Lucrezia Zerillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lucrezia Zerillo has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Immacolata Polvere
Department of Science and Technologies, University of Sannio, 82100 Benevento, Italy
4 shared publications - Pasquale Vito
Department of Science and Technology (DST), University of Sannio, 82100 Benevento, BN, Italy
4 shared publications - Tiziana Zotti
Dipartimento di Scienze e Tecnologie, Università degli Studi del Sannio, Benevento, Italy
4 shared publications - Jessica Raffaella Madera
Dipartimento di Scienze e Tecnologie, Università degli Studi del Sannio, Via dei Mulini, 82100 Benevento, Italy
3 shared publications - Romualdo Varricchio
Dipartimento di Scienze, Universit Roma Tre, Rome, Italy
3 shared publications - Serena Voccola
Consorzio Sannio Tech, Apollosa, Italy
3 shared publications
Latest Publications
- Open Access
- 1 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1447
A Novel Ophthalmic Solution Containing Glicopro® Complex for the Treatment of Patients with Dry Eye Disease: Results from a Pilot Study
(1) Background: Dry eye disease (DED) is a multifactorial ocular surface disease characterized by an imbalance in ocular surface homeostasis, and tear substitutes constitute the first line of treatment. The present study aimed to evaluate the changes in the signs and symptoms of patients with DED treated with a novel tear substitute containing the GlicoPro® complex. (2) Methods: Patients with DED not successfully responding to other tear substitutes were enrolled and treated with a novel ophthalmic solution (two drops four times daily). Patients were examined before starting the study treatment (T0) and after 30 (T1) and 60 (T2) days of treatment by means of Keratograph for the evaluation of the following: (i) tear meniscus height (TMH); (ii) noninvasive Keratograph break-up time (NIKBUT); (iii) bulbar redness; and (iv) infrared meibography. The SANDE questionnaire was administered to assess ocular discomfort symptoms. Analysis of the tear content of proenkephalin and Met/Leu-enkephalin was also performed. (3) Results: At T2, a significant improvement in NIKBUT first, average, and class, TMH, and SANDE score was found. The tear content of proenkephalins was significantly higher at T1, whereas processed active Met/Leu-enkephalins increased at both T1 and T2. (4) Conclusions: Our novel tear substitute based on GlicoPro® resulted in a significant improvement in ocular discomfort symptoms, tear volume, and stability in the patients treated. The increase in active peptides processed in tears may represent the pathophysiological substrate underlying this finding.
- 1 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1447
Open AccessA Novel Ophthalmic Solution Containing Glicopro® Complex for the Treatment of Patients with Dry Eye Disease: Results from a Pilot Study
(1) Background: Dry eye disease (DED) is a multifactorial ocular surface disease characterized by an imbalance in ocular surface homeostasis, and tear substitutes constitute the first line of treatment. The present study aimed to evaluate the changes in the signs and symptoms of patients with DED treated with a novel tear substitute containing the GlicoPro® complex. (2) Methods: Patients with DED not successfully responding to other tear substitutes were enrolled and treated with a novel ophthalmic solution (two drops four times daily). Patients were examined before starting the study treatment (T0) and after 30 (T1) and 60 (T2) days of treatment by means of Keratograph for the evaluation of the following: (i) tear meniscus height (TMH); (ii) noninvasive Keratograph break-up time (NIKBUT); (iii) bulbar redness; and (iv) infrared meibography. The SANDE questionnaire was administered to assess ocular discomfort symptoms. Analysis of the tear content of proenkephalin and Met/Leu-enkephalin was also performed. (3) Results: At T2, a significant improvement in NIKBUT first, average, and class, TMH, and SANDE score was found. The tear content of proenkephalins was significantly higher at T1, whereas processed active Met/Leu-enkephalins increased at both T1 and T2. (4) Conclusions: Our novel tear substitute based on GlicoPro® resulted in a significant improvement in ocular discomfort symptoms, tear volume, and stability in the patients treated. The increase in active peptides processed in tears may represent the pathophysiological substrate underlying this finding.
- Open Access
- 7 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 650
Evaluation of FAST COVID-19 SARS-CoV-2 Antigen Rapid Test Kit for Detection of SARS-CoV-2 in Respiratory Samples from Mildly Symptomatic or Asymptomatic Patients
Molecular tests are the gold standard to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection but are associated with a diagnostic delay, while antigen detection tests can generate results within 20 min even outside a laboratory. In order to evaluate the accuracy and reliability of the FAST COVID-19 SARS-CoV-2 Antigen Rapid Test Kit (Ag-RDT), two respiratory swabs were collected simultaneously from 501 patients, with mild or no coronavirus disease 2019 (COVID-19)-related symptoms, and analyzed with both the Reverse Transcriptase-quantitative Polymerase Chain Reaction (RT-qPCR) and the FAST COVID-19 SARS-CoV-2 Antigen Rapid Test. Results were then compared to determine clinical performance in a screening setting. We measured a precision of 97.41% (95% CI 92.42–99.15%) and a recall of 98.26% (95% CI 93.88–99.25%), with a specificity of 99.22% (95% CI 97.74–99.74%), a negative predictive value of 99.48% (95% CI 97.98–99.87%), and an overall accuracy of 99.00% (95% CI 97.69–99.68%). Concordance was described by a Kappa coefficient of 0.971 (95% CI 0.947–0.996). Considering short lead times, low cost, and opportunities for decentralized testing, the Ag-RDT test can enhance the efforts to control SARS-CoV-2 spread in several settings.
- 7 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 650
Open AccessEvaluation of FAST COVID-19 SARS-CoV-2 Antigen Rapid Test Kit for Detection of SARS-CoV-2 in Respiratory Samples from Mildly Symptomatic or Asymptomatic Patients
Molecular tests are the gold standard to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection but are associated with a diagnostic delay, while antigen detection tests can generate results within 20 min even outside a laboratory. In order to evaluate the accuracy and reliability of the FAST COVID-19 SARS-CoV-2 Antigen Rapid Test Kit (Ag-RDT), two respiratory swabs were collected simultaneously from 501 patients, with mild or no coronavirus disease 2019 (COVID-19)-related symptoms, and analyzed with both the Reverse Transcriptase-quantitative Polymerase Chain Reaction (RT-qPCR) and the FAST COVID-19 SARS-CoV-2 Antigen Rapid Test. Results were then compared to determine clinical performance in a screening setting. We measured a precision of 97.41% (95% CI 92.42–99.15%) and a recall of 98.26% (95% CI 93.88–99.25%), with a specificity of 99.22% (95% CI 97.74–99.74%), a negative predictive value of 99.48% (95% CI 97.98–99.87%), and an overall accuracy of 99.00% (95% CI 97.69–99.68%). Concordance was described by a Kappa coefficient of 0.971 (95% CI 0.947–0.996). Considering short lead times, low cost, and opportunities for decentralized testing, the Ag-RDT test can enhance the efforts to control SARS-CoV-2 spread in several settings.
- Open Access
A Peptide-Based Assay Discriminates Individual Antibody Response to the COVID-19 Pfizer/BioNTech mRNA Vaccine
The coronavirus disease 2019 (COVID-19) mRNA vaccine developed by Pfizer/BioNTech has been shown to be capable of developing an excellent antibody response against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, with good production of neutralizing antibodies. Herein, we analyzed differences in the antibody response elicited by inoculation of the Pfizer/BioNTech vaccine through a peptide-based enzyme-linked immunosorbent assay (ELISA) that utilizes synthetic peptides derived from the spike protein in the immuno-adsorbent phase. Immunoreactivity against synthetic peptides was measured at different time points from vaccination and was also correlated with the SARS-CoV-2 neutralizing capacity. Our results indicate that all vaccinated subjects except one show reactive antibodies to at least one peptide at both 30 and 60 days after injection of the first dose. Only one of the 19 analyzed subjects showed no antibody response toward any of the selected peptides, consistently with a lower neutralizing capacity. More importantly, our data showed that the antibody response elicited by inoculation of the two doses of the Pfizer vaccine appears to be qualitatively individual, both in the type of recognized peptides and in the temporal persistence of the antibody response. Together with previous published data, our findings suggest that for effective pandemic control, it is important to constantly monitor the antibody protection in the population, and the assay described here could be a valid tool for this purpose.
Open AccessA Peptide-Based Assay Discriminates Individual Antibody Response to the COVID-19 Pfizer/BioNTech mRNA Vaccine
The coronavirus disease 2019 (COVID-19) mRNA vaccine developed by Pfizer/BioNTech has been shown to be capable of developing an excellent antibody response against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, with good production of neutralizing antibodies. Herein, we analyzed differences in the antibody response elicited by inoculation of the Pfizer/BioNTech vaccine through a peptide-based enzyme-linked immunosorbent assay (ELISA) that utilizes synthetic peptides derived from the spike protein in the immuno-adsorbent phase. Immunoreactivity against synthetic peptides was measured at different time points from vaccination and was also correlated with the SARS-CoV-2 neutralizing capacity. Our results indicate that all vaccinated subjects except one show reactive antibodies to at least one peptide at both 30 and 60 days after injection of the first dose. Only one of the 19 analyzed subjects showed no antibody response toward any of the selected peptides, consistently with a lower neutralizing capacity. More importantly, our data showed that the antibody response elicited by inoculation of the two doses of the Pfizer vaccine appears to be qualitatively individual, both in the type of recognized peptides and in the temporal persistence of the antibody response. Together with previous published data, our findings suggest that for effective pandemic control, it is important to constantly monitor the antibody protection in the population, and the assay described here could be a valid tool for this purpose.
- Open Access
- 26 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1166
Sample-Pooling Strategy for SARS-CoV-2 Detection among Students and Staff of the University of Sannio
Since the beginning of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic, it has been clear that testing large groups of the population was the key to stem infection and prevent the effects of the coronavirus disease of 2019, mostly among sensitive patients. On the other hand, time and cost-sustainability of virus detection by molecular analysis such as reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) may be a major issue if testing is extended to large communities, mainly asymptomatic large communities. In this context, sample-pooling and test grouping could offer an effective solution. Here we report the screening on 1195 oral-nasopharyngeal swabs collected from students and staff of the Università degli Studi del Sannio (University of Sannio, Benevento, Campania, Italy) and analyzed by an in-house developed multiplex RT-qPCR for SARS-CoV-2 detection through a simple monodimensional sample pooling strategy. Overall, 400 distinct pools were generated and, within 24 h after swab collection, five positive samples were identified. Out of them, four were confirmed by using a commercially available kit suitable for in vitro diagnostic use (IVD). High accuracy, sensitivity and specificity were also determined by comparing our results with a reference IVD assay for all deconvoluted samples. Overall, we conducted 463 analyses instead of 1195, reducing testing resources by more than 60% without lengthening diagnosis time and without significant losses in sensitivity, suggesting that our strategy was successful in recognizing positive cases in a community of asymptomatic individuals with minor requirements of reagents and time when compared to normal testing procedures.
- 26 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1166
Open AccessSample-Pooling Strategy for SARS-CoV-2 Detection among Students and Staff of the University of Sannio
Since the beginning of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic, it has been clear that testing large groups of the population was the key to stem infection and prevent the effects of the coronavirus disease of 2019, mostly among sensitive patients. On the other hand, time and cost-sustainability of virus detection by molecular analysis such as reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) may be a major issue if testing is extended to large communities, mainly asymptomatic large communities. In this context, sample-pooling and test grouping could offer an effective solution. Here we report the screening on 1195 oral-nasopharyngeal swabs collected from students and staff of the Università degli Studi del Sannio (University of Sannio, Benevento, Campania, Italy) and analyzed by an in-house developed multiplex RT-qPCR for SARS-CoV-2 detection through a simple monodimensional sample pooling strategy. Overall, 400 distinct pools were generated and, within 24 h after swab collection, five positive samples were identified. Out of them, four were confirmed by using a commercially available kit suitable for in vitro diagnostic use (IVD). High accuracy, sensitivity and specificity were also determined by comparing our results with a reference IVD assay for all deconvoluted samples. Overall, we conducted 463 analyses instead of 1195, reducing testing resources by more than 60% without lengthening diagnosis time and without significant losses in sensitivity, suggesting that our strategy was successful in recognizing positive cases in a community of asymptomatic individuals with minor requirements of reagents and time when compared to normal testing procedures.