Shaimaa Abdul-Rahman Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaimaa Abdul-Rahman Ahmed has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hasan F. Makki
Chemical Engineering Department, College of Engineering, University of Baghdad, Baghdad, Iraq
4 shared publications- Forat Yasir AlJaberi
Chemical Engineering Department, College of Engineering, Al-Muthanna University, Al- Muthanna, Iraq
2 shared publications - Fatima H. Mohammed
Chemical Engineering Department, College of Engineering, University of Baghdad, Baghdad, Iraq
1 shared publication Sheam B. Abdul Kareem
Al Farabi University College, Iraq
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 27 (3) , 107-125
Assessing the impact of dye characteristics on electrocoagulation efficiency in synthetic textile wastewater: An RSM-based study
This new study investigates the effect that dye type cationic Methylene Blue (MB) and anionic Congo red (CR) that has on the Electro-coagulation (EC) treatment performance of synthetic wastewater by employing Response Surface Methodology-Central composite design (RSM- CCD) optimization technique. Twenty-seven experiments were performed to analyze and optimize the effects of 4 factors: Current Density (mA/cm²) = 6.67 - 13.33; Initial pH = 2 – 10; Reaction Time (h) = 0.07 – 1.5; and Chemical Oxygen Demand (COD mg /L) = 840 – 4236.67 mg/L. The efficiency of EC treatment is evaluated in terms of COD reduction as primary response variable. The RSM model accomplish an excellent predictive power (R2=98.84%; adjusted R2=97.48%); the experimental results illustrated a significant relationship between the estimated and measured values. The ANOVA analysis indicated that both current density and reaction time were primarily responsible for the most considerable effects on COD reduction. Furthermore, the study found that the initial pH had a critical role in forming and maintaining coagulating species. A maximum COD reduction efficiency of 98.14% was obtained under the best operating conditions as follows; current density of 11.11 mA/cm²(optimal), pH = 6 (initial) and reaction time = 1.5h and initial COD concentration of 2510 mg/L which also utilized only 8.89Wh / kg COD of the applied electrical energy. Many responses also had been tracked in this study to reflect the complex interaction between the operational variables and the final solution properties and its characteristics. The investigated properties changes were the final temperature, conductivity, voltage of the solution, in addition to the theoretical consumption of anode and specific energy consumption. A complex synergistic effect had been reported during the track of the solution characteristic, and this can be relied on the effect of dyes negative and positive charges that reflect some unusual behavior in comparison to the removal of single dyes, or dyes mixture of the same type.
- 30 September 2026
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 27 (3) , 107-125
Open AccessAssessing the impact of dye characteristics on electrocoagulation efficiency in synthetic textile wastewater: An RSM-based study
This new study investigates the effect that dye type cationic Methylene Blue (MB) and anionic Congo red (CR) that has on the Electro-coagulation (EC) treatment performance of synthetic wastewater by employing Response Surface Methodology-Central composite design (RSM- CCD) optimization technique. Twenty-seven experiments were performed to analyze and optimize the effects of 4 factors: Current Density (mA/cm²) = 6.67 - 13.33; Initial pH = 2 – 10; Reaction Time (h) = 0.07 – 1.5; and Chemical Oxygen Demand (COD mg /L) = 840 – 4236.67 mg/L. The efficiency of EC treatment is evaluated in terms of COD reduction as primary response variable. The RSM model accomplish an excellent predictive power (R2=98.84%; adjusted R2=97.48%); the experimental results illustrated a significant relationship between the estimated and measured values. The ANOVA analysis indicated that both current density and reaction time were primarily responsible for the most considerable effects on COD reduction. Furthermore, the study found that the initial pH had a critical role in forming and maintaining coagulating species. A maximum COD reduction efficiency of 98.14% was obtained under the best operating conditions as follows; current density of 11.11 mA/cm²(optimal), pH = 6 (initial) and reaction time = 1.5h and initial COD concentration of 2510 mg/L which also utilized only 8.89Wh / kg COD of the applied electrical energy. Many responses also had been tracked in this study to reflect the complex interaction between the operational variables and the final solution properties and its characteristics. The investigated properties changes were the final temperature, conductivity, voltage of the solution, in addition to the theoretical consumption of anode and specific energy consumption. A complex synergistic effect had been reported during the track of the solution characteristic, and this can be relied on the effect of dyes negative and positive charges that reflect some unusual behavior in comparison to the removal of single dyes, or dyes mixture of the same type.
- Open Access
Electrocoagulation treatment of high saline oily wastewater: evaluation and optimization
- 25 March 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2213 (1) , 020156
Investigation hydraulic performance of splash fills packing in cooling tower
Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experimentally. The tower filled with splash packing with Zig-Zag pattern. Current study used treated waste water and focused fundamentally on the influence of air and water flow rates on hydraulic features of cooling tower for different access water temperatures. The dependency between pressure drop and the air and water flux was spotted. In this study, it found that within a certain ranges the pressure drop increases by 75% due to liquid flux and 70% due to air flux while pressure drop is not affected by changing temperature at all. Two empirical correlation had been founded for dry pressure drop (with R2=99.5%), and for wet pressure drop (with R2=98.13%).
- 25 March 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2213 (1) , 020156
Investigation hydraulic performance of splash fills packing in cooling tower
Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experimentally. The tower filled with splash packing with Zig-Zag pattern. Current study used treated waste water and focused fundamentally on the influence of air and water flow rates on hydraulic features of cooling tower for different access water temperatures. The dependency between pressure drop and the air and water flux was spotted. In this study, it found that within a certain ranges the pressure drop increases by 75% due to liquid flux and 70% due to air flux while pressure drop is not affected by changing temperature at all. Two empirical correlation had been founded for dry pressure drop (with R2=99.5%), and for wet pressure drop (with R2=98.13%).
- 25 March 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2213 (1) , 020178
Corrosion behavior of mild-steel in cooling towers using high salinity solution
Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in the corrosion rate with increasing the salt content to 3.5% four times compared to that of 0%, but after a critical point (3.5%) the corrosion rate had been decreased to reach a level lower than that of pure water. While increasing the solution flowrate to 2.5 l/min and the temperature to 50ᴼC will increase the corrosion rate by 25 and 20% respectively. From the results, it is obvious that the high concentration (>10%) of NaCl will inhibit the corrosion rate of mild-steel significantly and this prologue the gate to the use of saline instead of fresh water without hesitation.
- 25 March 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2213 (1) , 020178
Corrosion behavior of mild-steel in cooling towers using high salinity solution
Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in the corrosion rate with increasing the salt content to 3.5% four times compared to that of 0%, but after a critical point (3.5%) the corrosion rate had been decreased to reach a level lower than that of pure water. While increasing the solution flowrate to 2.5 l/min and the temperature to 50ᴼC will increase the corrosion rate by 25 and 20% respectively. From the results, it is obvious that the high concentration (>10%) of NaCl will inhibit the corrosion rate of mild-steel significantly and this prologue the gate to the use of saline instead of fresh water without hesitation.
- Open Access
- 25 December 2019
- Published by Journal of Engineering in Journal of Engineering
- Vol. 26 (1) , 174-185
Corrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the precision of the Taguchi design for optimization the corrosion rate in cooling tower with high reliability. The contour plot had been applied to understand how it can be in finding the relation between the corrosion rate and the working parameters of the cooling tower.
- 25 December 2019
- Published by Journal of Engineering in Journal of Engineering
- Vol. 26 (1) , 174-185
Open AccessCorrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the precision of the Taguchi design for optimization the corrosion rate in cooling tower with high reliability. The contour plot had been applied to understand how it can be in finding the relation between the corrosion rate and the working parameters of the cooling tower.