabricating implant‐supported provisional restorations with orthodontic attachments by digital technique.Clinical consideration: Polymethylmethacrylate (PMMA) provisional restorations are usually necessary when dental implants are serving as anchors for orthodontic treatments. For clear aligner treatment, it is possible to setup the teeth virtually and determine the final position of the implants, indicating that the provisional restorations can be also predetermined. However, attachments on PMMA restorations have a higher risk of debonding due to low bond strength. To fabricate provisional restorations with predetermined shape and position and no risk of attachment debonding immediately after implant placement, a digital workflow is introduced in this article.Conclusions: By combining “pick‐up” technique and prefabricated monolithic PMMA provisional restorations, this technique is recommended for making implant‐supported provisional restorations with integrated orthodontic attachments based on the digitally designed positions of the teeth.Clinical significance: The present protocol describes a digital workflow of designing and manufacturing implant‐supported PMMA provisional restorations with orthodontic attachments in the predetermined position of implants, which should lead to more reliable and predictable orthodontic treatment outcomes.
- 8 November 2021
- Published by Wiley in Journal of Prosthodontics
- Vol. 31 (2) , 171-174
The Application of 3D Dense Face Alignment in Esthetic Rehabilitation
This article describes a technique for making an esthetic treatment plan by using a virtual face scan reconstructed from digital photographs through three‐dimensional dense face alignment (3DDFA) and intraoral scans. Portrait photographs were captured with a digital camera and were reconstructed to a virtual 3D face scan by 3DDFA. After scaling the virtual face scan to the correct size, intraoral scans and virtual face scans were aligned to create a 3D view of the patient. A virtual diagnostic waxing was created accordingly. In select cases, this technique can provide 3D esthetic predictions when 3D face imaging devices are not available.
- 8 November 2021
- Published by Wiley in Journal of Prosthodontics
- Vol. 31 (2) , 171-174
The Application of 3D Dense Face Alignment in Esthetic Rehabilitation
This article describes a technique for making an esthetic treatment plan by using a virtual face scan reconstructed from digital photographs through three‐dimensional dense face alignment (3DDFA) and intraoral scans. Portrait photographs were captured with a digital camera and were reconstructed to a virtual 3D face scan by 3DDFA. After scaling the virtual face scan to the correct size, intraoral scans and virtual face scans were aligned to create a 3D view of the patient. A virtual diagnostic waxing was created accordingly. In select cases, this technique can provide 3D esthetic predictions when 3D face imaging devices are not available.
- 11 June 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (2) , 267-270
Assessing the accuracy of fabricated implant surgical guides by reconstructing the implant position based on cone beam computed tomography images: A dental technique
- 11 June 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (2) , 267-270
Assessing the accuracy of fabricated implant surgical guides by reconstructing the implant position based on cone beam computed tomography images: A dental technique
- 1 January 2009
- Published by ASME International
- p. 517-524
Hierarchic Particle Swarm Optimization Based Target Tracking
- 1 January 2009
- Published by ASME International
- p. 517-524
Hierarchic Particle Swarm Optimization Based Target Tracking
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 198-202
Multi-agent based IDSS architecture and negotiation mechanism
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 198-202
Multi-agent based IDSS architecture and negotiation mechanism