N. Lopez-March
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
N. Lopez-March has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Fergus Wilson
STFC Rutherford Appleton Laboratory
450 shared publications - Claudia Patrignani
INFN Sezione di Bologna
448 shared publications - David Hutchcroft
University of Liverpool
448 shared publications - Eugeni Grauges
ICCUB, Universitat de Barcelona
448 shared publications - Gerhard Raven
Nikhef National Institute for Subatomic Physics and VU University Amsterdam
448 shared publications - Thomas Latham
University of Warwick
448 shared publications
Latest Publications
- Open Access
- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Demonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ .- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Open AccessDemonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ . - Open Access
- 7 September 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (9) , 82
Radon-induced backgrounds in the NEXT-100 experiment
A bstract: The NEXT-100 detector at the LSC aims at the first competitive search for the 0 νββ decay using a high-pressure 136 Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal 222 Rn activity is found to be (0.95 ± 0.04(stat) ± 0.09(sys)) Bq/m 3 , while no traces of 220 Rn have been observed. Most of the 222 Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced 214 Bi of (0.97 ± 0.05(stat) ± 0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0 νββ region of interest is evaluated as (7.3 ± 1.5(stat) ± 0.8(sys)) × 10 − 4 counts/(keV · kg · yr) after selection of the fully contained events. This background index is reduced to ∼ 4 × 10 − 5 counts/(keV · kg · yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.
- 7 September 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (9) , 82
Open AccessRadon-induced backgrounds in the NEXT-100 experiment
A bstract: The NEXT-100 detector at the LSC aims at the first competitive search for the 0 νββ decay using a high-pressure 136 Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal 222 Rn activity is found to be (0.95 ± 0.04(stat) ± 0.09(sys)) Bq/m 3 , while no traces of 220 Rn have been observed. Most of the 222 Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced 214 Bi of (0.97 ± 0.05(stat) ± 0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0 νββ region of interest is evaluated as (7.3 ± 1.5(stat) ± 0.8(sys)) × 10 − 4 counts/(keV · kg · yr) after selection of the fully contained events. This background index is reduced to ∼ 4 × 10 − 5 counts/(keV · kg · yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Open AccessCharge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- Open Access
- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
First results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessFirst results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target. - Open Access
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Measurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessMeasurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- Top Cited PapersOpen Access
- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
Top Cited PapersOpen AccessThe NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget. - Open Access
- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Open AccessPerformance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and . - Open Access
- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Open AccessReconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected. - Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Supernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Open AccessSupernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- Open Access
- 22 October 2019
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2019 (10) , 230
Energy calibration of the NEXT-White detector with 1% resolution near Qββ of 136Xe
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ββ0ν), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ββ0ν searches.
- 22 October 2019
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2019 (10) , 230
Open AccessEnergy calibration of the NEXT-White detector with 1% resolution near Qββ of 136Xe
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ββ0ν), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ββ0ν searches.