Brandon K. Zimmerman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brandon K. Zimmerman has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Gerard A. Ateshian
Department of Mechanical Engineering, Columbia University , New York, NY 10027
3 shared publications - Xin Lucas Lu
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, United States
3 shared publications Ana L. Elias
Department of Physics and Center for 2‐Dimensional and Layered Materials The Pennsylvania State University 104 Davey Lab University Park PA 16802‐6300 USA
2 shared publicationsBingqing Wei
Department of Mechanical Engineering University of Delaware Newark DE 19716 USA
2 shared publicationsBoris I. Yakobson
Department of Materials Science and NanoEngineering Rice University Houston TX 77005 USA
2 shared publicationsClark T. Hung
Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, NY 10027, USA; Department of Orthopedic Surgery, Columbia University, 622 West 168th Street PH 11 - Center, New York, NY 10032, USA
2 shared publications
Latest Publications
- Open Access
- 15 October 2026
- Published by Elsevier in Materialia
- Vol. 50
Relative density effects on deformation mechanisms and failure modes in gyroid lattices
- 15 October 2026
- Published by Elsevier in Materialia
- Vol. 50
Open AccessRelative density effects on deformation mechanisms and failure modes in gyroid lattices
- Open Access
- 16 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Investigating property-porosity relationships for micro-architected lattice structures
Micro-architected structures are increasingly valued for their light weight and tunable mechanical properties; this class of material includes sheet structures like the Schöen gyroid and beam lattices like the octet. For design purposes, it is critical to understand how to tune the relative density (RD) to obtain desired mechanical properties. This study investigates the mechanical response of Ti-6Al-4V gyroid structures, spanning a broad range of RDs (0.03–0.90), unit cell sizes (1–4 cm), and sheet thicknesses (0.2–7.8 mm). Results demonstrate that the classical Gibson-Ashby power law scaling between RD and modulus and yield stress does not adequately capture the response over a wide range of RDs, nor does it extrapolate correctly to the fully dense solid. Analytical models, in concert with experimental results and high-fidelity finite element calculations, show that the deviation from Gibson-Ashby reflects a transition from structure-dominated to material-dominated behavior. Distinctions are drawn between scaling relationships and property-porosity models, and an analytical model is proposed to better capture the evolution of mechanical properties with RD. These observations are mirrored in other architected topologies, like the octet, and highlight the importance of understanding the relationship between mechanical properties and geometry for design purposes.
- 16 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessInvestigating property-porosity relationships for micro-architected lattice structures
Micro-architected structures are increasingly valued for their light weight and tunable mechanical properties; this class of material includes sheet structures like the Schöen gyroid and beam lattices like the octet. For design purposes, it is critical to understand how to tune the relative density (RD) to obtain desired mechanical properties. This study investigates the mechanical response of Ti-6Al-4V gyroid structures, spanning a broad range of RDs (0.03–0.90), unit cell sizes (1–4 cm), and sheet thicknesses (0.2–7.8 mm). Results demonstrate that the classical Gibson-Ashby power law scaling between RD and modulus and yield stress does not adequately capture the response over a wide range of RDs, nor does it extrapolate correctly to the fully dense solid. Analytical models, in concert with experimental results and high-fidelity finite element calculations, show that the deviation from Gibson-Ashby reflects a transition from structure-dominated to material-dominated behavior. Distinctions are drawn between scaling relationships and property-porosity models, and an analytical model is proposed to better capture the evolution of mechanical properties with RD. These observations are mirrored in other architected topologies, like the octet, and highlight the importance of understanding the relationship between mechanical properties and geometry for design purposes.
- 2 December 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (3) , 707-718
Toward Lesion-specific Stenting Strategies: A Computational Framework to Validate the Deployment of Balloon-expandable Stents
Purpose Clinical failure rates associated with in-stent restenosis are difficult to predict and manage, particularly at the patient-specific level. Studies have linked biomechanical factors to focal disease development and progression, suggesting that physics-based simulations using finite element (FE) approaches hold potential to mitigate stent failure rates. However, insufficient validation to assess the accuracy of model predictions limit model credibility for clinical translation. Herein, we established a computational framework to validate vascular stent deployment by integrating robust simulation and rigorous experimental approaches. Methods Experimental testing characterized the transient deformation of a commercially available balloon-expandable stent system, and high-resolution image data were post-processed to create a representative FE model. Non-linear material behaviors and physical boundary conditions were varied to create mixed-fidelity models that assessed the effects of modeling assumptions on stent deformation metrics. Results Qualitative comparisons of stent deployment stages showed that high-fidelity FE models captured the characteristic burst opening of the stent edges, followed by the central stent region. Quantitative metrics determined from pressure–diameter curves showed strong agreement, with root mean square error and concordance correlation coefficient values for the proximal, central, and distal diameters ranging from 0.31 mm and 0.96, respectively (lowest fidelity) to 0.21 mm and 0.99 (highest fidelity). Analysis of higher-order metrics (i.e., dog-boning, foreshortening) further demonstrated strong agreement. Conclusion This framework successfully established a validation plan for vascular stent deployment, analyzed errors in model development, and demonstrated the utility of quantitative assessments, potentially improving the translatability of in silico tools and reducing device failure rates.
- 2 December 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (3) , 707-718
Toward Lesion-specific Stenting Strategies: A Computational Framework to Validate the Deployment of Balloon-expandable Stents
Purpose Clinical failure rates associated with in-stent restenosis are difficult to predict and manage, particularly at the patient-specific level. Studies have linked biomechanical factors to focal disease development and progression, suggesting that physics-based simulations using finite element (FE) approaches hold potential to mitigate stent failure rates. However, insufficient validation to assess the accuracy of model predictions limit model credibility for clinical translation. Herein, we established a computational framework to validate vascular stent deployment by integrating robust simulation and rigorous experimental approaches. Methods Experimental testing characterized the transient deformation of a commercially available balloon-expandable stent system, and high-resolution image data were post-processed to create a representative FE model. Non-linear material behaviors and physical boundary conditions were varied to create mixed-fidelity models that assessed the effects of modeling assumptions on stent deformation metrics. Results Qualitative comparisons of stent deployment stages showed that high-fidelity FE models captured the characteristic burst opening of the stent edges, followed by the central stent region. Quantitative metrics determined from pressure–diameter curves showed strong agreement, with root mean square error and concordance correlation coefficient values for the proximal, central, and distal diameters ranging from 0.31 mm and 0.96, respectively (lowest fidelity) to 0.21 mm and 0.99 (highest fidelity). Analysis of higher-order metrics (i.e., dog-boning, foreshortening) further demonstrated strong agreement. Conclusion This framework successfully established a validation plan for vascular stent deployment, analyzed errors in model development, and demonstrated the utility of quantitative assessments, potentially improving the translatability of in silico tools and reducing device failure rates.
- Open Access
- 2 June 2025
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 78
Growth-induced Donnan exclusion influences swelling kinetics in highly charged dynamic polymerization hydrogels
- 2 June 2025
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 78
Open AccessGrowth-induced Donnan exclusion influences swelling kinetics in highly charged dynamic polymerization hydrogels
- 27 September 2024
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 195
Solid face sheets enable lattice metamaterials to withstand high-amplitude impulsive loading without yielding
- 27 September 2024
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 195
Solid face sheets enable lattice metamaterials to withstand high-amplitude impulsive loading without yielding
- Open Access
- 21 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Self-Similarity in the Formation of Explosive Hot Spots
High explosive detonation starts with formation of hot spots at microstructural defects but has eluded "full physics" atomistic modeling treatment at micron length scales. To this end, we develop an image distinguishability analysis to summarize multimicron all-atom MD simulations of hot spot formation for pore sizes between 10 and 300 nm to show that all but the smallest hot spots exhibit self-similar size scaling. Through grain-scale modeling we link this behavior to the material’s rate-insensitive mechanical strength. Our results bolster confidence in insights from small-scale MD simulations and provide means to quantitatively compare complex processes at diverse length scales.
- 21 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSelf-Similarity in the Formation of Explosive Hot Spots
High explosive detonation starts with formation of hot spots at microstructural defects but has eluded "full physics" atomistic modeling treatment at micron length scales. To this end, we develop an image distinguishability analysis to summarize multimicron all-atom MD simulations of hot spot formation for pore sizes between 10 and 300 nm to show that all but the smallest hot spots exhibit self-similar size scaling. Through grain-scale modeling we link this behavior to the material’s rate-insensitive mechanical strength. Our results bolster confidence in insights from small-scale MD simulations and provide means to quantitatively compare complex processes at diverse length scales.
- 13 October 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 163, 248-258
Superficial zone chondrocytes can get compacted under physiological loading: A multiscale finite element analysis
- 13 October 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 163, 248-258
Superficial zone chondrocytes can get compacted under physiological loading: A multiscale finite element analysis
- 14 October 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 12 (565)
Tissue engineered autologous cartilage-bone grafts for temporomandibular joint regeneration
Bioengineered autologous cartilage-bone ramus-condyle grafts enable temporomandibular joint regeneration in a clinically sized porcine model.
- 14 October 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 12 (565)
Tissue engineered autologous cartilage-bone grafts for temporomandibular joint regeneration
Bioengineered autologous cartilage-bone ramus-condyle grafts enable temporomandibular joint regeneration in a clinically sized porcine model.