Michelangelo Di Giuseppe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michelangelo Di Giuseppe has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Brett J. Green
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA
1 shared publication - Brooke Vollmer
National Personal Protective Technology Laboratory, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health
1 shared publication - Christine Niemeier-Walsh
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226, USA
1 shared publication - Christopher C. Coffey
National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, PA 15236, USA
1 shared publication Edward M. Fisher
National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
1 shared publicationJonisha Patrice Pollard
National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
1 shared publication
Latest Publications
- 22 December 2025
- Published by Emerald Publishing in International Journal of Clothing Science and Technology
- Vol. 38 (2) , 334-342
Evaluation of the applicability of viable quantitative real time-PCR (v-qPCR) to expedite viral penetration resistance assessment of personal protective equipment
Purpose: In the USA, personal protective equipment (PPE) that claims to resist viral penetration, must pass the American Society for Testing and Materials (ASTM) F1671 test method which uses a standard plaque assay (SPA) to quantify Phi-X174 virus. SPA is labor-intensive, time-consuming, limiting its practicality for rapid screening. This study evaluates whether a viable quantitative Real-time Poly-merase Chain Reaction (v-qPCR), targeting two amplicon size (332bp, and 1644bp) can serve as a rapid screening tool for PPE during shortages. Design/methodology/approach: Phi-X174 was subjected to heat and UVC treatments known to damage viral capsids and/or genomes. Samples were treated with propidium monoazide (PMA), and viral quantities were assessed using v-qPCR and SPA. Quantification outcomes from v-qPCR were compared against SPA titers. Findings: v-qPCR targeting the 332 bp fragment produced quantification results consistent with SPA, with the greatest difference being about one order of magnitude (3.99×10ˆ10± 4.09×10ˆ9 Particle-Forming Unit/ml (PFU/ml) vs. 2.98×10ˆ9 ± 1.80×10ˆ9 PFU/mL). The v-qPCR method demonstrated a limit of detection of 500 viral copies for the 332 bp target. The 1644 bp amplicon showed higher variability and lower sensitivity. Originality/value: This study is the first to assess v-qPCR's potential for PPE testing by evaluating amplicon size effects and comparing quantification to SPA under standardized damaging conditions. The results suggest that v-qPCR offers a practical screening alternative to support rapid PPE evaluation.
- 22 December 2025
- Published by Emerald Publishing in International Journal of Clothing Science and Technology
- Vol. 38 (2) , 334-342
Evaluation of the applicability of viable quantitative real time-PCR (v-qPCR) to expedite viral penetration resistance assessment of personal protective equipment
Purpose: In the USA, personal protective equipment (PPE) that claims to resist viral penetration, must pass the American Society for Testing and Materials (ASTM) F1671 test method which uses a standard plaque assay (SPA) to quantify Phi-X174 virus. SPA is labor-intensive, time-consuming, limiting its practicality for rapid screening. This study evaluates whether a viable quantitative Real-time Poly-merase Chain Reaction (v-qPCR), targeting two amplicon size (332bp, and 1644bp) can serve as a rapid screening tool for PPE during shortages. Design/methodology/approach: Phi-X174 was subjected to heat and UVC treatments known to damage viral capsids and/or genomes. Samples were treated with propidium monoazide (PMA), and viral quantities were assessed using v-qPCR and SPA. Quantification outcomes from v-qPCR were compared against SPA titers. Findings: v-qPCR targeting the 332 bp fragment produced quantification results consistent with SPA, with the greatest difference being about one order of magnitude (3.99×10ˆ10± 4.09×10ˆ9 Particle-Forming Unit/ml (PFU/ml) vs. 2.98×10ˆ9 ± 1.80×10ˆ9 PFU/mL). The v-qPCR method demonstrated a limit of detection of 500 viral copies for the 332 bp target. The 1644 bp amplicon showed higher variability and lower sensitivity. Originality/value: This study is the first to assess v-qPCR's potential for PPE testing by evaluating amplicon size effects and comparing quantification to SPA under standardized damaging conditions. The results suggest that v-qPCR offers a practical screening alternative to support rapid PPE evaluation.
- Open Access
- 7 June 2024
- Published by Emerald Publishing in International Journal of Clothing Science and Technology
- Vol. 36 (3) , 385-392
Viewpoint: Can qPCR replace the standard plaque assay in the ASTM F1671 to assess personal protective equipment barrier performance?
Viewpoint: Can qPCR replace the standard plaque assay in the ASTM F1671 to assess personal protective equipment barrier performance? - Author: Michelangelo Di Giuseppe, Edward M. Fisher, Lee Greenawald, Jonisha Patrice Pollard
- 7 June 2024
- Published by Emerald Publishing in International Journal of Clothing Science and Technology
- Vol. 36 (3) , 385-392
Open AccessViewpoint: Can qPCR replace the standard plaque assay in the ASTM F1671 to assess personal protective equipment barrier performance?
Viewpoint: Can qPCR replace the standard plaque assay in the ASTM F1671 to assess personal protective equipment barrier performance? - Author: Michelangelo Di Giuseppe, Edward M. Fisher, Lee Greenawald, Jonisha Patrice Pollard
- Open Access
- 26 June 2021
- Published by MDPI AG in Journal of Fungi
- Vol. 7 (7) , 510
Occupational Histoplasmosis: Epidemiology and Prevention Measures
In areas where Histoplasma is endemic in the environment, occupations involving activities exposing workers to soil that contains bird or bat droppings may pose a risk for histoplasmosis. Occupational exposures are frequently implicated in histoplasmosis outbreaks. In this paper, we review the literature on occupationally acquired histoplasmosis. We describe the epidemiology, occupational risk factors, and prevention measures according to the hierarchy of controls.
- 26 June 2021
- Published by MDPI AG in Journal of Fungi
- Vol. 7 (7) , 510
Open AccessOccupational Histoplasmosis: Epidemiology and Prevention Measures
In areas where Histoplasma is endemic in the environment, occupations involving activities exposing workers to soil that contains bird or bat droppings may pose a risk for histoplasmosis. Occupational exposures are frequently implicated in histoplasmosis outbreaks. In this paper, we review the literature on occupationally acquired histoplasmosis. We describe the epidemiology, occupational risk factors, and prevention measures according to the hierarchy of controls.