SBSaleh Akram Bhuiyan

Saleh Akram Bhuiyan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Saleh Akram Bhuiyan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Bruce P. Lee

    Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan 49931, United States

    3 shared publications
  • H. M. Moshiur Rahman Mondal

    EEE Department, American International University-Bangladesh, Bangladesh

    3 shared publications
  • Rattapol Pinnaratip

    Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA

    2 shared publications
  • Bo Liu

    Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan 49931, United States

    1 shared publication
  • Chito Kendrick

    Department of Electrical Engineering, Michigan Technological University, Houghton, MI, United States

    1 shared publication
  • Elizabeth Polega

    Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, United States

    1 shared publication

Latest Publications

  • ELECTROCHEMICAL APPROACHES TO CONTROL CATECHOL-BASED ADHESION

    by Saleh Akram Bhuiyan

    Catechol molecules in the adhesive proteins secreted by marine mussels are often used to design external stimulus (e.g., pH, temperature, or light)-responsive smart adhesives. Here, we are introducing electricity as an external stimulus to tune the adhesion of these adhesives. Controlling the extent of oxidation of catechol with electricity was the mechanism to tune adhesion. At first, tunable adhesion of a catechol adhesive with 1 - 9 V was obtained in water by utilizing a two-electrode-based (anode and cathode) Johnson–Kendall–Roberts (JKR) contact mechanics test setup. The electricity initiated water electrolysis, elevated pH near the cathode, and oxidized catechol exposed to the cathode to its poorly adhesive quinone form. We established that the applied voltage and current levels, exposure time, and salt concentration of the water were the controlling parameters to tune adhesive properties. However, the rapid deactivation needed elevated voltage due to the poorly conductive adhesive. Moreover, the adhesive was irreversible. Thus, in our second approach, a thin catechol-containing adhesive coating was coated on an aluminum disc, and its conductivity was increased by adding the conductive pyrene monomer. Increased conductivity enabled the deactivation of adhesive with only 1 V. In addition, phenylboronic acid (APBA) was added into the coating to impart reversibility. This coating was reversible after deactivation for up to five cycles utilizing pH-responsive catechol-boronate complexation chemistry. The deactivation process discussed in the last two approaches depended on the conductive surface. Therefore, in our final approach, a catechol adhesive was deactivated by a peripheral silver cathode while in direct contact with a nonconductive glass surface. Based on lap shear tests, deactivation was achieved within 4 min while applying 20 V. The deactivation rate was dependent on the applied voltage level, exposure time, area of the adhesive interface, and conductivity of the surface material. Additionally, electrochemical reversibility of the adhesive up to 3 cycles was obtained by changing electrode polarity and utilizing catechol-boronate complexation chemistry. Overall, this dissertation provides approaches to combine oft-used adhesion testing methods with electrical circuitry to tune the adhesion of catechol adhesives of different formulations and architectures utilizing novel chemistries.

  • In Situ Deactivation of Catechol-Containing Adhesive Using Electrochemistry

    by Saleh Akram Bhuiyan, James D. Roland, Bo Liu, Max Reaume, Zhongtian Zhang, Jonathan D. Kelley, Bruce P. Lee

    Marine mussels secret catechol-containing adhesive proteins that enable these organisms to bind to various surfaces underwater. Synthetic mimics of these proteins have been created to function as adhesives and coatings for a wide range of applications. Here, we demonstrated the use of in situ electrical field stimulation to deactivate the adhesive property of catechol-containing adhesive that is in direct contact with a surface. Johnson–Kendall–Roberts (JKR) contact mechanics test was performed using a titanium (Ti) sphere in the presence of a pH 7.5 aqueous buffer. The Ti sphere also served as a conductive electrode for applying electricity to the adhesive, while a platinum (Pt) wire served as the counter electrode. Work of adhesion (Wadh) decreased with increased levels of applied voltage and current, exposure time to the applied electricity, and salt concentration of the interfacial buffer. Application of 9 V for 1 min completely deactivated the adhesive. UV–vis diffuse reflectance spectra and tracking of catechol oxidation byproduct, hydrogen peroxide, confirmed that catechol was oxidized as a result of applied electricity. Contact mechanics testing further confirmed that the Young’s modulus of the adhesive increased by nearly 4 folds at the interface as a result of oxidative cross-linking, even though the modulus of the bulk of the adhesive was unaffected by applied electricity. The accumulation of hydroxyl ions near the cathode increased the local solution pH, which promoted oxidation-induced cross-linking of catechol and subsequently decreased its adhesive property. Tuning adhesive properties through in situ electrochemical oxidation provides on-demand control over the adhesive, which will potentially add another dimension in designing synthetic mimics of mussel adhesive proteins.


  • Open Access

    Antibacterial Properties of Mussel-Inspired Polydopamine Coatings Prepared by a Simple Two-Step Shaking-Assisted Method

    by Pegah Kord Forooshani, Elizabeth Polega, Kevin Thomson, Saleh Akram Bhuiyan, Rattapol Pinnaratip, Mikhail Trought, Chito Kendrick, Yuesheng Gao, Kathryn A. Perrine, Lei Pan, et al.

    A simple two-step, shaking-assisted polydopamine (PDA) coating technique was used to impart polypropylene (PP) mesh with antimicrobial properties. In this modified method, a relatively large concentration of dopamine (20 mg ml−1) was first used to create a stable PDA primer layer, while the second step utilized a significantly lower concentration of dopamine (2 mg ml−1) to promote the formation and deposition of large aggregates of PDA nanoparticles. Gentle shaking (70 rpm) was employed to increase the deposition of PDA nanoparticle aggregates and the formation of a thicker PDA coating with nano-scaled surface roughness (RMS = 110 nm and Ra = 82 nm). Cyclic voltammetry experiment confirmed that the PDA coating remained redox active, despite extensive oxidative cross-linking. When the PDA-coated mesh was hydrated in phosphate saline buffer (pH 7.4), it was activated to generate 200 μM hydrogen peroxide (H2O2) for over 48 h. The sustained release of low doses of H2O2 was antibacterial against both gram-positive (Staphylococcus epidermidis) and gram-negative (Escherichia coli) bacteria. PDA coating achieved 100% reduction (LRV ~3.15) when incubated against E. coli and 98.9% reduction (LRV ~1.97) against S. epi in 24 h.


  • Multifunctional Biomedical Adhesives

    by Rattapol Pinnaratip, Mohammad Saleh Akram Bhuiyan, Kaylee Meyers, Rupak M. Rajachar, Bruce P. Lee

    Currently available biomedical adhesives are mainly engineered to have one function (i.e., providing mechanical support for the repaired tissue). To improve the performance of existing bioadhesives and broaden their applications in medicine, numerous multifunctional bioadhesives are reported in the literature. These adhesives can be categorized as passive or active by design. Passive multifunctional bioadhesives contain inherent compositions and structural designs that can carry out additional functions without added external influences. These adhesives exhibit new functionalities such as antimicrobial properties, self‐healing abilities, the ability to promote cellular ingrowth, and the ability to be reshaped. Conversely, active multifunctional bioadhesives respond to environmental changes (e.g., pH, temperature, electricity, light, and biomolecule concentration), which initiate a change in the adhesive to release encapsulated drugs or to activate or deactivate the bioadhesive for interfacial binding. This review article highlights recent advances in multifunctional bioadhesives.


  • Analysis and improvement of Si integrated on-chip dipole antennas using high-k dielectric materials for ultra wideband signal transmission

    by Mahmud-Ul-Tarik Chowdhury, Mouinul Islam, Saleh Akram Bhuiyan

    In this paper, a linear on-chip dipole antenna pair on Si substrate is analyzed and simulated to investigate the transmission characteristics using CST MICROWAVE STUDIO. By inserting a 1.4 mm thick diamond layer between substrate and heat sink, the obtained transmission gain of antenna pair of length 4mm with 3mm separation on 10 Ohm-cm Si substrate increases by 12dB at 14GHz and for 1.5mm thick beryllia layer transmission gain increases 12 dB at 14.5 GHz. The effect of the dielectric materials like diamond, AlN, Alumina, beryllia, Taconic CER-10 and Arlon AR 1000thickness, substrate resistivity and the separation of an antenna pair on the transmission gain has been investigated. The results indicate that for highly dielectric materials of low electrical conductivity but high thermal conductivity, the transmission gain increases in real interconnection systems.


  • Microcontroller and operational amplifier based motion sensor

    by Saleh Akram Bhuiyan, H. M. Moshiur Rahman Mondal

    The paper presents a simple design and implementation of a Motion sensor. It enables to detect the movement of any things near the circuit. An Infrared sender and Infrared receiver is used. Infrared transmits a signal when circuit is ON and Infrared receiver receives signal when any things move around the Infrared sender.

  • Profile optimization of dispersion shifted fiber based on optifiber design, simulation and performance analysis

    by Saleh Akram Bhuiyan, H. M. Moshiur Rahman Mondal

    An optimized dispersion shifted fiber with simple and specific fiber profile is introduced. According to the results of dispersion, attenuation, mode field diameter, microbending loss, splice loss for such fibers are presented and compared to the alternate designs. This detailed design and outputs helps an individual to understand the principles of dispersion shifting and profile optimizing.


  • An analytical approach of defining best single mode fiber by analysing fiber performance with subtle core diameter variation

    by Saleh Akram Bhuiyan, H. M. Moshiur Rahman Mondal

    Design of single mode fiber is introduced by maintaining the previous design milestone and valid specifications are taken as input using Optifiber simulator, so performance outputs are nearly accurate. Main tuning parameter is core diameter and whole approach is analytically verified with subtle performance observation. Furthermore, the design model and methodology can be applied to design other modern devices such as dispersion based fibers, multimode and graded index fiber.