Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jae-Ho Cho has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spatial Assessment of External Heat Flux in Cone Calorimeter Measurements Using Area-Weighted Averaging

    by Jae-Ho Cho, Cheol-Hong Hwang

    External heat flux is a primary thermal input parameter in cone calorimeter tests, with the nominal value conventionally established at the center of the specimen surface. However, the radiant heat flux generated by the cone heater specified in ISO 5660-1 is known to be spatially non-uniform. This study quantified the spatial distribution of external heat flux at nominal levels of 20, 35, and 50 kW/m2 and applied area-weighted spatial averaging to quantify the relationship between the nominal heat flux and the spatially averaged external heat flux over the specimen. The measured heat flux decreased radially toward the specimen boundaries, with local relative deviations reaching approximately −30% near the corners of a standard 0.100 × 0.100 m specimen. Despite this local non-uniformity, the normalized spatial distributions were similar across all three heat flux levels. For the entire specimen, the area-weighted relative deviations were −3.54%, −3.28%, and −3.41% at 20, 35, and 50 kW/m2, respectively, with comparable deviations in total external radiant power. These findings demonstrate that the magnitude of local heat-flux deviation should be distinguished from the specimen-wide spatially averaged deviation. The proposed area-weighted spatial interpretation provides a quantitative basis for relating the nominal external heat flux established at the specimen center to the spatially averaged external heat flux over the specimen under the ISO 5660-1 cone calorimeter configuration.

  • Open Access

    Effects of External Heat Flux and Exhaust Flow Rate on CO and Soot Yields of Acrylic in a Cone Calorimeter

    by Sun-Yeo Mun, Jae-Ho Cho, Cheol-Hong Hwang

    The effects of changes in irradiance level (external heat flux), exhaust flow rate, and hood height on CO and soot yield were examined using a cone calorimeter. Black acrylic, having similar constituents as polymethyl methacrylate, was used as a combustible, and external heat fluxes ranging from 15 to 65 kW/m2 were considered. Both auto and spark ignitions were applied as ignition methods. The difference in auto and spark ignition methods had no effect on CO and soot yields, or on the mass loss rate (MLR), heat release rate (HRR), and effective heat of combustion (EHC), which are global parameters of fire. As the external heat flux increased, the mean MLR and HRR linearly increased while the EHC remained constant. When the external heat flux increased, the mean mass flow rates of CO and CO2 had a directly proportional relationship with the mean MLR. Consequently, CO and CO2 yields remained constant regardless of the external heat flux. In contrast, the mean mass flow rate and mean MLR of soot were linearly proportional as opposed to directly proportional, and the soot yield thus increased linearly with external heat flux. Variations in the exhaust flow rate and hood height, which can alter the velocity and temperature fields in post-flame and plume regions, had almost no impact on CO and soot yields, as well as on MLR and HRR. The results of this study are expected to provide improved insight into conventional approaches on the recognition of CO and soot yields as unique properties of each combustible.