John Leonard Pagliaro
Research Subjects
John Leonard Pagliaro has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Gregory T. Linteris
Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
3 shared publications- Gregory Thomas Linteris
National Institute of Standards and Technology, Gaithersburg, USA
3 shared publications - Scott G. Davis
Dartmouth College, Thayer School of Engineering, 15 Thayer Drive, Hanover, NH, USA 03755
2 shared publications D. Michael Johnson
DNV GL, Spadeadam Research and Testing Bramton Cumbria UK
1 shared publicationDan Allason
DNV GL, Spadeadam Research and Testing Bramton Cumbria UK
1 shared publication- Donald R. BurgessJr.
National Institute of Standards and Technology
1 shared publication
Latest Publications
- 4 March 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (5) , 599-609
Effects of stretch and radiation on the laminar burning velocity of R-32/air flames
Experiments are performed for outwardly propagating spherical flames of R-32/air mixtures at constant pressure. A high-speed video camera captures shadowgraph images from which the flame radius as a function of time is extracted. Direct numerical simulations with an optically thin radiation model and detailed kinetics are performed to predict the flame radius and study the effects of stretch and radiation on the inferred laminar burning velocity. The simulations accurately predict the observed flame radius as a function of time. Analyses of the simulation results show that both stretch and radiation effects are important, occur concurrently, and make extraction of the unstretched adiabatic laminar burning velocity from the experimental data difficult.
- 4 March 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (5) , 599-609
Effects of stretch and radiation on the laminar burning velocity of R-32/air flames
Experiments are performed for outwardly propagating spherical flames of R-32/air mixtures at constant pressure. A high-speed video camera captures shadowgraph images from which the flame radius as a function of time is extracted. Direct numerical simulations with an optically thin radiation model and detailed kinetics are performed to predict the flame radius and study the effects of stretch and radiation on the inferred laminar burning velocity. The simulations accurately predict the observed flame radius as a function of time. Analyses of the simulation results show that both stretch and radiation effects are important, occur concurrently, and make extraction of the unstretched adiabatic laminar burning velocity from the experimental data difficult.
- 27 January 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (5) , 588-598
Comparison of simple and complex methods for determining refrigerant/air laminar burning velocities from the pressure rise in constant-volume experiments
Laminar burning velocity is currently one of the metrics for differentiating refrigerant flammability risk per ANSI/ASHRAE Standard 34-2019, Designation and Safety Classification of Refrigerants. Several methods exist for determining laminar burning velocity, and the HVAC&R industry is currently evaluating whether the constant-volume method (CVM) is appropriate for measuring the burning velocity of refrigerants. This study focuses specifically on the different data reduction techniques that can be applied to yield the laminar burning velocity from the pressure rise in CVM experiments. More specifically, simple analytical expressions and more complex numerical models are applied to estimate the mass fraction of burned gas from the pressure rise x(P), which is a requisite for determining burning velocity from the measure pressure. When following the experimental and post-processing recommendations outlined in this paper, one of the simpler methods of estimating x(P) yields R32/air burning velocities that are within 5% of those deduced using the more complex methods of estimating x(P). The method presented can be applied to experimental pressure rise data obtained in both normal gravity and microgravity.
- 27 January 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (5) , 588-598
Comparison of simple and complex methods for determining refrigerant/air laminar burning velocities from the pressure rise in constant-volume experiments
Laminar burning velocity is currently one of the metrics for differentiating refrigerant flammability risk per ANSI/ASHRAE Standard 34-2019, Designation and Safety Classification of Refrigerants. Several methods exist for determining laminar burning velocity, and the HVAC&R industry is currently evaluating whether the constant-volume method (CVM) is appropriate for measuring the burning velocity of refrigerants. This study focuses specifically on the different data reduction techniques that can be applied to yield the laminar burning velocity from the pressure rise in CVM experiments. More specifically, simple analytical expressions and more complex numerical models are applied to estimate the mass fraction of burned gas from the pressure rise x(P), which is a requisite for determining burning velocity from the measure pressure. When following the experimental and post-processing recommendations outlined in this paper, one of the simpler methods of estimating x(P) yields R32/air burning velocities that are within 5% of those deduced using the more complex methods of estimating x(P). The method presented can be applied to experimental pressure rise data obtained in both normal gravity and microgravity.
- 7 January 2019
- Published by Wiley in Process Safety Progress
- Vol. 38 (4)
Importance of properly designing dust explosion protection systems: Case study – 2014 plywood manufacturing facility fire and explosion
When designing handling and conveying equipment for combustible dusts, it is crucial to properly implement protective measures (e.g., deflagration venting, suppression, and isolation) capable of mitigating the potential consequences in the event the dust is ignited. Generally speaking, dust processing, storage, and collection equipment, such as cyclones, mills, baghouses, dryers, and silos are typically connected via pipes, pneumatic conveyors, and dust extraction or aspiration lines. If a fire or dust explosion occurs in one vessel, or the interconnecting piping, the flame front or pressure can quickly propagate through these conduits to other parts of the plant and potentially escalate to even worse consequences than the original event. Improper design of isolation devices can be costly, as illustrated by this case study on the fire and explosion in a baghouse that occurred on April 26, 2014 at a plywood manufacturing facility in Texas. More specifically, numerous deficiencies in the system design were identified, which included (1) required air stream flow rates; (2) proper isolation designs; (3) exclusion zones in the anticipated path of a vented deflagration; and (4) impeding deflagration vents. The root cause analysis identified that had a dust hazard analysis been properly performed, these deficiencies would have been identified and the explosion in the baghouse could have been avoided. © 2019 American Institute of Chemical Engineers Process Saf Prog: e12036 2019
- 7 January 2019
- Published by Wiley in Process Safety Progress
- Vol. 38 (4)
Importance of properly designing dust explosion protection systems: Case study – 2014 plywood manufacturing facility fire and explosion
When designing handling and conveying equipment for combustible dusts, it is crucial to properly implement protective measures (e.g., deflagration venting, suppression, and isolation) capable of mitigating the potential consequences in the event the dust is ignited. Generally speaking, dust processing, storage, and collection equipment, such as cyclones, mills, baghouses, dryers, and silos are typically connected via pipes, pneumatic conveyors, and dust extraction or aspiration lines. If a fire or dust explosion occurs in one vessel, or the interconnecting piping, the flame front or pressure can quickly propagate through these conduits to other parts of the plant and potentially escalate to even worse consequences than the original event. Improper design of isolation devices can be costly, as illustrated by this case study on the fire and explosion in a baghouse that occurred on April 26, 2014 at a plywood manufacturing facility in Texas. More specifically, numerous deficiencies in the system design were identified, which included (1) required air stream flow rates; (2) proper isolation designs; (3) exclusion zones in the anticipated path of a vented deflagration; and (4) impeding deflagration vents. The root cause analysis identified that had a dust hazard analysis been properly performed, these deficiencies would have been identified and the explosion in the baghouse could have been avoided. © 2019 American Institute of Chemical Engineers Process Saf Prog: e12036 2019
- 1 January 2019
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 37 (3) , 4231-4238
Effects of stretch and thermal radiation on difluoromethane/air burning velocity measurements in constant volume spherically expanding flames
- 1 January 2019
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 37 (3) , 4231-4238
Effects of stretch and thermal radiation on difluoromethane/air burning velocity measurements in constant volume spherically expanding flames
- 22 October 2018
- Published by Wiley in Process Safety Progress
- Vol. 38 (2)
Do not believe the hype: Using case studies and experimental evidence to show why the HSE is wrong about excluding deflagration‐to‐detonation transitions
A recent report by the UK's Health and Safety Executive postulated that severe explosions can propagate at subsonic speeds but generate overpressures of several bar in open areas and this “new” type of explosion is episodic in nature. The UK Health and Safety Executive (HSE) paper based their findings on a specific interpretation of historical data and “empirical evidence” from previous incidents and selected experimental data. They indicate that their results should guide plant design and risk assessment. The report fails to take account of key evidence from recent large‐scale experimental studies and incident investigations in proposing a hypothetical explosion mechanism over those that are known to occur and are well understood. This has the potential to misdirect efforts to manage such events.The first part of the article will review a number of incidents and demonstrate that each of these incidents can indeed be explained by fast deflagrations or transition to detonations, in complete contradiction to the HSE findings. The results found at the incident sites will be directly compared against results from recent DDT work and damage. The second part of the paper will present a novel technique for determining the DDT transition velocity from high‐speed video footage of experiments performed at large scales. © 2018 American Institute of Chemical Engineers Process Saf Prog 38: e11998, 2019
- 22 October 2018
- Published by Wiley in Process Safety Progress
- Vol. 38 (2)
Do not believe the hype: Using case studies and experimental evidence to show why the HSE is wrong about excluding deflagration‐to‐detonation transitions
A recent report by the UK's Health and Safety Executive postulated that severe explosions can propagate at subsonic speeds but generate overpressures of several bar in open areas and this “new” type of explosion is episodic in nature. The UK Health and Safety Executive (HSE) paper based their findings on a specific interpretation of historical data and “empirical evidence” from previous incidents and selected experimental data. They indicate that their results should guide plant design and risk assessment. The report fails to take account of key evidence from recent large‐scale experimental studies and incident investigations in proposing a hypothetical explosion mechanism over those that are known to occur and are well understood. This has the potential to misdirect efforts to manage such events.The first part of the article will review a number of incidents and demonstrate that each of these incidents can indeed be explained by fast deflagrations or transition to detonations, in complete contradiction to the HSE findings. The results found at the incident sites will be directly compared against results from recent DDT work and damage. The second part of the paper will present a novel technique for determining the DDT transition velocity from high‐speed video footage of experiments performed at large scales. © 2018 American Institute of Chemical Engineers Process Saf Prog 38: e11998, 2019
- 1 September 2017
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 49, 662-674
Flammability and explosion characteristics of mildly flammable refrigerants
- 1 September 2017
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 49, 662-674
Flammability and explosion characteristics of mildly flammable refrigerants
- 1 January 2017
- Published by Elsevier in Fire Safety Journal
- Vol. 87, 10-17
Hydrocarbon flame inhibition by C6F12O (Novec 1230): Unstretched burning velocity measurements and predictions
- 1 January 2017
- Published by Elsevier in Fire Safety Journal
- Vol. 87, 10-17
Hydrocarbon flame inhibition by C6F12O (Novec 1230): Unstretched burning velocity measurements and predictions
- 1 July 2016
- Published by Elsevier in Combustion and Flame
- Vol. 169, 272-286
Premixed flame inhibition by CF3Br and C3H2F3Br (2-BTP)
- 1 July 2016
- Published by Elsevier in Combustion and Flame
- Vol. 169, 272-286
Premixed flame inhibition by CF3Br and C3H2F3Br (2-BTP)
- 1 May 2016
- Published by Elsevier in Combustion and Flame
- Vol. 167, 452-462
Understanding overpressure in the FAA aerosol can test by C3H2F3Br (2-BTP)
- 1 May 2016
- Published by Elsevier in Combustion and Flame
- Vol. 167, 452-462
Understanding overpressure in the FAA aerosol can test by C3H2F3Br (2-BTP)