Toshihiro Furuta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Toshihiro Furuta has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Hirofumi Fujii
Division of Functional Imaging, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwanoha 6-5-1, Kashiwa, Chiba, 277-8577, Japan
9 shared publicationsKuni Ohtomo
Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
8 shared publicationsManabu Minami
Department of Radiology, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki, 305-8577, Japan
7 shared publications- Masayuki Yamaguchi
Department of Diagnostic Radiology, National Cancer Center Hospital East, Kashiwa, Japan
5 shared publications Masayuki Yamaguchi
Division of Functional Imaging, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwanoha 6-5-1, Kashiwa, Chiba, 277-8577, Japan
4 shared publications- Osamu Abe
The University of Tokyo
4 shared publications
Latest Publications
- 28 January 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (3) , 695-696
Pediatric chordoma – the importance of recognizing the poorly differentiated subtype: Reply to Inarejos et al
- 28 January 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (3) , 695-696
Pediatric chordoma – the importance of recognizing the poorly differentiated subtype: Reply to Inarejos et al
- 22 August 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (12) , 2030-2038.e1
Pulmonary Toxicity of Ethiodized Oil in the Venous Circulation in Mice: Radiological Findings and Pathological Correlation
- 22 August 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (12) , 2030-2038.e1
Pulmonary Toxicity of Ethiodized Oil in the Venous Circulation in Mice: Radiological Findings and Pathological Correlation
- 26 March 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (6) , 453-459
Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study
- 26 March 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (6) , 453-459
Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study
- Open Access
- 1 July 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (7) , 1874-1877
Fat-forming solitary fibrous tumor of the sacrum: A case report and literature review
- 1 July 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (7) , 1874-1877
Open AccessFat-forming solitary fibrous tumor of the sacrum: A case report and literature review
- 4 March 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (5) , 701-712
Treatment margins in radiotherapy for liver tumors visualized as T2*-hypointense areas on SPIO-enhanced MRI at 9.4 T
Objective To investigate whether a SPIO-labeling technique could enable MR visualization of the treatment margin after X-irradiation at a single dose of 30 Gy. Materials and methods Fifteen rats bearing N1-S1 hepatoma in either the left (group 1) or right (group 2) liver lobe were examined. Four hours after systemic SPIO administration, the left lobe was selectively irradiated at 30 Gy. Liver T2* maps were acquired 7 days later using a 9.4 T scanner. The livers were excised and examined histologically. Results The irradiated area showed T2*-weighted hypointensity with significantly shorter T2* values than those in the non-irradiated area (p < 0.001). Tumors in group 1 completely disappeared, whereas tumors in group 2 had grown outside the T2*-weighted hypointensity by up to ~ 2.3 times that at baseline. Group 1 showed significantly higher probability of tumor regression than group 2 (p = 0.048). Histologically, iron deposition was heavier in irradiated areas than in non-irradiated areas. Discussion Even at a single dose of 30 Gy, which is a slightly higher dose than can be used clinically in stereotactic body radiotherapy, MR visualization of the treatment margin was achieved, because tumors showed significant growth outside the T2*-hypointense areas. In contrast, tumors disappeared inside the T2*-hypointense areas.
- 4 March 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (5) , 701-712
Treatment margins in radiotherapy for liver tumors visualized as T2*-hypointense areas on SPIO-enhanced MRI at 9.4 T
Objective To investigate whether a SPIO-labeling technique could enable MR visualization of the treatment margin after X-irradiation at a single dose of 30 Gy. Materials and methods Fifteen rats bearing N1-S1 hepatoma in either the left (group 1) or right (group 2) liver lobe were examined. Four hours after systemic SPIO administration, the left lobe was selectively irradiated at 30 Gy. Liver T2* maps were acquired 7 days later using a 9.4 T scanner. The livers were excised and examined histologically. Results The irradiated area showed T2*-weighted hypointensity with significantly shorter T2* values than those in the non-irradiated area (p < 0.001). Tumors in group 1 completely disappeared, whereas tumors in group 2 had grown outside the T2*-weighted hypointensity by up to ~ 2.3 times that at baseline. Group 1 showed significantly higher probability of tumor regression than group 2 (p = 0.048). Histologically, iron deposition was heavier in irradiated areas than in non-irradiated areas. Discussion Even at a single dose of 30 Gy, which is a slightly higher dose than can be used clinically in stereotactic body radiotherapy, MR visualization of the treatment margin was achieved, because tumors showed significant growth outside the T2*-hypointense areas. In contrast, tumors disappeared inside the T2*-hypointense areas.
- 24 August 2018
- Published by Springer Nature in Neuroradiology
- Vol. 60 (11) , 1141-1150
Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography
To evaluate the effects of the single-energy metal artifact reduction (SEMAR) algorithm on image quality of cerebral CT and CT angiography (CTA) for patients who underwent intracranial aneurysm coiling.
- 24 August 2018
- Published by Springer Nature in Neuroradiology
- Vol. 60 (11) , 1141-1150
Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography
To evaluate the effects of the single-energy metal artifact reduction (SEMAR) algorithm on image quality of cerebral CT and CT angiography (CTA) for patients who underwent intracranial aneurysm coiling.
- 9 January 2017
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (9) , 1085-1093
Full and hybrid iterative reconstruction to reduce artifacts in abdominal CT for patients scanned without arm elevation
Abdominal computed tomography (CT) without arm elevation is associated with degraded image quality due to streak artifacts. To compare the degree of streak artifacts in abdominal CT images without arm elevation between full iterative reconstruction (IR), hybrid IR, and filtered back projection (FBP) using two commercially available scanners. First, a phantom study simulating CT examination without arm elevation was performed. Second, unenhanced axial images of 33 patients (17 and 16 patients for each vendor) who underwent CT without arm elevation were reconstructed with full IR, hybrid IR and FBP. A radiologist placed 50 parallel lines with lengths of 50 pixels vertical to the streaks and quantitatively evaluated the images for streak artifacts in the phantom study. Two radiologists evaluated the images of patients for streak artifacts (on the liver and the kidney) and diagnostic acceptability using a four-point scale. The phantom study indicated that full IR algorithms were more effective than FBP in reducing streak artifacts. In the clinical patient study, streak artifacts were significantly more reduced with full IR compared with FBP in both the liver and kidney (P < 0.012). Streak artifact reduction was limited with hybrid IR. Model-based iterative reconstruction (MBIR) (one of the full IR algorithms) provided diagnostically more acceptable image quality (P < 0.016) compared with FBP. In abdominal CT without arm elevation, full IR enabled a more efficient streak artifact reduction compared with FBP and MBIR was associated with diagnostically more acceptable images.
- 9 January 2017
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (9) , 1085-1093
Full and hybrid iterative reconstruction to reduce artifacts in abdominal CT for patients scanned without arm elevation
Abdominal computed tomography (CT) without arm elevation is associated with degraded image quality due to streak artifacts. To compare the degree of streak artifacts in abdominal CT images without arm elevation between full iterative reconstruction (IR), hybrid IR, and filtered back projection (FBP) using two commercially available scanners. First, a phantom study simulating CT examination without arm elevation was performed. Second, unenhanced axial images of 33 patients (17 and 16 patients for each vendor) who underwent CT without arm elevation were reconstructed with full IR, hybrid IR and FBP. A radiologist placed 50 parallel lines with lengths of 50 pixels vertical to the streaks and quantitatively evaluated the images for streak artifacts in the phantom study. Two radiologists evaluated the images of patients for streak artifacts (on the liver and the kidney) and diagnostic acceptability using a four-point scale. The phantom study indicated that full IR algorithms were more effective than FBP in reducing streak artifacts. In the clinical patient study, streak artifacts were significantly more reduced with full IR compared with FBP in both the liver and kidney (P < 0.012). Streak artifact reduction was limited with hybrid IR. Model-based iterative reconstruction (MBIR) (one of the full IR algorithms) provided diagnostically more acceptable image quality (P < 0.016) compared with FBP. In abdominal CT without arm elevation, full IR enabled a more efficient streak artifact reduction compared with FBP and MBIR was associated with diagnostically more acceptable images.
- 4 July 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 45 (1) , 303-312
Persistent T2*-hypointensity of the liver parenchyma after irradiation to the SPIO-accumulated liver: An imaging marker for responses to radiotherapy in hepatic malignancies
Purpose To determine whether T2*-weighted MRI has the ability to visualize the irradiated liver parenchyma and liver tumor after irradiation to the previously superparamagnetic iron oxide (SPIO)-accumulated liver. Materials and Methods We examined 24 liver tumor-bearing rats. Nine rats (Group 1) received 20 µmol Fe/kg SPIO and subsequent 70-Gy irradiation to the tumor-bearing liver lobe. Four rats (Group 2) received SPIO and sham irradiation. Six rats (Group 3) received saline and irradiation. Finally, five rats (Group 4) received saline and sham irradiation. We acquired sequential 3 Tesla T2*-weighted images of the liver on day 7, and assessed MR image findings including signal intensity of the tumors and tumor-bearing liver lobes. Results In six rats in Group 1, tumors shrunk by 39–100% (303–0 mm3), and severely, well-defined hypointense irradiated areas were observed. In the other two rats, tumors enlarged by 25 and 172% (595 and 1148 mm3), and hypointense rings surrounded the tumors. The normalized relative signal intensity of the irradiated areas was significantly lower than that of the tumor (0.53 ± 0.06 versus 0.94 ± 0.06; P < 0.05). The severely, well-defined hypointense areas were not observed in the other groups. Histologically, necrotic regions dominated and minimal nonnecrotic tumor cells remained in irradiated areas. The number of CD68-positive cells was higher in irradiated areas than in nonirradiated areas. Conclusion T2*-weighted MR imaging visualized the irradiated liver parenchyma as markedly, well-defined hypointense areas and liver cancer lesions as hyperintense areas only when SPIO was administered before irradiation. The visualization of the hypointense area was associated with tumor regression after irradiation. Level of Evidence: 2 J. Magn. Reson. Imaging 2017;45:303–312.
- 4 July 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 45 (1) , 303-312
Persistent T2*-hypointensity of the liver parenchyma after irradiation to the SPIO-accumulated liver: An imaging marker for responses to radiotherapy in hepatic malignancies
Purpose To determine whether T2*-weighted MRI has the ability to visualize the irradiated liver parenchyma and liver tumor after irradiation to the previously superparamagnetic iron oxide (SPIO)-accumulated liver. Materials and Methods We examined 24 liver tumor-bearing rats. Nine rats (Group 1) received 20 µmol Fe/kg SPIO and subsequent 70-Gy irradiation to the tumor-bearing liver lobe. Four rats (Group 2) received SPIO and sham irradiation. Six rats (Group 3) received saline and irradiation. Finally, five rats (Group 4) received saline and sham irradiation. We acquired sequential 3 Tesla T2*-weighted images of the liver on day 7, and assessed MR image findings including signal intensity of the tumors and tumor-bearing liver lobes. Results In six rats in Group 1, tumors shrunk by 39–100% (303–0 mm3), and severely, well-defined hypointense irradiated areas were observed. In the other two rats, tumors enlarged by 25 and 172% (595 and 1148 mm3), and hypointense rings surrounded the tumors. The normalized relative signal intensity of the irradiated areas was significantly lower than that of the tumor (0.53 ± 0.06 versus 0.94 ± 0.06; P < 0.05). The severely, well-defined hypointense areas were not observed in the other groups. Histologically, necrotic regions dominated and minimal nonnecrotic tumor cells remained in irradiated areas. The number of CD68-positive cells was higher in irradiated areas than in nonirradiated areas. Conclusion T2*-weighted MR imaging visualized the irradiated liver parenchyma as markedly, well-defined hypointense areas and liver cancer lesions as hyperintense areas only when SPIO was administered before irradiation. The visualization of the hypointense area was associated with tumor regression after irradiation. Level of Evidence: 2 J. Magn. Reson. Imaging 2017;45:303–312.
- 1 June 2015
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 50 (6) , 376-383
Magnetic Resonance-Based Visualization of Thermal Ablative Margins Around Hepatic Tumors by Means of Systemic Ferucarbotran Administration Before Radiofrequency Ablation
Objective The objective of this study was to demonstrate experimentally that radiofrequency ablation (RFA) of ferucarbotran-accumulated healthy liver tissues causes excess iron deposition in the ablated liver tissues on postablation days and produces sustained T2*-weighted low signals indicative of ablative margins surrounding hepatic tumors. Materials and Methods We conducted 3 experiments using 30 rats. In experiment 1, we administered either ferucarbotran (n = 6) or saline (n = 4), acquired T2*-weighted images (T2*-WIs) of the liver by using a 3-T magnetic resonance scanner, and subsequently performed RFA of healthy liver lobes. We acquired follow-up T2*-WIs up to day 7 and histologically analyzed the liver specimens. In another 4 rats, we performed sham operation, instead of RFA, in ferucarbotran-accumulated liver lobes, followed by the same image acquisition and histological analysis. In experiment 2, we administered 59Fe-labeled ferucarbotran, subsequently performed either RFA (n = 4) or sham operation (n = 4) in the liver, and acquired autoradiograms of the liver specimens on day 7. In experiment 3, we conducted RFA treatment for 8 rats bearing orthotopic hepatic tumors after ferucarbotran administration and monitored tumor growth by using serial T2*-WIs. Results On days 4 and 7 of the experiment 1, T2*-WIs of 6 rats with systemic ferucarbotran administration and subsequent hepatic RFA showed low-signal regions indicative of ablated liver tissues, whereas high-signal areas were seen in 4 saline-administered rats. Neither high nor low signal areas were detected in 4 sham-operated rats. Histologically, larger amounts of iron were observed in the RFA-induced necrotic liver tissues in the ferucarbotran-administered rats than in the saline-administered-rats. The 59Fe autoradiography of the rats in experiment 2 revealed accumulation of ferucarbotran-derived iron in necrotic liver tissues. Among 6 hepatic tumors grown in 6 rats of the experiment 3, a total of 4 tumors were stable in size, but the other 2 increased markedly on day 7. Retrospectively, T2*-WIs showed the former tumor sites surrounded completely by low-signal areas on day 4. Conclusions The RFA of ferucarbotran-accumulated healthy liver tissues in the rats caused excess iron deposition in the ablated liver tissues and produced sustained T2*-weighted hypointense regions. Similar hypointense regions surrounding hepatic tumors were indicative of ablative margins.
- 1 June 2015
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 50 (6) , 376-383
Magnetic Resonance-Based Visualization of Thermal Ablative Margins Around Hepatic Tumors by Means of Systemic Ferucarbotran Administration Before Radiofrequency Ablation
Objective The objective of this study was to demonstrate experimentally that radiofrequency ablation (RFA) of ferucarbotran-accumulated healthy liver tissues causes excess iron deposition in the ablated liver tissues on postablation days and produces sustained T2*-weighted low signals indicative of ablative margins surrounding hepatic tumors. Materials and Methods We conducted 3 experiments using 30 rats. In experiment 1, we administered either ferucarbotran (n = 6) or saline (n = 4), acquired T2*-weighted images (T2*-WIs) of the liver by using a 3-T magnetic resonance scanner, and subsequently performed RFA of healthy liver lobes. We acquired follow-up T2*-WIs up to day 7 and histologically analyzed the liver specimens. In another 4 rats, we performed sham operation, instead of RFA, in ferucarbotran-accumulated liver lobes, followed by the same image acquisition and histological analysis. In experiment 2, we administered 59Fe-labeled ferucarbotran, subsequently performed either RFA (n = 4) or sham operation (n = 4) in the liver, and acquired autoradiograms of the liver specimens on day 7. In experiment 3, we conducted RFA treatment for 8 rats bearing orthotopic hepatic tumors after ferucarbotran administration and monitored tumor growth by using serial T2*-WIs. Results On days 4 and 7 of the experiment 1, T2*-WIs of 6 rats with systemic ferucarbotran administration and subsequent hepatic RFA showed low-signal regions indicative of ablated liver tissues, whereas high-signal areas were seen in 4 saline-administered rats. Neither high nor low signal areas were detected in 4 sham-operated rats. Histologically, larger amounts of iron were observed in the RFA-induced necrotic liver tissues in the ferucarbotran-administered rats than in the saline-administered-rats. The 59Fe autoradiography of the rats in experiment 2 revealed accumulation of ferucarbotran-derived iron in necrotic liver tissues. Among 6 hepatic tumors grown in 6 rats of the experiment 3, a total of 4 tumors were stable in size, but the other 2 increased markedly on day 7. Retrospectively, T2*-WIs showed the former tumor sites surrounded completely by low-signal areas on day 4. Conclusions The RFA of ferucarbotran-accumulated healthy liver tissues in the rats caused excess iron deposition in the ablated liver tissues and produced sustained T2*-weighted hypointense regions. Similar hypointense regions surrounding hepatic tumors were indicative of ablative margins.
- Open Access
- 17 April 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (4) , e94945
Detection of Lung Tumors in Mice Using a 1-Tesla Compact Magnetic Resonance Imaging System
Due to their small size, lung tumors in rodents are typically investigated using high-field magnetic resonance (MR) systems (4.7 T or higher) to achieve higher signal-to-noise ratios, although low-field MR systems are less sensitive to susceptibility artifacts caused by air in the lung. We investigated the feasibility of detecting lung tumors in living, freely breathing mice with a 1-T compact permanent magnet MR system. In total, 4 mice were used, and MR images of mouse lungs were acquired using a T1-weighted three-dimensional fast low-angle shot sequence without cardiac or respiratory gating. The delineation and size of lung tumors were assessed and compared with histopathological findings. Submillimeter lesions were demonstrated as hyperintense, relative to the surrounding lung parenchyma, and were delineated clearly. Among the 13 lesions validated in histopathological sections, 11 were detected in MR images; the MR detection rate was thus 84.6%. A strong correlation was obtained in size measurements between MR images and histological sections. Thus, a dedicated low-field MR system can be used to detect lung tumors in living mice noninvasively without gating.
- 17 April 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (4) , e94945
Open AccessDetection of Lung Tumors in Mice Using a 1-Tesla Compact Magnetic Resonance Imaging System
Due to their small size, lung tumors in rodents are typically investigated using high-field magnetic resonance (MR) systems (4.7 T or higher) to achieve higher signal-to-noise ratios, although low-field MR systems are less sensitive to susceptibility artifacts caused by air in the lung. We investigated the feasibility of detecting lung tumors in living, freely breathing mice with a 1-T compact permanent magnet MR system. In total, 4 mice were used, and MR images of mouse lungs were acquired using a T1-weighted three-dimensional fast low-angle shot sequence without cardiac or respiratory gating. The delineation and size of lung tumors were assessed and compared with histopathological findings. Submillimeter lesions were demonstrated as hyperintense, relative to the surrounding lung parenchyma, and were delineated clearly. Among the 13 lesions validated in histopathological sections, 11 were detected in MR images; the MR detection rate was thus 84.6%. A strong correlation was obtained in size measurements between MR images and histological sections. Thus, a dedicated low-field MR system can be used to detect lung tumors in living mice noninvasively without gating.