SPSofia Cláudia Peixoto-De-Matos

Sofia Cláudia Peixoto-De-Matos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sofia Cláudia Peixoto-De-Matos has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    A 3‐year Randomized Clinical Trial of MiSight Lenses for Myopia Control

    by Paul Chamberlain, Sofia C. Peixoto‐De‐Matos, Nicola S. Logan, Cheryl Ngo, Deborah Jones, Graeme Young

    SIGNIFICANCE: Results of this randomized, double‐masked clinical trial demonstrate the effectiveness of the MiSight soft contact lens in slowing myopia progression over multiple years. PURPOSE: The purpose of this study was to quantify the effectiveness of MiSight daily disposable soft contact lens in slowing the progression of juvenile‐onset myopia. METHODS: Myopic children (spherical equivalent refraction, −0.75 to −4.00 D; astigmatism, P <. 001). Mean change in axial length was 0.32 mm (52%) less in the test group than in the control group (0.30 ± 0.27 vs. 0.62 ± 0.30 mm, P <. 001). Changes in spherical equivalent refraction and axial length were highly correlated ( r = −0.90, P <. 001). Over the course of the study, there were no cases of serious ocular adverse events reported. Four asymptomatic corneal infiltrative (one test, three control) events were observed at scheduled study visits. CONCLUSIONS: Results of this clinical trial demonstrate the effectiveness of the MiSight daily disposable soft contact lens in slowing change in spherical equivalent refraction and axial length.


  • Light distortion and spherical aberration for the accommodating and nonaccommodating eye

    by Rute Macedo-De-Araújo, Helena Ferreira-Neves, Laura Rico-Del-Viejo, Sofia C. Peixoto-De-Matos, José Manuel González-Méijome

    To evaluate how different amounts of induced spherical aberration (SA) affect the light distortion (LD) phenomena, tests were performed using an experimental device to measure the distortion (haloes, glare, and so on) of a point source. To simulate the effect of SA, eight different phase plates between +0.300 and −0.300  μm of SA for a 5-mm aperture were used in a random and double-masked experimental design. Measurements were performed at a distance of 2 m in a darkened room in 10 eyes of five subjects with a mean age of 26.4±6.1 years and a mean refractive error of −0.50±0.70  D. Data were obtained with natural pupil and after pupil dilatation. The measurements with this experimental system showed a significant increase in all distortion parameters with cycloplegia for the phase plates with the higher positive SA (+0.300 and +0.150  μm). The disturbance index increased from 14.86±6.12% to 57.98±36.20% (p<0.05) with the +0.300  μm plate. The same effect was observed through at a much lower rate when the eye could accommodate. Plates inducing negative SA did not change the LD compared to the control condition without induction of SA or even decreased the effect of distortion. Pupillary dilation and cyclopegia led to a significant increase in the size of the LD when increasing values of SA were induced. Accommodation and pupillary constriction are capable of compensating the degradation of the optical quality induced.


  • Symptoms and Signs in Rigid Gas Permeable Lens Wearers During Adaptation Period

    by Gonzalo Carracedo, Alba Martin-Gil, Sofia C. Peixoto-De-Matos, Pilar Abejón-Gil, Rute Macedo-De-Araújo, Jose M. González-Méijome

    To evaluate neophyte contact lens wearers' fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.12±2.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a significant increase at 10 days (P<0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.


  • Stabilization in early adult-onset myopia with corneal refractive therapy

    by José M. González-Méijome, Gonzalo Carracedo, Daniela Lopes-Ferreira, Miguel A. Faria-Ribeiro, Sofia C. Peixoto-De-Matos, António Queirós


  • Strategies to Regulate Myopia Progression With Contact Lenses

    by José M. González-Méijome, Sofia C. Peixoto-De-Matos, Miguel Faria-Ribeiro, Daniela P. Lopes-Ferreira, Jorge Jorge, Jerry Legerton, Antonio Queiros

    Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. A review commenced by searching the PubMed database. The inclusion criteria stipulated publications of clinical trials evaluating the efficacy of CLs in regulating myopia progression based on the primary endpoint of changes in axial length measurements and published in peer-reviewed journals. Other publications from conference proceedings or patents were exceptionally considered when no peer-review articles were available. The mechanisms that presently support myopia regulation with CLs are based on the change of relative peripheral defocus and changing the foveal image quality signal to potentially interfere with the accommodative system. Ten clinical trials addressing myopia regulation with CLs were reviewed, including corneal refractive therapy (orthokeratology), peripheral gradient lenses, and bifocal (dual-focus) and multifocal lenses. CLs were reported to be well accepted, consistent, and safe methods to address myopia regulation in children. Corneal refractive therapy (orthokeratology) is so far the method with the largest demonstrated efficacy in myopia regulation across different ethnic groups. However, factors such as patient convenience, the degree of initial myopia, and non-CL treatments may also be considered. The combination of different strategies (i.e., central defocus, peripheral defocus, spectral filters, pharmaceutical delivery, and active lens-borne illumination) in a single device will present further testable hypotheses exploring how different mechanisms can reinforce or compete with each other to improve or reduce myopia regulation with CLs.


  • Comments to paper entitled: Predicting scleral GP lens entrapped tear layer oxygen tensions

    by Vicente Compañ, M. Aguilella-Arzo, Alvaro E. Montero, Sergio Mollá, C. Oliveira, S.C. Peixoto-De-Matos, J.M. González-Méijome


  • Open Access

    Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens

    by Nery García-Porta, Laura Rico-Del-Viejo, Helena Ferreira-Neves, Sofia C. Peixoto-De-Matos, Antonio Queirós, José M. González-Méijome

    Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs).Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating.Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P<0.05, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-WhitneyUtest). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P<0.05, Kruskal-Wallis test), being higher for Synergi (Mann-WhitneyUtest). The subjective comfort was similar with the three MPDSs.Conclusion.Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.


  • Oxygen Diffusion and Edema With Modern Scleral Rigid Gas Permeable Contact Lenses

    by Vicente Compañ, Cristina Oliveira, Marcel Aguilella-Arzo, Sergio Mollá, Sofia C. Peixoto-De-Matos, José M. González-Méijome

    Purpose. We defined the theoretical oxygen tension behind modern scleral contact lenses (CLs) made of different rigid gas permeable (RGP) materials, assuming different thickness of the tear layer behind the lens. A second goal was to show clinically the effect of the postlens tear film on corneal swelling. Methods. We simulated the partial pressure of oxygen across the cornea behind scleral CLs made of different lens materials (oxygen permeability Dk, 75–200 barrer) and different thickness (Tav, 100–300 μm). Postlens tear film thicknesses (Tpost-tear) ranging from 150 to 350 μm were considered. Eight healthy subjects were fitted randomly with a scleral lens with a thin and a thick postlens tear layer in two different sessions for a period of 3 hours under open-eye conditions. Results. The CLs with less than 125 barrer of Dk and a thickness over 200 μm depleted the oxygen availability at the lens–cornea interface below 55 mm Hg for a postlens tear film of 150 μm. For a postlens tear film thickness of 350 μm, no combination of material or lens thickness will meet the criteria of 55 mm Hg. Our clinical measures of corneal edema showed that this was significantly higher (P < 0.001, Wilcoxon signed ranks test) with the thicker compared to the thinner Tpost-tear (mean ± SD, 1.66 ± 1.12 vs. 4.27 ± 1.19%). Conclusions. Scleral RGP CLs must be comprised of at least 125 barrer of oxygen permeability and up to 200 μm thick to avoid hypoxic effects even under open eye conditions. Postlens tear film layer should be below 150 μm to avoid clinically significant edema.


  • Multi-site clinical assessment of Complete Revitalens MPDS in 2981 contact lens wearers across Europe and USA

    by J.M. González-Méijome, A.C. da Silva, M. Faria-Ribeiro, D. Lopes-Ferreira, S.C. Peixoto-De-Matos


  • Open Access

    Ocular Dominance and Visual Function Testing

    by D. Lopes-Ferreira, H. Neves, A. Queiros, M. Faria-Ribeiro, S. C. Peixoto-De-Matos, J. M. González-Méijome

    Purpose. To show the distribution of ocular dominance as measured with sensory and eye sighting methods and its potential relationship with high and low contrast LogMAR visual acuity in presbyopic subjects.Method. Forty-four presbyopes (48.5 ± 3.5 years) participated in this study. Ocular dominance was determined by eye sighting (hole-in-card) and sensorial (+1.50 D lens induced blur) methods. According to the dominance detected with each method (RE: right eye or LE: left eye), patients were classified in dominance type 1 (RE/RE), type 2 (RE/LE), type 3 (LE/RE) and type 4 (LE/LE).Results. Baseline refractive error (MSE) was RE:−0.36 ± 1.67 D and LE:−0.35 ± 1.85 D (P=0.930). RE was the dominant eye in 61.4% and 70.5% of times as obtained from sensorial and sighting methods, respectively. Most frequent dominance was of type 1 (52.3%), in this case the RE showed statistically significant better distance low contrast LogMAR VA (0.04 LogMAR units) compared to the LE (P<0.05).Conclusions. The dominance was more frequent in RE in this sample. The eye sighting and sensorial methods to define ocular dominance agreed in more than half of cases. Amount of MSE was not significantly different between dominant and non-dominant eye. But in case of right dominance, the RE presented better distance low contrast VA compared to the LE.