Andres Soler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andres Soler has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Eduardo Giraldo
Department of Electrical Engineering, Universidad Tecnológica de Pereira, Pereira, Colombia
7 shared publicationsMarta Molinas
Department of Engineering Cybernetics, Norwegian University of Science and Tech nology, O.S. Bragstads plass 2D, Trondheim, 7034, Norway
7 shared publications- Marta Molinas
Department of Engineering Cybernetics, Norwegian University of Science and Technology, Norway
7 shared publications - Eduardo Giraldo
Research Group in Automatic Control, Electrical Engineering Department, Universidad Tecnológica de Pereira, Pereira 660003, Colombia
5 shared publications - Maximiliano Bueno-Lopez
Universidad Tecnológica de Pereira image/svg+xml
2 shared publications - Pablo Andrés Muñoz Gutiérrez
Universidad del Quindío
2 shared publications
Latest Publications
- Open Access
- 3 September 2024
- Published by Universidad de San Buenaventura in International Journal of Psychological Research
- Vol. 17 (2) , 91-99
EEG-Based Alcohol Detection System for Driver Monitoring
Today, alcohol drinking frequently accompanies socialising as a routine activity in various groups of society. 84.0% of individuals aged 18 and above in the United States have drunk alcohol at some point in their life (National Institute on Alcohol Abuse & US, 2023). Similarly, 81.7% of Norwegians in the age group 16 to 79 have drunk alcohol in 2021 (Bye, 2018). Driving after the consumption of alcohol is a worldwide problem, causing a large number of deaths and injuries a year. This work proposes the first steps towards developing an electroencephalography (EEG)-based alcohol detector conceived with the idea to prevent people from driving under the influence of alcohol. This includes the design of an experimental protocol for EEG data collection, during which participants performed the Flanker task, and their blood alcohol concentration (BAC) was measured. The resulting data set consists of two sessions per participant, both while they are affected and not-affected by alcohol. Statistical analysis of the Flanker task indicated that participants were affected by alcohol and, therefore, their EEG signals were expected to be affected as well. The collected EEG signals were used as input for intra-subject and inter-subject models, both based on the EEGNet architecture. The intra-subject model obtained a mean classification accuracy of 90.7% and the inter-subject model a mean classification accuracy of 62.9%. The result suggest that alcohol can be detected with high accuracy when developing individual models and above the change accuracy when using a general model. Therefore, the work presented here could be used as the first steps towards the development of an EEG-based alcohol detector for drivers.
- 3 September 2024
- Published by Universidad de San Buenaventura in International Journal of Psychological Research
- Vol. 17 (2) , 91-99
Open AccessEEG-Based Alcohol Detection System for Driver Monitoring
Today, alcohol drinking frequently accompanies socialising as a routine activity in various groups of society. 84.0% of individuals aged 18 and above in the United States have drunk alcohol at some point in their life (National Institute on Alcohol Abuse & US, 2023). Similarly, 81.7% of Norwegians in the age group 16 to 79 have drunk alcohol in 2021 (Bye, 2018). Driving after the consumption of alcohol is a worldwide problem, causing a large number of deaths and injuries a year. This work proposes the first steps towards developing an electroencephalography (EEG)-based alcohol detector conceived with the idea to prevent people from driving under the influence of alcohol. This includes the design of an experimental protocol for EEG data collection, during which participants performed the Flanker task, and their blood alcohol concentration (BAC) was measured. The resulting data set consists of two sessions per participant, both while they are affected and not-affected by alcohol. Statistical analysis of the Flanker task indicated that participants were affected by alcohol and, therefore, their EEG signals were expected to be affected as well. The collected EEG signals were used as input for intra-subject and inter-subject models, both based on the EEGNet architecture. The intra-subject model obtained a mean classification accuracy of 90.7% and the inter-subject model a mean classification accuracy of 62.9%. The result suggest that alcohol can be detected with high accuracy when developing individual models and above the change accuracy when using a general model. Therefore, the work presented here could be used as the first steps towards the development of an EEG-based alcohol detector for drivers.
- 27 June 2024
- Published by Springer Nature
- p. 128-143
Impact of Ocular Artifact Removal on EEG-Based Color Classification for Locked-In Syndrome BCI Communication
- 27 June 2024
- Published by Springer Nature
- p. 128-143
Impact of Ocular Artifact Removal on EEG-Based Color Classification for Locked-In Syndrome BCI Communication
- Open Access
- 7 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108722
Newly identified Phonocardiography frequency bands for psychological stress detection with Deep Wavelet Scattering Network
- 7 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108722
Open AccessNewly identified Phonocardiography frequency bands for psychological stress detection with Deep Wavelet Scattering Network
- Open Access
- 4 May 2024
- Published by Springer Nature in Brain Informatics
- Vol. 11 (1) , 1-12
EEG source imaging of hand movement-related areas: an evaluation of the reconstruction and classification accuracy with optimized channels
The hand motor activity can be identified and converted into commands for controlling machines through a brain-computer interface (BCI) system. Electroencephalography (EEG) based BCI systems employ electrodes to measure the electrical brain activity projected at the scalp and discern patterns. However, the volume conduction problem attenuates the electric potential from the brain to the scalp and introduces spatial mixing to the signals. EEG source imaging (ESI) techniques can be applied to alleviate these issues and enhance the spatial segregation of information. Despite this potential solution, the use of ESI has not been extensively applied in BCI systems, largely due to accuracy concerns over reconstruction accuracy when using low-density EEG (ldEEG), which is commonly used in BCIs. To overcome these accuracy issues in low channel counts, recent studies have proposed reducing the number of EEG channels based on optimized channel selection. This work presents an evaluation of the spatial and temporal accuracy of ESI when applying optimized channel selection towards ldEEG number of channels. For this, a simulation study of source activity related to hand movement has been performed using as a starting point an EEG system with 339 channels. The results obtained after optimization show that the activity in the concerned areas can be retrieved with a spatial accuracy of 3.99, 10.69, and 14.29 mm (localization error) when using 32, 16, and 8 channel counts respectively. In addition, the use of optimally selected electrodes has been validated in a motor imagery classification task, obtaining a higher classification performance when using 16 optimally selected channels than 32 typical electrode distributions under 10–10 system, and obtaining higher classification performance when combining ESI methods with the optimal selected channels.
- 4 May 2024
- Published by Springer Nature in Brain Informatics
- Vol. 11 (1) , 1-12
Open AccessEEG source imaging of hand movement-related areas: an evaluation of the reconstruction and classification accuracy with optimized channels
The hand motor activity can be identified and converted into commands for controlling machines through a brain-computer interface (BCI) system. Electroencephalography (EEG) based BCI systems employ electrodes to measure the electrical brain activity projected at the scalp and discern patterns. However, the volume conduction problem attenuates the electric potential from the brain to the scalp and introduces spatial mixing to the signals. EEG source imaging (ESI) techniques can be applied to alleviate these issues and enhance the spatial segregation of information. Despite this potential solution, the use of ESI has not been extensively applied in BCI systems, largely due to accuracy concerns over reconstruction accuracy when using low-density EEG (ldEEG), which is commonly used in BCIs. To overcome these accuracy issues in low channel counts, recent studies have proposed reducing the number of EEG channels based on optimized channel selection. This work presents an evaluation of the spatial and temporal accuracy of ESI when applying optimized channel selection towards ldEEG number of channels. For this, a simulation study of source activity related to hand movement has been performed using as a starting point an EEG system with 339 channels. The results obtained after optimization show that the activity in the concerned areas can be retrieved with a spatial accuracy of 3.99, 10.69, and 14.29 mm (localization error) when using 32, 16, and 8 channel counts respectively. In addition, the use of optimally selected electrodes has been validated in a motor imagery classification task, obtaining a higher classification performance when using 16 optimally selected channels than 32 typical electrode distributions under 10–10 system, and obtaining higher classification performance when combining ESI methods with the optimal selected channels.
- 13 September 2023
- Published by Springer Nature
- p. 432-442
EEG Source Imaging of Hand Movement-Related Areas: An Evaluation of the Reconstruction Accuracy with Optimized Channels
- 13 September 2023
- Published by Springer Nature
- p. 432-442
EEG Source Imaging of Hand Movement-Related Areas: An Evaluation of the Reconstruction Accuracy with Optimized Channels
- Open Access
- 2 July 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-18
Automated methodology for optimal selection of minimum electrode subsets for accurate EEG source estimation based on Genetic Algorithm optimization
High-density Electroencephalography (HD-EEG) has proven to be the EEG montage that estimates the neural activity inside the brain with highest accuracy. Multiple studies have reported the effect of electrode number on source localization for specific sources and specific electrode configurations. The electrodes for these configurations are often manually selected to uniformly cover the entire head, going from 32 to 128 electrodes, but electrode configurations are not often selected according to their contribution to estimation accuracy. In this work, an optimization-based study is proposed to determine the minimum number of electrodes that can be used and to identify the optimal combinations of electrodes that can retain the localization accuracy of HD-EEG reconstructions. This optimization approach incorporates scalp landmark positions of widely used EEG montages. In this way, a systematic search for the minimum electrode subset is performed for single- and multiple-source localization problems. The Non-dominated Sorting Genetic Algorithm II (NSGA-II) combined with source reconstruction methods is used to formulate a multi-objective optimization problem that concurrently minimizes (1) the localization error for each source and (2) the number of required EEG electrodes. The method can be used for evaluating the source localization quality of low-density EEG systems (e.g. consumer-grade wearable EEG). We performed an evaluation over synthetic and real EEG datasets with known ground-truth. The experimental results show that optimal subsets with 6 electrodes can attain an equal or better accuracy than HD-EEG (with more than 200 channels) for a single source case. This happened when reconstructing a particular brain activity in more than 88% of the cases in synthetic signals and 63% in real signals, and in more than 88% and 73% of cases when considering optimal combinations with 8 channels. For a multiple-source case of three sources (only with synthetic signals), it was found that optimized combinations of 8, 12 and 16 electrodes attained an equal or better accuracy than HD-EEG with 231 electrodes in at least 58%, 76%, and 82% of cases respectively. Additionally, for such electrode numbers, lower mean errors and standard deviations than with 231 electrodes were obtained.
- 2 July 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-18
Open AccessAutomated methodology for optimal selection of minimum electrode subsets for accurate EEG source estimation based on Genetic Algorithm optimization
High-density Electroencephalography (HD-EEG) has proven to be the EEG montage that estimates the neural activity inside the brain with highest accuracy. Multiple studies have reported the effect of electrode number on source localization for specific sources and specific electrode configurations. The electrodes for these configurations are often manually selected to uniformly cover the entire head, going from 32 to 128 electrodes, but electrode configurations are not often selected according to their contribution to estimation accuracy. In this work, an optimization-based study is proposed to determine the minimum number of electrodes that can be used and to identify the optimal combinations of electrodes that can retain the localization accuracy of HD-EEG reconstructions. This optimization approach incorporates scalp landmark positions of widely used EEG montages. In this way, a systematic search for the minimum electrode subset is performed for single- and multiple-source localization problems. The Non-dominated Sorting Genetic Algorithm II (NSGA-II) combined with source reconstruction methods is used to formulate a multi-objective optimization problem that concurrently minimizes (1) the localization error for each source and (2) the number of required EEG electrodes. The method can be used for evaluating the source localization quality of low-density EEG systems (e.g. consumer-grade wearable EEG). We performed an evaluation over synthetic and real EEG datasets with known ground-truth. The experimental results show that optimal subsets with 6 electrodes can attain an equal or better accuracy than HD-EEG (with more than 200 channels) for a single source case. This happened when reconstructing a particular brain activity in more than 88% of the cases in synthetic signals and 63% in real signals, and in more than 88% and 73% of cases when considering optimal combinations with 8 channels. For a multiple-source case of three sources (only with synthetic signals), it was found that optimized combinations of 8, 12 and 16 electrodes attained an equal or better accuracy than HD-EEG with 231 electrodes in at least 58%, 76%, and 82% of cases respectively. Additionally, for such electrode numbers, lower mean errors and standard deviations than with 231 electrodes were obtained.
- Open Access
Automatic Sleep Stage Classification with Optimized Selection of EEG Channels
Visual inspection of Polysomnography (PSG) recordings by sleep experts based on established guidelines has been the gold standard in sleep stage classification. This approach is expensive, time consuming and mostly limited to experimental research and clinical cases of major sleep disorders. Various automatic approaches to sleep scoring have been emerging in the past years and are opening the way to a quick computational assessment of sleep architecture that may find its way to the clinics. With the hope to make sleep scoring a fully automated process in the clinics, we report here an ensemble algorithm that aims at not only predicting sleep stages but of doing so with an optimized minimal number of EEG channels. For that, we combine a genetic algorithm based optimization with a classification framework that minimizes the number of channels used by the machine learning algorithm to quantify sleep stages. This resulted in a scoring with an F1 score of 0.793 for the fully automatic model and 0.806 for the model trained on 10 percent of the unseen subject, both with only 3 EEG channels. The ensemble algorithm is based on a combination of extremely randomized trees and MiniRocket classifiers. The algorithm was trained, validated and tested on night sleep PSG data collected from 7 subjects. The novelty of our approach lies on the use of the minimum information needed for automated sleep scoring, based on a systematic search that concurrently selects the optimal-minimum number of EEG channels and the best performing features for the machine learning classifier. The optimization framework presented in this work may enable new designs for sleep scoring devices suited to studies in the comfort of the homes, easily and inexpensively and in this way facilitate experimental and clinical studies in large populations.
Open AccessAutomatic Sleep Stage Classification with Optimized Selection of EEG Channels
Visual inspection of Polysomnography (PSG) recordings by sleep experts based on established guidelines has been the gold standard in sleep stage classification. This approach is expensive, time consuming and mostly limited to experimental research and clinical cases of major sleep disorders. Various automatic approaches to sleep scoring have been emerging in the past years and are opening the way to a quick computational assessment of sleep architecture that may find its way to the clinics. With the hope to make sleep scoring a fully automated process in the clinics, we report here an ensemble algorithm that aims at not only predicting sleep stages but of doing so with an optimized minimal number of EEG channels. For that, we combine a genetic algorithm based optimization with a classification framework that minimizes the number of channels used by the machine learning algorithm to quantify sleep stages. This resulted in a scoring with an F1 score of 0.793 for the fully automatic model and 0.806 for the model trained on 10 percent of the unseen subject, both with only 3 EEG channels. The ensemble algorithm is based on a combination of extremely randomized trees and MiniRocket classifiers. The algorithm was trained, validated and tested on night sleep PSG data collected from 7 subjects. The novelty of our approach lies on the use of the minimum information needed for automated sleep scoring, based on a systematic search that concurrently selects the optimal-minimum number of EEG channels and the best performing features for the machine learning classifier. The optimization framework presented in this work may enable new designs for sleep scoring devices suited to studies in the comfort of the homes, easily and inexpensively and in this way facilitate experimental and clinical studies in large populations.
- Open Access
- 1 January 2022
- Published by INSTICC
- p. 174-183
Relevance-based Channel Selection for EEG Source Reconstruction: An Approach to Identify Low-density Channel Subsets
- 1 January 2022
- Published by INSTICC
- p. 174-183
Open AccessRelevance-based Channel Selection for EEG Source Reconstruction: An Approach to Identify Low-density Channel Subsets
- Open Access
Automated methodology for optimal selection of minimum electrode subsets for accurate EEG source estimation based on Genetic Algorithm optimization
High-density Electroencephalography (HD-EEG) has been proven to be the most accurate option to estimate the neural activity inside the brain. Multiple studies report the effect of electrode number on source localization for specific sources and specific electrode configurations. The electrodes for these configurations have been manually selected to uniformly cover the entire head, going from 32 to 128 electrodes, but electrodes were not selected according to their contribution to accuracy. In this work, an optimization-based study is proposed to determine the minimum number of electrodes and identify optimal combinations of electrodes that can retain the localization accuracy of HD-EEG reconstructions. This optimization approach incorporates scalp landmark positions of widely used EEG montages. In this way, a systematic search for the minimum electrode subset is performed for single and multiple source localization problems. The Non-dominated Sorting Genetic Algorithm II (NSGA-II) combined with source reconstruction methods is used to formulate a multi-objective optimization problem that concurrently minimizes 1) the localization error for each source and 2) the number of required EEG electrodes. The method can be used for evaluating the source localization quality of low-density EEG systems (e.g. consumer-grade wearable EEG). We performed an evaluation over synthetic and real EEG dataset with known ground-truth. The experimental results show that optimal subsets with 6 electrodes can obtain an equal or better accuracy than HD-EEG (with more than 200 channels) for a single source case. This happened when reconstructing a particular brain activity in more than 88% of the cases (in synthetic signals) and 63% (in real signals), and in more than 88% and 73% of the cases when considering optimal combinations with 8 channels. For a multiple-source case of three sources (only with synthetic signals), it was found that optimized combinations of 8, 12 and 16 electrodes attained an equal or better accuracy than HD-EEG with 231 electrodes in at least 58%, 76%, and 82% of the cases respectively. Additionally, for such electrode numbers, a lower mean error and standard deviation than with 231 electrodes were obtained. Highlights: The number of EEG electrodes and their locations can be optimized for reconstructing the brain source activity. Optimally selected EEG electrodes can retain the accuracy of high density montages (256, 128 chs) for brain source estimation, when electrodes are selected according to their contribution to accuracy. With optimization, selected combinations of EEG electrodes will flexibilize the estimation of the source activity.
Open AccessAutomated methodology for optimal selection of minimum electrode subsets for accurate EEG source estimation based on Genetic Algorithm optimization
High-density Electroencephalography (HD-EEG) has been proven to be the most accurate option to estimate the neural activity inside the brain. Multiple studies report the effect of electrode number on source localization for specific sources and specific electrode configurations. The electrodes for these configurations have been manually selected to uniformly cover the entire head, going from 32 to 128 electrodes, but electrodes were not selected according to their contribution to accuracy. In this work, an optimization-based study is proposed to determine the minimum number of electrodes and identify optimal combinations of electrodes that can retain the localization accuracy of HD-EEG reconstructions. This optimization approach incorporates scalp landmark positions of widely used EEG montages. In this way, a systematic search for the minimum electrode subset is performed for single and multiple source localization problems. The Non-dominated Sorting Genetic Algorithm II (NSGA-II) combined with source reconstruction methods is used to formulate a multi-objective optimization problem that concurrently minimizes 1) the localization error for each source and 2) the number of required EEG electrodes. The method can be used for evaluating the source localization quality of low-density EEG systems (e.g. consumer-grade wearable EEG). We performed an evaluation over synthetic and real EEG dataset with known ground-truth. The experimental results show that optimal subsets with 6 electrodes can obtain an equal or better accuracy than HD-EEG (with more than 200 channels) for a single source case. This happened when reconstructing a particular brain activity in more than 88% of the cases (in synthetic signals) and 63% (in real signals), and in more than 88% and 73% of the cases when considering optimal combinations with 8 channels. For a multiple-source case of three sources (only with synthetic signals), it was found that optimized combinations of 8, 12 and 16 electrodes attained an equal or better accuracy than HD-EEG with 231 electrodes in at least 58%, 76%, and 82% of the cases respectively. Additionally, for such electrode numbers, a lower mean error and standard deviation than with 231 electrodes were obtained. Highlights: The number of EEG electrodes and their locations can be optimized for reconstructing the brain source activity. Optimally selected EEG electrodes can retain the accuracy of high density montages (256, 128 chs) for brain source estimation, when electrodes are selected according to their contribution to accuracy. With optimization, selected combinations of EEG electrodes will flexibilize the estimation of the source activity.
- 15 September 2021
- Published by Springer Nature
- p. 277-286
Searching for Unique Neural Descriptors of Primary Colours in EEG Signals: A Classification Study
- 15 September 2021
- Published by Springer Nature
- p. 277-286
Searching for Unique Neural Descriptors of Primary Colours in EEG Signals: A Classification Study