Ervin Kocjancic
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ervin Kocjancic has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Frea
Turin, Italy
3 shared publications - Paolo Gontero
Department of Urology, Città della Salute e della Scienza University of Torino School of Medicine Torino Italy
3 shared publications Simone Crivellaro
Clinica Urologica, Ospedale Maggiore della Carita, Novara, Italy
2 shared publicationsA. Manassero
1 shared publicationA. Singla
1 shared publicationDaniele Bonvini
Clinica Urologica, Ospedale Maggiore della Carita, Novara, Italy
1 shared publication
Latest Publications
- 1 May 2008
- Published by S. Karger AG in Urologia Internationalis
- Vol. 80 (3) , 275-278
Transobturator Tape in the Management of Female Stress Incontinence: Clinical Outcomes at Medium Term Follow-Up
Objective: To assess the efficacy of transobturator tape (TOT) in the management of stress urinary incontinence at a medium term follow-up. Methods: TOT is a polypropylene tape positioned through the obturator foramen. 70 patients with type II urinary stress incontinence were treated with TOT between June 2003 and May 2006. Patients were prospectively studied by physical examination, quality of life questionnaire (I-QOL), visual analog scale, global impression (dry, improved, same, worse), preoperative urodynamic study, and pre- and postoperative flowmetry. Statistical analysis (t test) of the difference in I-QOL scores and flowmetry was made by StatSoft V. 5.1. Results: The average follow-up was 32 (range 12–48) months. The I-QOL score increased statistically significantly by 40 points. The average percent improvement was 80%. 90% (63/70) of the patients were dry and 5% (4/70) were improved. The pre- and postoperative uroflowmetry studies were not statistically different. Vaginal erosion occurred in 4 patients. Conclusion: TOT is a safe procedure with a good efficacy at 32-month follow-up.
- 1 May 2008
- Published by S. Karger AG in Urologia Internationalis
- Vol. 80 (3) , 275-278
Transobturator Tape in the Management of Female Stress Incontinence: Clinical Outcomes at Medium Term Follow-Up
Objective: To assess the efficacy of transobturator tape (TOT) in the management of stress urinary incontinence at a medium term follow-up. Methods: TOT is a polypropylene tape positioned through the obturator foramen. 70 patients with type II urinary stress incontinence were treated with TOT between June 2003 and May 2006. Patients were prospectively studied by physical examination, quality of life questionnaire (I-QOL), visual analog scale, global impression (dry, improved, same, worse), preoperative urodynamic study, and pre- and postoperative flowmetry. Statistical analysis (t test) of the difference in I-QOL scores and flowmetry was made by StatSoft V. 5.1. Results: The average follow-up was 32 (range 12–48) months. The I-QOL score increased statistically significantly by 40 points. The average percent improvement was 80%. 90% (63/70) of the patients were dry and 5% (4/70) were improved. The pre- and postoperative uroflowmetry studies were not statistically different. Vaginal erosion occurred in 4 patients. Conclusion: TOT is a safe procedure with a good efficacy at 32-month follow-up.
- 1 January 2007
- Published by Taylor & Francis in Scandinavian Journal of Urology and Nephrology
- Vol. 41 (4) , 324-328
Adjustable Continence Therapy for the treatment of male stress urinary incontinence: A single-centre study
Objective. To evaluate the Adjustable Continence Therapy (ProACT™) device, a new device for the treatment of male stress urinary incontinence resulting from compromised sphincteric function. Material and methods. A total of 64 males with post-prostatectomy incontinence underwent ProACT implantation. Efficacy was assessed by means of a daily pad count, a direct visual stress test, administration of the Incontinence Quality of Life (IQOL) and patient global impression (PGI) questionnaires and use of a visual analogue scale (VAS) to assess improvement in incontinence. These assessments were performed at baseline, 1, 3, 6 and 12 months after the procedure and annually thereafter. Results. The pad count declined from a median of 5.2 at baseline to 2 at 6 months and to 1.54 at 12 months. The median baseline IQOL score was 31.7, and this improved to 62.5 at 6 months and to 71.1 at 12 months. In terms of postoperative daily pad usage, 43 patients (67%) were considered to be dry, 10 (15%) improved and 11 (17%) unchanged. In terms of the post operative PGI score, 42 patients (66%) considered themselves to have improved greatly, 10 (16%) to have improved quite a lot, 6 (9%) to have improved slightly and 6 (9%) to be unchanged. The average improvement based on the VAS was 80%. The average number of postoperative adjustments was three (range zero to nine). Complications included infection (2/64; 3%), erosion of balloons (5/64; 7.6%), migration (2/64; 3%) and balloon deflation (2/64; 3%). Device removal was required in 9/64 patients (14%) but was easily achieved using local anaesthesia, and this thus permitted further therapeutic intervention. New balloons were implanted following endoscopic confirmation of urethral healing. Conclusion. The ProACT device represents an efficacious treatment modality, which has an acceptable complication rate for a difficult group of patients.
- 1 January 2007
- Published by Taylor & Francis in Scandinavian Journal of Urology and Nephrology
- Vol. 41 (4) , 324-328
Adjustable Continence Therapy for the treatment of male stress urinary incontinence: A single-centre study
Objective. To evaluate the Adjustable Continence Therapy (ProACT™) device, a new device for the treatment of male stress urinary incontinence resulting from compromised sphincteric function. Material and methods. A total of 64 males with post-prostatectomy incontinence underwent ProACT implantation. Efficacy was assessed by means of a daily pad count, a direct visual stress test, administration of the Incontinence Quality of Life (IQOL) and patient global impression (PGI) questionnaires and use of a visual analogue scale (VAS) to assess improvement in incontinence. These assessments were performed at baseline, 1, 3, 6 and 12 months after the procedure and annually thereafter. Results. The pad count declined from a median of 5.2 at baseline to 2 at 6 months and to 1.54 at 12 months. The median baseline IQOL score was 31.7, and this improved to 62.5 at 6 months and to 71.1 at 12 months. In terms of postoperative daily pad usage, 43 patients (67%) were considered to be dry, 10 (15%) improved and 11 (17%) unchanged. In terms of the post operative PGI score, 42 patients (66%) considered themselves to have improved greatly, 10 (16%) to have improved quite a lot, 6 (9%) to have improved slightly and 6 (9%) to be unchanged. The average improvement based on the VAS was 80%. The average number of postoperative adjustments was three (range zero to nine). Complications included infection (2/64; 3%), erosion of balloons (5/64; 7.6%), migration (2/64; 3%) and balloon deflation (2/64; 3%). Device removal was required in 9/64 patients (14%) but was easily achieved using local anaesthesia, and this thus permitted further therapeutic intervention. New balloons were implanted following endoscopic confirmation of urethral healing. Conclusion. The ProACT device represents an efficacious treatment modality, which has an acceptable complication rate for a difficult group of patients.
- 1 September 2005
- Published by S. Karger AG in Urologia Internationalis
- Vol. 75 (2) , 187-188
Sacral Neuromodulation for Urinary Retention in a Kidney-Transplant Patient
Bladder outlet obstruction can negatively affect renal function in the kidney transplant population. Functional obstruction represents a clinical challenge as conventional treatments are either ineffective or not recommended. Sacral neuromodulation was successfully used in functional voiding dysfunction in a kidney transplant patient. This is the first case to be reported in the literature.
- 1 September 2005
- Published by S. Karger AG in Urologia Internationalis
- Vol. 75 (2) , 187-188
Sacral Neuromodulation for Urinary Retention in a Kidney-Transplant Patient
Bladder outlet obstruction can negatively affect renal function in the kidney transplant population. Functional obstruction represents a clinical challenge as conventional treatments are either ineffective or not recommended. Sacral neuromodulation was successfully used in functional voiding dysfunction in a kidney transplant patient. This is the first case to be reported in the literature.