Alexander Backer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander Backer has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Stefan Drese
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
6 shared publications - Viktor Fairuschin
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
2 shared publications - Conrad R. Wolf
Institute for Sensor and Actuator Technology, Coburg University of Applied Science, 96450 Coburg, Germany
1 shared publication - Felix Brand
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
1 shared publication - Gerhard Fischerauer
Fakultät für Ingenieurwissenschaften , Universität Bayreuth , 95440 Bayreuth , Germany
1 shared publication Gerhard Lindner
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Coburg, Germany
1 shared publication
Latest Publications
- Open Access
- 19 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (16) , 9116
FEM-Based Modeling of Guided Acoustic Waves on Free and Fluid-Loaded Plates
Nowadays, guided acoustic waves (GAW) are used for many sensor and actuator applications. The use of numerical methods can facilitate the development and optimization process enormously. In this work, a universally applicable finite element method (FEM)-based model is introduced to determine the dispersion relations of guided acoustic waves. A 2-dimensional unit cell model with Floquet periodicity is used to calculate the corresponding band structure diagrams. Starting from a free plate the model is expanded to encompass single-sided fluid loading. Followed by a straightforward algorithm for post-processing, the data is presented. Additionally, a parametric optimizer is used to adapt the simulations to experimental data measured by a laser Doppler vibrometer on an aluminum plate. Finally, the accuracy of the FEM model is compared to two reference models, achieving good consistency. In the case of the fluid-loaded model, the behavior of critical interactions between the dispersion curves and model-based artifacts is discussed. This approach can be used to model 2D structures like phononic crystals, which cannot be simulated by common GAW models. Moreover, this method can be used as input for advanced multiphysics simulations, including acoustic streaming applications.
- 19 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (16) , 9116
Open AccessFEM-Based Modeling of Guided Acoustic Waves on Free and Fluid-Loaded Plates
Nowadays, guided acoustic waves (GAW) are used for many sensor and actuator applications. The use of numerical methods can facilitate the development and optimization process enormously. In this work, a universally applicable finite element method (FEM)-based model is introduced to determine the dispersion relations of guided acoustic waves. A 2-dimensional unit cell model with Floquet periodicity is used to calculate the corresponding band structure diagrams. Starting from a free plate the model is expanded to encompass single-sided fluid loading. Followed by a straightforward algorithm for post-processing, the data is presented. Additionally, a parametric optimizer is used to adapt the simulations to experimental data measured by a laser Doppler vibrometer on an aluminum plate. Finally, the accuracy of the FEM model is compared to two reference models, achieving good consistency. In the case of the fluid-loaded model, the behavior of critical interactions between the dispersion curves and model-based artifacts is discussed. This approach can be used to model 2D structures like phononic crystals, which cannot be simulated by common GAW models. Moreover, this method can be used as input for advanced multiphysics simulations, including acoustic streaming applications.
- 8 April 2025
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 92 (6) , 214-222
Phased-Array basiertes Structural Health Monitoring zur Delaminationserkennung bei Mehrschichtsystemen
Zusammenfassung: Geführte Akustische Wellen (GAW) haben sich im Themengebiet des Structural Health Monitoring (SHM) etabliert. Neben ihren Vorteilen bei der Überwachung von Objekten und Detektion von Fehlstellen, gibt es jedoch auch einige Herausforderungen. Zu diesen zählt die dispersive Natur der häufig eingesetzten Lambwellen. Dispersion führt zu Signalverzerrung und reduziert dadurch die räumliche Auflösung und erschwert die Erkennung von schwach reflektierenden Fehlstellen. In diesem Beitrag wird der Einsatz eines Phased-Array-Systems zur Delaminationserkennung bei einem Mehrschichtsystem demonstriert, bei dem dispersive Lambwellen zum Einsatz kommen. Durch das Kompensieren der Dispersionseffekte kann die Sign Coherence Factor (SCF) Erweiterung des Total Focusing Method (TFM) Algorithmus eingesetzt und so auch schwach reflektierende Fehlstellen erkannt werden. Des Weiteren wird auf das Entstehen von Modenüberlagerungen bei Mehrschichtsystemen eingegangen, die bei der Auswahl der Arbeitsfrequenz und Sendesignallänge des Phased-Array-Systems berücksichtigt werden müssen.
- 8 April 2025
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 92 (6) , 214-222
Phased-Array basiertes Structural Health Monitoring zur Delaminationserkennung bei Mehrschichtsystemen
Zusammenfassung: Geführte Akustische Wellen (GAW) haben sich im Themengebiet des Structural Health Monitoring (SHM) etabliert. Neben ihren Vorteilen bei der Überwachung von Objekten und Detektion von Fehlstellen, gibt es jedoch auch einige Herausforderungen. Zu diesen zählt die dispersive Natur der häufig eingesetzten Lambwellen. Dispersion führt zu Signalverzerrung und reduziert dadurch die räumliche Auflösung und erschwert die Erkennung von schwach reflektierenden Fehlstellen. In diesem Beitrag wird der Einsatz eines Phased-Array-Systems zur Delaminationserkennung bei einem Mehrschichtsystem demonstriert, bei dem dispersive Lambwellen zum Einsatz kommen. Durch das Kompensieren der Dispersionseffekte kann die Sign Coherence Factor (SCF) Erweiterung des Total Focusing Method (TFM) Algorithmus eingesetzt und so auch schwach reflektierende Fehlstellen erkannt werden. Des Weiteren wird auf das Entstehen von Modenüberlagerungen bei Mehrschichtsystemen eingegangen, die bei der Auswahl der Arbeitsfrequenz und Sendesignallänge des Phased-Array-Systems berücksichtigt werden müssen.
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 306-312
D1.3 - Bestimmung der Materialeigenschaften von Rohren und innen liegenden Schichten mittels geführten akustischen Wellen
Zusammenfassung Für die nichtinvasive Durchflussmessung werden meist Ultraschallsensoren verwendet, die reversibel an das zu untersuchende Rohrsystem angebaut werden. Die Messgenauigkeit dieser Sensoren wird durch mögliche Ablagerungen im Rohrinneren beeinflusst. In dem hier vorgestellten Forschungsvorhaben, soll es mit Hilfe eines ultraschallbasierten Messverfahren möglich sein, sowohl die Materialeigenschaften und Wandstärke des Rohres direkt zu ermitteln als auch eventuell vorhandene Schichten im Rohrinneren zu detektieren und
- 1 January 2024
- Published by AMA Service GmbH
- p. 306-312
Open AccessD1.3 - Bestimmung der Materialeigenschaften von Rohren und innen liegenden Schichten mittels geführten akustischen Wellen
Zusammenfassung Für die nichtinvasive Durchflussmessung werden meist Ultraschallsensoren verwendet, die reversibel an das zu untersuchende Rohrsystem angebaut werden. Die Messgenauigkeit dieser Sensoren wird durch mögliche Ablagerungen im Rohrinneren beeinflusst. In dem hier vorgestellten Forschungsvorhaben, soll es mit Hilfe eines ultraschallbasierten Messverfahren möglich sein, sowohl die Materialeigenschaften und Wandstärke des Rohres direkt zu ermitteln als auch eventuell vorhandene Schichten im Rohrinneren zu detektieren und
- Open Access
Guided Acoustic Waves in Polymer Rods with Varying Immersion Depth in Liquid
Monitoring tanks and vessels play an important part in public infrastructure and several industrial processes. The goal of this work is to propose a new kind of guided acoustic wave sensor for measuring immersion depth. Common sensor types such as pressure sensors and airborne ultrasonic sensors are often limited to non-corrosive media, and can fail to distinguish between the media they reflect on or are submerged in. Motivated by this limitation, we developed a guided acoustic wave sensor made from polyethylene using piezoceramics. In contrast to existing sensors, low-frequency Hanning-windowed sine bursts were used to excite the L(0,1) mode within a solid polyethylene rod. The acoustic velocity within these rods changes with the immersion depth in the surrounding fluid. Thus, it is possible to detect changes in the surrounding media by measuring the time shifts of zero crossings through the rod after being reflected on the opposite end. The change in time of zero crossings is monotonically related to the immersion depth. This relative measurement method can be used in different kinds of liquids, including strong acids or bases.
Open AccessGuided Acoustic Waves in Polymer Rods with Varying Immersion Depth in Liquid
Monitoring tanks and vessels play an important part in public infrastructure and several industrial processes. The goal of this work is to propose a new kind of guided acoustic wave sensor for measuring immersion depth. Common sensor types such as pressure sensors and airborne ultrasonic sensors are often limited to non-corrosive media, and can fail to distinguish between the media they reflect on or are submerged in. Motivated by this limitation, we developed a guided acoustic wave sensor made from polyethylene using piezoceramics. In contrast to existing sensors, low-frequency Hanning-windowed sine bursts were used to excite the L(0,1) mode within a solid polyethylene rod. The acoustic velocity within these rods changes with the immersion depth in the surrounding fluid. Thus, it is possible to detect changes in the surrounding media by measuring the time shifts of zero crossings through the rod after being reflected on the opposite end. The change in time of zero crossings is monotonically related to the immersion depth. This relative measurement method can be used in different kinds of liquids, including strong acids or bases.
- Open Access
On Dispersion Compensation for GAW-Based Structural Health Monitoring
Guided acoustic waves (GAW) have proven to be a useful tool for structural health monitoring (SHM). However, the dispersive nature of commonly used Lamb waves compromises the spatial resolution making it difficult to detect small or weakly reflective defects. Here we demonstrate an approach that can compensate for the dispersive effects, allowing advanced algorithms to be used with significantly higher signal-to-noise ratio and spatial resolution. In this paper, the sign coherence factor (SCF) extension of the total focusing method (TFM) algorithm is used. The effectiveness is examined by numerical simulation and experimentally demonstrated by detecting weakly reflective layers with a highly dispersive A0 mode on an aluminum plate, which are not detectable without compensating for the dispersion effects.
Open AccessOn Dispersion Compensation for GAW-Based Structural Health Monitoring
Guided acoustic waves (GAW) have proven to be a useful tool for structural health monitoring (SHM). However, the dispersive nature of commonly used Lamb waves compromises the spatial resolution making it difficult to detect small or weakly reflective defects. Here we demonstrate an approach that can compensate for the dispersive effects, allowing advanced algorithms to be used with significantly higher signal-to-noise ratio and spatial resolution. In this paper, the sign coherence factor (SCF) extension of the total focusing method (TFM) algorithm is used. The effectiveness is examined by numerical simulation and experimentally demonstrated by detecting weakly reflective layers with a highly dispersive A0 mode on an aluminum plate, which are not detectable without compensating for the dispersion effects.
- Open Access
Elastic Properties Measurement Using Guided Acoustic Waves
Nondestructive evaluation of elastic properties plays a critical role in condition monitoring of thin structures such as sheets, plates or tubes. Recent research has shown that elastic properties of such structures can be determined with remarkable accuracy by utilizing the dispersive nature of guided acoustic waves propagating in them. However, existing techniques largely require complicated and expensive equipment or involve accurate measurement of an additional quantity, rendering them impractical for industrial use. In this work, we present a new approach that requires only a pair of piezoelectric transducers used to measure the group velocities ratio of fundamental guided wave modes. A numerical model based on the spectral collocation method is used to fit the measured data by solving a bound-constrained nonlinear least squares optimization problem. We verify our approach on both simulated and experimental data and achieve accuracies similar to those reported by other authors. The high accuracy and simple measurement setup of our approach makes it eminently suitable for use in industrial environments.
Open AccessElastic Properties Measurement Using Guided Acoustic Waves
Nondestructive evaluation of elastic properties plays a critical role in condition monitoring of thin structures such as sheets, plates or tubes. Recent research has shown that elastic properties of such structures can be determined with remarkable accuracy by utilizing the dispersive nature of guided acoustic waves propagating in them. However, existing techniques largely require complicated and expensive equipment or involve accurate measurement of an additional quantity, rendering them impractical for industrial use. In this work, we present a new approach that requires only a pair of piezoelectric transducers used to measure the group velocities ratio of fundamental guided wave modes. A numerical model based on the spectral collocation method is used to fit the measured data by solving a bound-constrained nonlinear least squares optimization problem. We verify our approach on both simulated and experimental data and achieve accuracies similar to those reported by other authors. The high accuracy and simple measurement setup of our approach makes it eminently suitable for use in industrial environments.
- Open Access
- 1 May 2021
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 18 (3) , 534-547
Actuation of Liquid Flow by Guided Acoustic Waves on Punched Steel Tapes with Protruding Loops
In a biomimetic approach the feasibility of liquid flow actuation by vibrating protruding structures excited via guided acoustic waves is investigated. Inspired by periodically beating cilia the loop part of a punched metallic hook-and-loop tape with tilted protruding loops was used as a waveguide for plate waves in water. Such waves were excited in the frequency range of 110 Hz to 220 Hz by directly coupling the tape to a loudspeaker membrane. A flow generated in the tilt direction of the loops with velocities up to 60 mm·s−1 was visualized by ink droplets deposited on the tape. The phenomenon persisted, when the protruding length of the loops was reduced by decreasing the protrusion angle. However, after closing the punch holes near the loops with sticking tape streaming could not be observed any longer. The same happened with open punch holes when the ink was replaced by glycerol. Low-frequency acoustic streaming around vibrating sharp edges is proposed as an explanation for the observed phenomena. Applications are expected with respect to the modification of flow profiles and the enhancement of transport processes along and across liquid-solid boundaries.
- 1 May 2021
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 18 (3) , 534-547
Open AccessActuation of Liquid Flow by Guided Acoustic Waves on Punched Steel Tapes with Protruding Loops
In a biomimetic approach the feasibility of liquid flow actuation by vibrating protruding structures excited via guided acoustic waves is investigated. Inspired by periodically beating cilia the loop part of a punched metallic hook-and-loop tape with tilted protruding loops was used as a waveguide for plate waves in water. Such waves were excited in the frequency range of 110 Hz to 220 Hz by directly coupling the tape to a loudspeaker membrane. A flow generated in the tilt direction of the loops with velocities up to 60 mm·s−1 was visualized by ink droplets deposited on the tape. The phenomenon persisted, when the protruding length of the loops was reduced by decreasing the protrusion angle. However, after closing the punch holes near the loops with sticking tape streaming could not be observed any longer. The same happened with open punch holes when the ink was replaced by glycerol. Low-frequency acoustic streaming around vibrating sharp edges is proposed as an explanation for the observed phenomena. Applications are expected with respect to the modification of flow profiles and the enhancement of transport processes along and across liquid-solid boundaries.