Sofia Cláudia Peixoto-De-Matos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sofia Cláudia Peixoto-De-Matos has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Jose Manuel Gonzalez-Meijome
Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
14 shared publications - António Queirós
Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
6 shared publications - Jorge Jorge
University of Minho
5 shared publications - Daniela Lopes-Ferreira
Universidade do Minho Escola de Ciencias
4 shared publications - Miguel Faria-Ribeiro
Department of Physics, University of Minho, Braga, Portugal
4 shared publications - Alejandro Cerviño
Department of Optics & Optometry & Vision Sciences, University of Valencia, Burjassot, Valencia, Spain
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 1 August 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (8) , 556-567
A 3‐year Randomized Clinical Trial of MiSight Lenses for Myopia Control
SIGNIFICANCE: Results of this randomized, double‐masked clinical trial demonstrate the effectiveness of the MiSight soft contact lens in slowing myopia progression over multiple years. PURPOSE: The purpose of this study was to quantify the effectiveness of MiSight daily disposable soft contact lens in slowing the progression of juvenile‐onset myopia. METHODS: Myopic children (spherical equivalent refraction, −0.75 to −4.00 D; astigmatism, P <. 001). Mean change in axial length was 0.32 mm (52%) less in the test group than in the control group (0.30 ± 0.27 vs. 0.62 ± 0.30 mm, P <. 001). Changes in spherical equivalent refraction and axial length were highly correlated ( r = −0.90, P <. 001). Over the course of the study, there were no cases of serious ocular adverse events reported. Four asymptomatic corneal infiltrative (one test, three control) events were observed at scheduled study visits. CONCLUSIONS: Results of this clinical trial demonstrate the effectiveness of the MiSight daily disposable soft contact lens in slowing change in spherical equivalent refraction and axial length.
- 1 August 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (8) , 556-567
Top Cited PapersOpen AccessA 3‐year Randomized Clinical Trial of MiSight Lenses for Myopia Control
SIGNIFICANCE: Results of this randomized, double‐masked clinical trial demonstrate the effectiveness of the MiSight soft contact lens in slowing myopia progression over multiple years. PURPOSE: The purpose of this study was to quantify the effectiveness of MiSight daily disposable soft contact lens in slowing the progression of juvenile‐onset myopia. METHODS: Myopic children (spherical equivalent refraction, −0.75 to −4.00 D; astigmatism, P <. 001). Mean change in axial length was 0.32 mm (52%) less in the test group than in the control group (0.30 ± 0.27 vs. 0.62 ± 0.30 mm, P <. 001). Changes in spherical equivalent refraction and axial length were highly correlated ( r = −0.90, P <. 001). Over the course of the study, there were no cases of serious ocular adverse events reported. Four asymptomatic corneal infiltrative (one test, three control) events were observed at scheduled study visits. CONCLUSIONS: Results of this clinical trial demonstrate the effectiveness of the MiSight daily disposable soft contact lens in slowing change in spherical equivalent refraction and axial length.
- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 075003
Light distortion and spherical aberration for the accommodating and nonaccommodating eye
To evaluate how different amounts of induced spherical aberration (SA) affect the light distortion (LD) phenomena, tests were performed using an experimental device to measure the distortion (haloes, glare, and so on) of a point source. To simulate the effect of SA, eight different phase plates between and of SA for a 5-mm aperture were used in a random and double-masked experimental design. Measurements were performed at a distance of 2 m in a darkened room in 10 eyes of five subjects with a mean age of years and a mean refractive error of . Data were obtained with natural pupil and after pupil dilatation. The measurements with this experimental system showed a significant increase in all distortion parameters with cycloplegia for the phase plates with the higher positive SA ( and ). The disturbance index increased from to () with the plate. The same effect was observed through at a much lower rate when the eye could accommodate. Plates inducing negative SA did not change the LD compared to the control condition without induction of SA or even decreased the effect of distortion. Pupillary dilation and cyclopegia led to a significant increase in the size of the LD when increasing values of SA were induced. Accommodation and pupillary constriction are capable of compensating the degradation of the optical quality induced.- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 075003
Light distortion and spherical aberration for the accommodating and nonaccommodating eye
To evaluate how different amounts of induced spherical aberration (SA) affect the light distortion (LD) phenomena, tests were performed using an experimental device to measure the distortion (haloes, glare, and so on) of a point source. To simulate the effect of SA, eight different phase plates between and of SA for a 5-mm aperture were used in a random and double-masked experimental design. Measurements were performed at a distance of 2 m in a darkened room in 10 eyes of five subjects with a mean age of years and a mean refractive error of . Data were obtained with natural pupil and after pupil dilatation. The measurements with this experimental system showed a significant increase in all distortion parameters with cycloplegia for the phase plates with the higher positive SA ( and ). The disturbance index increased from to () with the plate. The same effect was observed through at a much lower rate when the eye could accommodate. Plates inducing negative SA did not change the LD compared to the control condition without induction of SA or even decreased the effect of distortion. Pupillary dilation and cyclopegia led to a significant increase in the size of the LD when increasing values of SA were induced. Accommodation and pupillary constriction are capable of compensating the degradation of the optical quality induced.- 1 March 2016
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 42 (2) , 108-114
Symptoms and Signs in Rigid Gas Permeable Lens Wearers During Adaptation Period
To evaluate neophyte contact lens wearers' fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.12±2.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a significant increase at 10 days (P<0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.
- 1 March 2016
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 42 (2) , 108-114
Symptoms and Signs in Rigid Gas Permeable Lens Wearers During Adaptation Period
To evaluate neophyte contact lens wearers' fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.12±2.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a significant increase at 10 days (P<0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.
- 1 February 2016
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 39 (1) , 72-77
Stabilization in early adult-onset myopia with corneal refractive therapy
- 1 February 2016
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 39 (1) , 72-77
Stabilization in early adult-onset myopia with corneal refractive therapy
- 1 January 2016
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 42 (1) , 24-34
Strategies to Regulate Myopia Progression With Contact Lenses
Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. A review commenced by searching the PubMed database. The inclusion criteria stipulated publications of clinical trials evaluating the efficacy of CLs in regulating myopia progression based on the primary endpoint of changes in axial length measurements and published in peer-reviewed journals. Other publications from conference proceedings or patents were exceptionally considered when no peer-review articles were available. The mechanisms that presently support myopia regulation with CLs are based on the change of relative peripheral defocus and changing the foveal image quality signal to potentially interfere with the accommodative system. Ten clinical trials addressing myopia regulation with CLs were reviewed, including corneal refractive therapy (orthokeratology), peripheral gradient lenses, and bifocal (dual-focus) and multifocal lenses. CLs were reported to be well accepted, consistent, and safe methods to address myopia regulation in children. Corneal refractive therapy (orthokeratology) is so far the method with the largest demonstrated efficacy in myopia regulation across different ethnic groups. However, factors such as patient convenience, the degree of initial myopia, and non-CL treatments may also be considered. The combination of different strategies (i.e., central defocus, peripheral defocus, spectral filters, pharmaceutical delivery, and active lens-borne illumination) in a single device will present further testable hypotheses exploring how different mechanisms can reinforce or compete with each other to improve or reduce myopia regulation with CLs.
- 1 January 2016
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 42 (1) , 24-34
Strategies to Regulate Myopia Progression With Contact Lenses
Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. A review commenced by searching the PubMed database. The inclusion criteria stipulated publications of clinical trials evaluating the efficacy of CLs in regulating myopia progression based on the primary endpoint of changes in axial length measurements and published in peer-reviewed journals. Other publications from conference proceedings or patents were exceptionally considered when no peer-review articles were available. The mechanisms that presently support myopia regulation with CLs are based on the change of relative peripheral defocus and changing the foveal image quality signal to potentially interfere with the accommodative system. Ten clinical trials addressing myopia regulation with CLs were reviewed, including corneal refractive therapy (orthokeratology), peripheral gradient lenses, and bifocal (dual-focus) and multifocal lenses. CLs were reported to be well accepted, consistent, and safe methods to address myopia regulation in children. Corneal refractive therapy (orthokeratology) is so far the method with the largest demonstrated efficacy in myopia regulation across different ethnic groups. However, factors such as patient convenience, the degree of initial myopia, and non-CL treatments may also be considered. The combination of different strategies (i.e., central defocus, peripheral defocus, spectral filters, pharmaceutical delivery, and active lens-borne illumination) in a single device will present further testable hypotheses exploring how different mechanisms can reinforce or compete with each other to improve or reduce myopia regulation with CLs.
- 1 October 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38 (5) , 391
Comments to paper entitled: Predicting scleral GP lens entrapped tear layer oxygen tensions
- 1 October 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38 (5) , 391
Comments to paper entitled: Predicting scleral GP lens entrapped tear layer oxygen tensions
- Open Access
- 31 March 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-13
Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens
Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs).Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating.Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitneytest). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (, Kruskal-Wallis test), being higher for Synergi (Mann-Whitneytest). The subjective comfort was similar with the three MPDSs.Conclusion.Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.- 31 March 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-13
Open AccessPerformance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens
Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs).Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating.Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitneytest). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (, Kruskal-Wallis test), being higher for Synergi (Mann-Whitneytest). The subjective comfort was similar with the three MPDSs.Conclusion.Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface. - 1 October 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (10) , 6421-6429
Oxygen Diffusion and Edema With Modern Scleral Rigid Gas Permeable Contact Lenses
Purpose. We defined the theoretical oxygen tension behind modern scleral contact lenses (CLs) made of different rigid gas permeable (RGP) materials, assuming different thickness of the tear layer behind the lens. A second goal was to show clinically the effect of the postlens tear film on corneal swelling. Methods. We simulated the partial pressure of oxygen across the cornea behind scleral CLs made of different lens materials (oxygen permeability Dk, 75–200 barrer) and different thickness (Tav, 100–300 μm). Postlens tear film thicknesses (Tpost-tear) ranging from 150 to 350 μm were considered. Eight healthy subjects were fitted randomly with a scleral lens with a thin and a thick postlens tear layer in two different sessions for a period of 3 hours under open-eye conditions. Results. The CLs with less than 125 barrer of Dk and a thickness over 200 μm depleted the oxygen availability at the lens–cornea interface below 55 mm Hg for a postlens tear film of 150 μm. For a postlens tear film thickness of 350 μm, no combination of material or lens thickness will meet the criteria of 55 mm Hg. Our clinical measures of corneal edema showed that this was significantly higher (P < 0.001, Wilcoxon signed ranks test) with the thicker compared to the thinner Tpost-tear (mean ± SD, 1.66 ± 1.12 vs. 4.27 ± 1.19%). Conclusions. Scleral RGP CLs must be comprised of at least 125 barrer of oxygen permeability and up to 200 μm thick to avoid hypoxic effects even under open eye conditions. Postlens tear film layer should be below 150 μm to avoid clinically significant edema.
- 1 October 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (10) , 6421-6429
Oxygen Diffusion and Edema With Modern Scleral Rigid Gas Permeable Contact Lenses
Purpose. We defined the theoretical oxygen tension behind modern scleral contact lenses (CLs) made of different rigid gas permeable (RGP) materials, assuming different thickness of the tear layer behind the lens. A second goal was to show clinically the effect of the postlens tear film on corneal swelling. Methods. We simulated the partial pressure of oxygen across the cornea behind scleral CLs made of different lens materials (oxygen permeability Dk, 75–200 barrer) and different thickness (Tav, 100–300 μm). Postlens tear film thicknesses (Tpost-tear) ranging from 150 to 350 μm were considered. Eight healthy subjects were fitted randomly with a scleral lens with a thin and a thick postlens tear layer in two different sessions for a period of 3 hours under open-eye conditions. Results. The CLs with less than 125 barrer of Dk and a thickness over 200 μm depleted the oxygen availability at the lens–cornea interface below 55 mm Hg for a postlens tear film of 150 μm. For a postlens tear film thickness of 350 μm, no combination of material or lens thickness will meet the criteria of 55 mm Hg. Our clinical measures of corneal edema showed that this was significantly higher (P < 0.001, Wilcoxon signed ranks test) with the thicker compared to the thinner Tpost-tear (mean ± SD, 1.66 ± 1.12 vs. 4.27 ± 1.19%). Conclusions. Scleral RGP CLs must be comprised of at least 125 barrer of oxygen permeability and up to 200 μm thick to avoid hypoxic effects even under open eye conditions. Postlens tear film layer should be below 150 μm to avoid clinically significant edema.
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36 (6) , 289-293
Multi-site clinical assessment of Complete Revitalens MPDS in 2981 contact lens wearers across Europe and USA
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36 (6) , 289-293
Multi-site clinical assessment of Complete Revitalens MPDS in 2981 contact lens wearers across Europe and USA
- Open Access
- 11 November 2013
- Published by Hindawi Limited in BioMed Research International
- Vol. 2013, 1-7
Ocular Dominance and Visual Function Testing
Purpose. To show the distribution of ocular dominance as measured with sensory and eye sighting methods and its potential relationship with high and low contrast LogMAR visual acuity in presbyopic subjects.Method. Forty-four presbyopes (48.5 ± 3.5 years) participated in this study. Ocular dominance was determined by eye sighting (hole-in-card) and sensorial (+1.50 D lens induced blur) methods. According to the dominance detected with each method (RE: right eye or LE: left eye), patients were classified in dominance type 1 (RE/RE), type 2 (RE/LE), type 3 (LE/RE) and type 4 (LE/LE).Results. Baseline refractive error (MSE) was RE:−0.36 ± 1.67 D and LE:−0.35 ± 1.85 D (). RE was the dominant eye in 61.4% and 70.5% of times as obtained from sensorial and sighting methods, respectively. Most frequent dominance was of type 1 (52.3%), in this case the RE showed statistically significant better distance low contrast LogMAR VA (0.04 LogMAR units) compared to the LE ().Conclusions. The dominance was more frequent in RE in this sample. The eye sighting and sensorial methods to define ocular dominance agreed in more than half of cases. Amount of MSE was not significantly different between dominant and non-dominant eye. But in case of right dominance, the RE presented better distance low contrast VA compared to the LE.- 11 November 2013
- Published by Hindawi Limited in BioMed Research International
- Vol. 2013, 1-7
Open AccessOcular Dominance and Visual Function Testing
Purpose. To show the distribution of ocular dominance as measured with sensory and eye sighting methods and its potential relationship with high and low contrast LogMAR visual acuity in presbyopic subjects.Method. Forty-four presbyopes (48.5 ± 3.5 years) participated in this study. Ocular dominance was determined by eye sighting (hole-in-card) and sensorial (+1.50 D lens induced blur) methods. According to the dominance detected with each method (RE: right eye or LE: left eye), patients were classified in dominance type 1 (RE/RE), type 2 (RE/LE), type 3 (LE/RE) and type 4 (LE/LE).Results. Baseline refractive error (MSE) was RE:−0.36 ± 1.67 D and LE:−0.35 ± 1.85 D (). RE was the dominant eye in 61.4% and 70.5% of times as obtained from sensorial and sighting methods, respectively. Most frequent dominance was of type 1 (52.3%), in this case the RE showed statistically significant better distance low contrast LogMAR VA (0.04 LogMAR units) compared to the LE ().Conclusions. The dominance was more frequent in RE in this sample. The eye sighting and sensorial methods to define ocular dominance agreed in more than half of cases. Amount of MSE was not significantly different between dominant and non-dominant eye. But in case of right dominance, the RE presented better distance low contrast VA compared to the LE.