Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juan David Romero-Ante has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Estudio preliminar: caracterización por ultrasonido de criogeles de PVA

    by Juan Sebatián Montenegro-Bravo, Alberto Rodríguez-Martínez, Juan David Romero-Ante, Miguel Ángel De la Casa-Lillo, Jose María Sabater-Navarro

    Tissue-mimicking materials are fundamental tools for calibration, validation, and training in ultrasound techniques, as they allow controlled experimental conditions comparable to biological tissues to be reproduced. In this work, polyvinyl alcohol (PVA) cryogels were fabricated with different concentrations of propylene glycol, incorporated as an additive through partial substitution of demineralized water, with the aim of adjusting their acoustic response. The samples were obtained by physical gelation through freeze--thaw cycles and were characterized in immersion, at 36.5 ºC, using ultrasound transducers. From the analysis of time-of-flight measurements, the longitudinal speed of sound was determined for each formulation. The results showed mean velocities ranging from 1578.5 to 1615.7 m/s after the fifth cycle, values compatible with those reported for various soft tissues. These findings constitute preliminary results for the selection of formulations and guide the development of new PVA--propylene glycol compositions with tunable acoustic properties for ultrasound-based biomedical applications.

  • Open Access

    Arquitectura BLE para registrar señales fisiológicas simultáneas en tiempo real

    by Marta Nadal-Herraiz, Juan David Romero-Ante, Sergio Lidón-Calvo, Daniel Alejandro Rodríguez-López, Julián David Rojas-Gravier, José María Sabater-Navarro

    Bluetooth Low Energy (BLE) technology is the first wireless solution that addresses the key challenges of monitoring medical data. However, issues such as uneven reception, channel congestion, and packet loss arise in scenarios involving simultaneous, real-time multi-connection. To mitigate these issues, we present a BLE architecture designed for simultaneously recording electrocardiogram (ECG) and photoplethysmography (PPG) signals. This architecture is based on organizing connection intervals and events, as well as incorporating a time offset. The system accounts for maximum transmission unit (MTU) limitations between two XIAO nRF52840 development modules, programmed in CircuitPython and integrated with PPG and ECG sensors, and a mobile or desktop receiving device. The results described in this paper demonstrate significant improvements in data integrity by coordinating communication between nodes and overcoming the limitations of unscheduled data acquisition.

  • Computational Comparison of AC and DC Excitation for Long-Term Electrodermal Activity (EDA) Recording Across Electrode Materials

    by Amir M. Karimi Forood, Juan David Romero-Ante, Jose Maria Sabater-Navarro, Hugo F. Posada-Quintero

  • Open Access

    Validación del uso de conductancia eléctrica para estimar la humedad en tejidos absorbentes

    by Juan David Romero Ante, Juan Sebastián Montenegro-Bravo, Daniel Alejandro Rodríguez-López, José María Vicente-Samper, Miguel Ángel De la Casa-Lillo, Alberto Rodríguez-Martínez

    Este trabajo presenta la validación de una metodología experimental para estimar el contenido de humedad en tejidos biológicos mediante la medición de conductancia eléctrica, con enfoque en aplicaciones clínicas como el monitoreo de hidratación o la detección de disfunciones sudomotoras. Para la validación inicial, se empleó un bloque de papel absorbente como material modelo, al que se aplicaron volúmenes controlados de agua mientras se registraban simultáneamente su masa y conductancia. La variación de masa permitió calcular el contenido de humedad en cada ciclo, y los resultados revelaron una correlación no lineal con la conductancia registrada. Esta relación se ajustó mediante un modelo polinomial de segundo grado, con un coeficiente de determinación R2=0,992. Los resultados respaldan tanto la solidez de la metodología como la eficacia del dispositivo electrónico para detectar variaciones de humedad de forma continua. Aunque el rango de humedad estuvo limitado por las propiedades del material, el sistema demuestra un alto potencial de aplicación en tejidos reales.

  • Open Access

    Feasibility Study of Using Alternating Current Excitation to Obtain Electrodermal Activity with a Wearable System

    by Juan David Romero-Ante, Juan Sebastián Montenegro-Bravo, José María Vicente-Samper, Vicente Manuel Esteve-Sala, Miguel Ángel de la Casa-Lillo, José María Sabater-Navarro

    This study investigates the feasibility of using a wearable system with full-wave alternating current (AC) excitation to measure electrodermal activity (EDA). Typically measured using direct current (DC) excitation, EDA is often affected by signal drift due to electrode–skin polarisation. To address this, a portable device was developed that applies fixed-amplitude, full-wave AC signals and records EDA under controlled conditions. The electrical behaviour of the skin was also simulated using a multilayer model to analyse current propagation at different frequencies. The experimental procedure was conducted with ten healthy participants under controlled conditions. Two stages were carried out: the first compared the similarity of the skin conductance level (SCL) between DC and half-wave alternating current (AC) signals; the second analysed signal stability and skin response at full-wave AC excitation. Compared to DC, full-wave AC excitation demonstrated reduced signal drift, greater temporal stability, and enhanced measurement of the skin’s capacitive response. These findings support the adoption of AC excitation for EDA measurement, especially in ambulatory and real-time biomechanical applications where signal reliability and stability are essential.


  • Open Access

    Muscle Networks Dynamic in Demanding Postural Tasks and Visual Feedback Privation: A Preliminary Study

    by Ana Lía Albarracín, Fernando Daniel Farfán, Leonardo Ariel Cano, Juan D. Romero-Ante, Juan S. Montenegro-Bravo, Eduardo Fernandez-Jover

    Postural stability relies on the effective interaction between sensory feedback integration and muscle modulation. This study investigates the dynamics of muscle networks generated during challenging postures and examines the impact of visual feedback deprivation on balance. The postural conditions included three tasks selected from the Berg Balance Scale: standing feet apart, standing feet together, and tandem stance. Additionally, these postures were performed with both open and closed eyes. Electromyographic (EMG) signals were collected bilaterally from six leg and hip muscles. Intermuscular coherence (IMC) was calculated across the twelve muscles within the beta frequency band to identify the muscle networks activated under different postural conditions. The findings revealed a decrease in the number of connections across the sequence of postures, alongside the strengthening of specific muscle connections unique to each individual. These shared patterns and individualized muscle networks may reflect adaptive strategies employed to maintain stability during challenging postural tasks.


  • Open Access

    Actividad electrodérmica como indicador preventivo de complicaciones por neuropatía periférica

    by Juan David Romero-Ante, Jose Maria Vicente-Samper, Juliana Manrique-Cordoba, Vicente Esteve-Sala, Miguel Angel De la Casa Lillo, Jose Maria Sabater Navarro

    La neuropatía periférica (NP) es una afección causada por el daño a los nervios periféricos, responsables del movimiento de los brazos y piernas. La NP puede afectar los nervios autónomos, alterando la función sudomotora y generando piel seca y agrietada. Este artículo explora el uso de las propiedades eléctricas de la piel para medir la actividad electrodérmica (EDA) y su utilidad en la evaluación del grado de afectación de la NP. Se ofrece una visión general de la NP y las características de la señal de EDA, así como algunos modelos eléctricos utilizados para su medición. Además, se revisan estudios que relacionan la EDA con el nivel de afectación del paciente. Finalmente, se presenta el diseño de un circuito electrónico para medir la EDA, con el objetivo de desarrollar un sistema portátil capaz de monitorizar en tiempo real la conductancia eléctrica de la piel de la planta del pie, facilitando el seguimiento a nivel ambulatorio de los pacientes.


  • Open Access

    Análisis de presión plantar para el diseño de plantillas personalizadas

    by Juan David Romero-Ante, Juan Sebastian Montenegro-Bravo, Daniel Alejandro Rodriguez-Lopez, Jose Maria Vicente-Samper, A. Rodríguez-Martínez, Jose Maria Sabater Navarro

    La enfermedad arterial periférica (EAP) se caracteriza por la obstrucción de las arterias de las piernas y los pies debido a la acumulación de grasa. La neuropatía periférica (NP) afecta a la función de los nervios, incluidos los responsables de regular la sudoración y la humedad de los pies. Estos problemas aumentan significativamente el riesgo de úlceras y heridas en las extremidades. Este artículo presenta una metodología de análisis de la presión plantar con el equipo F-Scan64 para identificar puntos críticos durante las actividades diarias. El objetivo es diseñar plantillas personalizadas que monitoricen estos puntos y reduzcan el riesgo de lesiones en pacientes con estas afecciones. Los resultados se discuten en relación con estudios previos sobre los umbrales de riesgo que deben evitarse en estos casos. Además, se ofrece una perspectiva sobre la distribución sensorial de las plantillas personalizadas.

  • Open Access

    Modelado del efecto del ciclo menstrual de una paciente DM1 usando SimBiology

    by Marina Poveda Perez, Juan David Romero-Ante, Juliana Manrique-Cordoba, Carlos Jara-Bravo, Jose Maria Sabater Navarro

    La diabetes mellitus tipo 1 (DM1) es una enfermedad autoinmune que causa insuficiente producción de insulina debido a la destrucción de las células beta del páncreas. Diversos modelos matemáticos, como el desarrollado por Dalla Man y validado por la FDA, han dado lugar a una serie de estudios que han permitido la adaptación de tratamientos para pacientes con DM1 por Manrique-Córdoba, permitiendo una mejor comprensión y control de la enfermedad. En este estudio, se propone abordar la dinámica de pacientes tipo 1 utilizando la herramienta SimBiology en Matlab. El modelo busca proporcionar una visión más completa de cómo las diferentes etapas del ciclo menstrual pueden influir en sus niveles de glucosa en sangre. Los resultados de simulación permiten analizar la respuesta del modelo ante diversas situaciones y destacan las capacidades gráficas de SimBiology para simular sistemas biológicos. Estos hallazgos mejoran la comprensión de la DM1 y destacan el potencial de estas herramientas para optimizar tratamientos.

  • Open Access

    Validation of a New Ankle Brachial Index Measurement System Using Pulse Wave Velocity

    by Juan David Romero-Ante, Esther Chicharro-Luna, Juliana Manrique-Córdoba, José María Vicente-Samper, Alba Gracia-Sánchez, José María Sabater-Navarro

    Peripheral artery disease (PAD) is a common circulatory disorder characterized by the accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow to the extremities, especially the legs. The ankle brachial index (ABI) is a highly reliable and valid non-invasive test for diagnosing PAD. However, the traditional method has limitations. These include the time required, the need for Doppler equipment, the training of clinical staff, and patient discomfort. PWV refers to the speed at which an arterial pressure wave propagates along the arteries, and this speed is conditioned by arterial elasticity and stiffness. To address these limitations, we have developed a system that uses electrocardiogram (ECG) and photoplethysmography (PPG) signals to calculate pulse wave velocity (PWV). We propose determining the ABI based on this calculation. Validation was performed on 22 diabetic patients, and the results demonstrate the accuracy of the system, maintaining a margin of ±0.1 compared with the traditional method. This confirms the correlation between PWV and ABI and positions this technique as a promising alternative to overcome some of the limitations of the conventional method.