Dirk Duddeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dirk Duddeck has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Florian Beuer
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, Aßmannshauser Str. 4–6, 14197 Berlin, Germany
2 shared publications Florian Tebbel
Mechanical Engineering, Heddesheim, Germany
2 shared publications- Peter Gehrke
Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Goethe University, University Hospital Frankfurt, Frankfurt am Main, Germany
2 shared publications Andreas Kunz
Private Dental Laboratory, Berlin, Germany
1 shared publication- Ann Wennerberg
Department of Prosthodontics/Dental Materials Science Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg Göteborg Sweden
1 shared publication Carsten Fischer
Dental Laboratory, Sirius Ceramics, Frankfurt am Main, Germany
1 shared publication
Latest Publications
- Open Access
- 20 September 2023
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 9 (1) , 1-16
Influence of exposure of customized dental implant abutments to different cleaning procedures: an in vitro study using AI-assisted SEM/EDS analysis
Purpose: Dental implant abutments are defined as medical devices by their intended use. Surfaces of custom-made CAD/CAM two-piece abutments may become contaminated during the manufacturing process in the dental lab. Inadequate reprocessing prior to patient care may contribute to implant-associated complications. Risk-adapted hygiene management is required to meet the requirements for medical devices. Methods: A total of 49 CAD/CAM-manufactured zirconia copings were bonded to prefabricated titanium bases. One group was bonded, polished, and cleaned separately in dental laboratories throughout Germany (LA). Another group was left untreated (NC). Five groups received the following hygiene regimen: three-stage ultrasonic cleaning (CP and FP), steam (SC), argon–oxygen plasma (PL), and simple ultrasonic cleaning (UD). Contaminants were detected using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) and segmented and quantified using interactive machine learning (ML) and thresholding (SW). The data were statistically analysed using non-parametric tests (Kruskal–Wallis test, Dunn’s test). Results: Significant differences in contamination levels with the different cleaning procedures were found (p ≤ 0.01). The FP–NC/LA groups showed the most significant difference in contamination levels for both measurement methods (ML, SW), followed by CP–LA/NC and UD–LA/NC for SW and CP–LA/NC and PL–LA/NC for ML (p ≤ 0.05). EDS revealed organic contamination in all specimens; traces of aluminum, silicon, and calcium were detected. Conclusions: Chemothermal cleaning methods based on ultrasound and argon–oxygen plasma effectively removed process-related contamination from zirconia surfaces. Machine learning is a promising assessment tool for quantifying and monitoring external contamination on zirconia abutments. Graphical
- 20 September 2023
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 9 (1) , 1-16
Open AccessInfluence of exposure of customized dental implant abutments to different cleaning procedures: an in vitro study using AI-assisted SEM/EDS analysis
Purpose: Dental implant abutments are defined as medical devices by their intended use. Surfaces of custom-made CAD/CAM two-piece abutments may become contaminated during the manufacturing process in the dental lab. Inadequate reprocessing prior to patient care may contribute to implant-associated complications. Risk-adapted hygiene management is required to meet the requirements for medical devices. Methods: A total of 49 CAD/CAM-manufactured zirconia copings were bonded to prefabricated titanium bases. One group was bonded, polished, and cleaned separately in dental laboratories throughout Germany (LA). Another group was left untreated (NC). Five groups received the following hygiene regimen: three-stage ultrasonic cleaning (CP and FP), steam (SC), argon–oxygen plasma (PL), and simple ultrasonic cleaning (UD). Contaminants were detected using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) and segmented and quantified using interactive machine learning (ML) and thresholding (SW). The data were statistically analysed using non-parametric tests (Kruskal–Wallis test, Dunn’s test). Results: Significant differences in contamination levels with the different cleaning procedures were found (p ≤ 0.01). The FP–NC/LA groups showed the most significant difference in contamination levels for both measurement methods (ML, SW), followed by CP–LA/NC and UD–LA/NC for SW and CP–LA/NC and PL–LA/NC for ML (p ≤ 0.05). EDS revealed organic contamination in all specimens; traces of aluminum, silicon, and calcium were detected. Conclusions: Chemothermal cleaning methods based on ultrasound and argon–oxygen plasma effectively removed process-related contamination from zirconia surfaces. Machine learning is a promising assessment tool for quantifying and monitoring external contamination on zirconia abutments. Graphical
- Open Access
- 22 August 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (9) , 1280
On the Cleanliness of Different Oral Implant Systems: A Pilot Study
(1) Background: This paper aimed to compare the cleanliness of clinically well-documented implant systems with implants providing very similar designs. The hypothesis was that three well-established implant systems from Dentsply Implants, Straumann, and Nobel Biocare were not only produced with a higher level of surface cleanliness but also provided significantly more comprehensive published clinical documentation than their correspondent look-alike implants from Cumdente, Bioconcept, and Biodenta, which show similar geometry and surface structure. (2) Methods: Implants were analyzed using SEM imaging and energy-dispersive X-ray spectroscopy to determine the elemental composition of potential impurities. A search for clinical trials was carried out in the PubMed database and by reaching out to the corresponding manufacturer. (3) Results: In comparison to their corresponding look-alikes, all implants of the original manufacturers showed—within the scope of this analysis—a surface free of foreign materials and reliable clinical documentation, while the SEM analysis revealed significant impurities on all look-alike implants such as organic residues and unintended metal particles of iron or aluminum. Other than case reports, the look-alike implant manufacturers provided no reports of clinical documentation. (4) Conclusions: In contrast to the original implants of market-leading manufacturers, the analyzed look-alike implants showed significant impurities, underlining the need for periodic reviews of sterile packaged medical devices and their clinical documentation.
- 22 August 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (9) , 1280
Open AccessOn the Cleanliness of Different Oral Implant Systems: A Pilot Study
(1) Background: This paper aimed to compare the cleanliness of clinically well-documented implant systems with implants providing very similar designs. The hypothesis was that three well-established implant systems from Dentsply Implants, Straumann, and Nobel Biocare were not only produced with a higher level of surface cleanliness but also provided significantly more comprehensive published clinical documentation than their correspondent look-alike implants from Cumdente, Bioconcept, and Biodenta, which show similar geometry and surface structure. (2) Methods: Implants were analyzed using SEM imaging and energy-dispersive X-ray spectroscopy to determine the elemental composition of potential impurities. A search for clinical trials was carried out in the PubMed database and by reaching out to the corresponding manufacturer. (3) Results: In comparison to their corresponding look-alikes, all implants of the original manufacturers showed—within the scope of this analysis—a surface free of foreign materials and reliable clinical documentation, while the SEM analysis revealed significant impurities on all look-alike implants such as organic residues and unintended metal particles of iron or aluminum. Other than case reports, the look-alike implant manufacturers provided no reports of clinical documentation. (4) Conclusions: In contrast to the original implants of market-leading manufacturers, the analyzed look-alike implants showed significant impurities, underlining the need for periodic reviews of sterile packaged medical devices and their clinical documentation.
- Open Access
- 26 April 2019
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 33 (3) , 689-698
The Influence of an Ultrasonic Cleaning Protocol for CAD/CAM Abutment Surfaces on Cell Viability and Inflammatory ResponseIn Vitro
Background/Aim: To evaluate the effect of an ultrasonic cleaning and disinfection method for CAD/CAM abutment surfaces on cell viability and inflammatory response in vitro. Materials and Methods: Untreated and manually polished surfaces of CAD/CAM generated titanium and zirconia disks were randomly assigned, either to a 3-step ultrasonic cleaning and disinfection process (test: TiUF, TiPF, ZrUF, ZrPF) or to 30 sec steam cleaning (control: TiUS, TiPS, ZrUS, ZrPS). Pre-cleaning surface analyses using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and surface profilometry were performed. Human gingival fibroblasts (HGFs) were cultured on test and control specimens and subsequently examined for cell viability and inflammatory response. Expression of acute inflammatory cytokine interleukin (IL)-6 and vascular endothelial growth factor A (VEGFA) were assessed by means of RT-qPCR. Results: Cells on all specimens exhibited a satisfactory viability, indicating firm attachment. Cells on polished zirconia samples, cleaned by means of sonication (ZrPF), exhibited significantly higher viability than cells on the same material cleaned by steam (ZrPS), p=0.019. For all other three material/ surface treatment combinations (TiU, TiP, ZrU), no such difference was observed between the cleaning methods. The messenger ribonucleic acid (mRNA) levels of IL-6 and VEGFA were between 50 and 105% of that of the control cells on the non-toxic control surface. mRNA levels of IL-6 and VEGFA correlated well with each other. Conclusion: Except for higher viability of cells cultured on polished zirconia specimens, no universally applicable advantage could be found for the ultrasonic cleaning procedure for zirconia and titanium abutment surfaces regarding cell viability, IL-6 expression or VEGFA expression. The cleaning procedures did not have any negative effect either.
- 26 April 2019
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 33 (3) , 689-698
Open AccessThe Influence of an Ultrasonic Cleaning Protocol for CAD/CAM Abutment Surfaces on Cell Viability and Inflammatory ResponseIn Vitro
Background/Aim: To evaluate the effect of an ultrasonic cleaning and disinfection method for CAD/CAM abutment surfaces on cell viability and inflammatory response in vitro. Materials and Methods: Untreated and manually polished surfaces of CAD/CAM generated titanium and zirconia disks were randomly assigned, either to a 3-step ultrasonic cleaning and disinfection process (test: TiUF, TiPF, ZrUF, ZrPF) or to 30 sec steam cleaning (control: TiUS, TiPS, ZrUS, ZrPS). Pre-cleaning surface analyses using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and surface profilometry were performed. Human gingival fibroblasts (HGFs) were cultured on test and control specimens and subsequently examined for cell viability and inflammatory response. Expression of acute inflammatory cytokine interleukin (IL)-6 and vascular endothelial growth factor A (VEGFA) were assessed by means of RT-qPCR. Results: Cells on all specimens exhibited a satisfactory viability, indicating firm attachment. Cells on polished zirconia samples, cleaned by means of sonication (ZrPF), exhibited significantly higher viability than cells on the same material cleaned by steam (ZrPS), p=0.019. For all other three material/ surface treatment combinations (TiU, TiP, ZrU), no such difference was observed between the cleaning methods. The messenger ribonucleic acid (mRNA) levels of IL-6 and VEGFA were between 50 and 105% of that of the control cells on the non-toxic control surface. mRNA levels of IL-6 and VEGFA correlated well with each other. Conclusion: Except for higher viability of cells cultured on polished zirconia specimens, no universally applicable advantage could be found for the ultrasonic cleaning procedure for zirconia and titanium abutment surfaces regarding cell viability, IL-6 expression or VEGFA expression. The cleaning procedures did not have any negative effect either.
- Open Access
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (3) , 197-204
Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments
Gehrke P, et al. J Adv Prosthodont. 2018 Jun;10(3):197-204. https://doi.org/10.4047/jap.2018.10.3.197
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (3) , 197-204
Open AccessInfluence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments
Gehrke P, et al. J Adv Prosthodont. 2018 Jun;10(3):197-204. https://doi.org/10.4047/jap.2018.10.3.197
- 1 May 2015
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 124 (05) , 210-215
Digital konstruierte wurzelanaloge Implantate
Wurzelanaloge Implantate bieten mit ihrem minimalinvasiven klinischen Prozedere eine interessante Alternative zur herkömmlichen Implantat-Therapie, wenn die Kontraindikationen streng beachtet werden. Ein digital rekonstruiertes Titan-Zirkon-Hybrid-Implantat und ein Vollzirkon-Implantat wurden im Rahmen einer umfassenden Studie zur Qualität dentaler Implantate analysiert. Herstellung und klinisches Procedere werden beispielhaft dargestellt. Root-analogue implants offer with its minimally invasive clinical procedure an attractive alternative to conventional implant therapy when the contraindications are strictly followed. A digitally reconstructed titanium-zirconium hybrid-implant and a zirconium-implant were analyzed in a comprehensive study on the quality of dental implants. Manufacturing and clinical procedure are exemplified.
- 1 May 2015
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 124 (05) , 210-215
Digital konstruierte wurzelanaloge Implantate
Wurzelanaloge Implantate bieten mit ihrem minimalinvasiven klinischen Prozedere eine interessante Alternative zur herkömmlichen Implantat-Therapie, wenn die Kontraindikationen streng beachtet werden. Ein digital rekonstruiertes Titan-Zirkon-Hybrid-Implantat und ein Vollzirkon-Implantat wurden im Rahmen einer umfassenden Studie zur Qualität dentaler Implantate analysiert. Herstellung und klinisches Procedere werden beispielhaft dargestellt. Root-analogue implants offer with its minimally invasive clinical procedure an attractive alternative to conventional implant therapy when the contraindications are strictly followed. A digitally reconstructed titanium-zirconium hybrid-implant and a zirconium-implant were analyzed in a comprehensive study on the quality of dental implants. Manufacturing and clinical procedure are exemplified.