KKKenta Kakiuchi

Kenta Kakiuchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kenta Kakiuchi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Lipid Composition and Stirring Dynamics on Oxygen Microbubble Stability and Oxygen Release

    by Kenta Kakiuchi, Mark Andrew Borden

    Lipid-coated oxygen microbubbles (OMBs) are being investigated for biomedical applications to alleviate hypoxia such as systemic oxygenation and image-guided radiosensitization therapy. Additionally, they hold potential for boarder application as oxygen carriers beyond the biomedical filed. Understanding the stability and oxygen release properties of OMBs in dynamic aqueous environments is critical for these applications. In this study, we found that OMBs composed of longer acyl chain phospholipids (DSPC and DBPC) were stable in storage for at least 1 week, unlike the shorter acyl chain phospholipid (DPPC). OMBs were also more stable with a diacyl PEG-PE emulsifier compared with single-chain PEG-40 stearate. Dilution of OMBs did not alter the average diameter. While previous studies have examined the theoretical and experimental aspects of oxygen release from OMBs under static conditions, quantitative evaluations of OMB dispersions under dynamic stirring conditions remain limited. Here, we introduce a novel oxygen measurement method that quantitatively tracks the transition of the dissolved oxygen concentration in an aqueous medium upon mixing with a bolus of OMBs. Our results indicate that a 50 vol % OMB dispersion releases more than 330 mg/L of oxygen, surpassing arterial oxygen levels, and that more than 95% of this oxygen is released within 30 s. The rate of oxygenation of the OMB dispersions was comparable to that of a bolus injection of oxygen-saturated water under sufficient agitation, indicating that convection in the aqueous medium is the limiting transport mechanism. However, the lipid shell had a measurable effect on the oxygen release rate, which correlated with its oxygen permeability. Increasing the stirring speed increased both oxygen release rate and total amount of oxygen released. Overall, this study elucidates the fundamental stability and mass transport properties of the OMB dispersions under practical stirring conditions.

  • Open Access

    Peritoneal Infusion of Oxygen Microbubbles Alters the Metabolomic Profile of the Lung and Spleen in Acute Hypoxic Exposure

    by Christina Lisk, Alex Fan, Francesca I. Cendali, Kenta Kakiuchi, Delaney Swindle, David I. Pak, Robert Tolson, Abby Grier, Keely Buesing, Seth Zaeske, et al.

    Administration of oxygen microbubbles (OMBs) has been shown to increase oxygen and decrease carbon dioxide in systemic circulation, as well as reduce lung inflammation and promote survival in preclinical models of hypoxia caused by lung injury. However, their impact on microenvironmental oxygenation remains unexplored. Herein, we investigated the effects of intraperitoneal administration of OMBs in anesthetized rats exposed to hypoxic ventilation (FiO2 = 0.14). Blood oxygenation and hemodynamics were evaluated over a 2 h time frame, and then organ and tissue samples were collected for hypoxic and metabolic analyses. Data showed that OMBs improved blood SaO2 (~14%) and alleviated tissue hypoxia within the microenvironment of the kidney and intestine at 2 h of hypoxia. Metabolomic analysis revealed OMBs induced metabolic differences in the cecum, liver, kidney, heart, red blood cells and plasma. Within the spleen and lung, principal component analysis showed a metabolic phenotype more comparable to the normoxic group than the hypoxic group. In the spleen, this shift was characterized by reduced levels of fatty acids and 2-hydroxygluterate, alongside increased expression of antioxidant enzymes such as glutathione and hypoxanthine. Interestingly, there was also a shuttle effect within the metabolism of the spleen from the tricarboxylic acid cycle to the glycolysis and pentose phosphate pathways. In the lung, metabolomic analysis revealed upregulation of phosphatidylethanolamine and phosphatidylcholine synthesis, indicating a potential indirect mechanism through which OMB administration may improve lung surfactant secretion and prevent alveolar collapse. In addition, cell-protective purine salvage was increased within the lung. In summary, oxygenation with intraperitoneal OMBs improves systemic blood and local tissue oxygenation, thereby shifting metabolomic profiles of the lung and spleen toward a healthier normoxic state.


  • Open Access

    Fabrication and characterization of a microreactor made of Pd-loaded carbonized tracheids thin plates (CTP)

    by Kenta Kakiuchi, Masamichi Sato, Masao Kitajima, Morihiro Hotta, Shinji Takeoka


  • Do Ultrafine Bubbles Work as Oxygen Carriers?

    by Kenta Kakiuchi, Tomoki Kozuka, Nobuyuki Mase, Takehiro Miyasaka, Norikazu Harii, Shinji Takeoka

    Fine bubbles (FBs) are bubbles with sizes less than 100 μm and are divided into ultrafine bubbles (UFBs, < 1 μm) and microbubbles (MBs, 1-100 μm) depending on their size. Although FB aeration is known as a more efficient way than macrobubble aeration to increase the oxygen level in unoxygenated water, few reports have demonstrated whether dispersed UFBs work as oxygen carriers or not. Furthermore, oxygen supersaturation is one of the attractive characteristics of FB dispersion, but the reason is yet to be revealed. In this study, we evaluated the relationship between the FBs, especially UFB concentration, and oxygen content in several situations to reveal the two questions. The FB concentration and oxygen content were examined using particle analyzers and our developed oxygen measurement method, which can measure the oxygen content in FB dispersion, respectively. First, in the evaluations of the oxygen dispersion from UFBs with respect to the surrounding oxygen level, UFBs did become neither small nor diminish even in degassed water. Second, the changes in UFBs and oxygen content upon storage temperature and the existence of a lid during storage were evaluated, and there was no correlation between them. It means UFBs contribute little to the oxygen content in UFB dispersion. Furthermore, the oxygen content in the UFB dispersion decreased over time identically as that of the oxygen-supersaturated water with little UFBs. Third, we evaluated the relationship between FB concentration and oxygen content during FB generation by measuring them simultaneously. The results showed that dispersed MB and UFB concentrations did not account for the supersaturation of the FB dispersion. From the result, it was revealed that 100-200 nm of UFBs themselves did not work as oxygen carriers, and the oxygen supersaturation in FB dispersions was due to the supersaturated state of dissolved oxygen that was prepared during the FB generation process.


  • Open Access

    Development of quantitative and concise measurement method of oxygen in fine bubble dispersion

    by Kenta Kakiuchi, Takehiro Miyasaka, Norikazu Harii, Shinji Takeoka

    Fine bubbles (FBs) have attracted significant attention in several research fields. Although some reports have argued that FB dispersion is useful as an oxygen (gas) carrier, only a few reports have examined its properties as an oxygen carrier using experimental data. As one of the reasons for this, there are no standard methods for measuring the oxygen content in FB dispersions. Conventional oxygen measurement methods have certain drawbacks in accuracy or speed; thus, it is difficult to use oxygen content as the primary outcome. In this study, we introduce a Clark-type polarographic oxygen electrode device (OXYG1-PLUS) for oxygen measurement, allowing the dilution of FB dispersion without the influence of ambient air and the adhesion of FBs on the electrode surface due to its special shape. First, the accuracy of our dilution method was evaluated using pure water as a sample, and it was confirmed that our method could measure with an accuracy of ±0.5 mg/L from the results with conventional dissolved oxygen meters. Second, the oxygen content in FB dispersion was evaluated with our method and a chemical titration method (Winkler’s method), and it was found that our method could measure the oxygen content in FB dispersions quantitively. This method satisfies the easiness (4 steps) and quickness (within 8 min) for a wide range of oxygen contents (0 to 332 mg/L, theoretical range) with low coefficient variation (< 4.7%) and requires a small sample volume (50–500 μL); thus, it is a useful method for measuring the oxygen in FB dispersions.


  • Establishment of a total liquid ventilation system using saline-based oxygen micro/nano-bubble dispersions in rats

    by Kenta Kakiuchi, Kenichi Matsuda, Norikazu Harii, Keitaro Sou, Junko Aoki, Shinji Takeoka