Federica Curti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Federica Curti has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Marco Giannetto
Department of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
2 shared publications Maria Careri
2 shared publications- Roberto Corradini
Department of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
2 shared publications Andrea Rozzi
Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
1 shared publication- Andrea Rozzi
Department of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parma, Italy and INSTM Parma Research Unit, Italy
1 shared publication - Cesar Rodriguez-Emmenegger
DWI – Leibniz Institute for Interactive Materials Forckenbeckstraße 50 52074 Aachen Germany
1 shared publication
Latest Publications
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 320
Surface plasmon resonance-based aptasensor for direct monitoring of thrombin in a minimally processed human blood
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 320
Surface plasmon resonance-based aptasensor for direct monitoring of thrombin in a minimally processed human blood
- 1 March 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 129, 7-14
Novel amperometric genosensor based on peptide nucleic acid (PNA) probes immobilized on carbon nanotubes-screen printed electrodes for the determination of trace levels of non-amplified DNA in genetically modified (GM) soy
- 1 March 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 129, 7-14
Novel amperometric genosensor based on peptide nucleic acid (PNA) probes immobilized on carbon nanotubes-screen printed electrodes for the determination of trace levels of non-amplified DNA in genetically modified (GM) soy
- Open Access
Single-Walled Carbon Nanotubes as Enhancing Substrates for PNA-Based Amperometric Genosensors
A new amperometric sandwich-format genosensor has been implemented on single-walled carbon nanotubes screen printed electrodes (SWCNT-SPEs) and compared in terms of performance with analogous genoassays developed using the same methodology on non-nanostructured glassy carbon platforms (GC-SPE). The working principle of the genosensors is based on the covalent immobilization of Peptide Nucleic Acid (PNA) capture probes (CP) on the electrode surface, carried out through the carboxylic functions present on SWCNT-SPEs (carboxylated SWCNT) or electrochemically induced on GC-SPEs. The sequence of the CP was complementary to a 20-mer portion of the target DNA; a second biotin-tagged PNA signalling probe (SP), with sequence complementary to a different contiguous portion of the target DNA, was used to obtain a sandwich hybrid with an Alkaline Phosphatase-streptavidin conjugate (ALP-Strp). Comparison of the responses obtained from the SWCNT-SPEs with those produced from the non-nanostructured substrates evidenced the remarkable enhancement effect given by the nanostructured electrode platforms, achieved both in terms of loading capability of PNA probes and amplification of the electron transfer phenomena exploited for the signal transduction, giving rise to more than four-fold higher sensitivity when using SWCNT-SPEs. The nanostructured substrate allowed to reach limit of detection (LOD) of 71 pM and limit of quantitation (LOQ) of 256 pM, while the corresponding values obtained with GC-SPEs were 430 pM and 1.43 nM, respectively.
Open AccessSingle-Walled Carbon Nanotubes as Enhancing Substrates for PNA-Based Amperometric Genosensors
A new amperometric sandwich-format genosensor has been implemented on single-walled carbon nanotubes screen printed electrodes (SWCNT-SPEs) and compared in terms of performance with analogous genoassays developed using the same methodology on non-nanostructured glassy carbon platforms (GC-SPE). The working principle of the genosensors is based on the covalent immobilization of Peptide Nucleic Acid (PNA) capture probes (CP) on the electrode surface, carried out through the carboxylic functions present on SWCNT-SPEs (carboxylated SWCNT) or electrochemically induced on GC-SPEs. The sequence of the CP was complementary to a 20-mer portion of the target DNA; a second biotin-tagged PNA signalling probe (SP), with sequence complementary to a different contiguous portion of the target DNA, was used to obtain a sandwich hybrid with an Alkaline Phosphatase-streptavidin conjugate (ALP-Strp). Comparison of the responses obtained from the SWCNT-SPEs with those produced from the non-nanostructured substrates evidenced the remarkable enhancement effect given by the nanostructured electrode platforms, achieved both in terms of loading capability of PNA probes and amplification of the electron transfer phenomena exploited for the signal transduction, giving rise to more than four-fold higher sensitivity when using SWCNT-SPEs. The nanostructured substrate allowed to reach limit of detection (LOD) of 71 pM and limit of quantitation (LOQ) of 256 pM, while the corresponding values obtained with GC-SPEs were 430 pM and 1.43 nM, respectively.