Divya Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Divya Gupta has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Sudhansu Chokroverty
JFK Neuroscience Institute, Hackensack Meridian Health - JFK Medical Center, 65 James Street, Edison, NJ, 08818, USA
6 shared publicationsPeter G. Polos
JFK Neuroscience Institute, Hackensack Meridian Health-JFK Medical Center, Edison, NJ 08818, USA
4 shared publicationsSushanth Bhat
JFK Neuroscience Institute, Hackensack Meridian Health - JFK Medical Center, 65 James Street, Edison, NJ, 08818, USA
4 shared publications- Sushanth Bhat
JFK New Jersey Neuroscience Institute
4 shared publications Vincent A. DeBari
Seton Hall University, South Orange, NJ, USA
4 shared publicationsHinesh Upadhyay
Memorial Sloan Kettering Cancer Center, New York, NY, USA
2 shared publications
Latest Publications
- Open Access
- 23 May 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (3)
A pilot study to assess a novel screening questionnaire for central sleep apnea in patients undergoing overnight diagnostic polysomnography
Purpose: A novel central sleep apnea (CSA) screening questionnaire, SCOUTS-BAG-HARMS (SBH), was developed and assessed with polysomnography (PSG)-confirmed “any CSA”, defined as a central apnea index (CAI) ≥ 5 per hour. Unlike the STOP-BANG questionnaire, which screens for obstructive sleep apnea (OSA), SBH incorporates CSA-specific questions in three sections (SCOUTS), including silent apneas, demographics (BAG), including body mass index, and comorbidities (HARMS), including heart failure. Methods: In this pilot study, patients undergoing a PSG at our sleep lab between January and June 2023 were administered both the STOP-BANG and the SBH questionnaires. Questionnaire scores were compared to the CAI on in-lab PSG. Subset analysis assessed whether specific questions or sections of the SBH questionnaire have significant correlation with the finding of CAI ≥ 5 per hour. Results: Neither the STOP-BANG questionnaire nor the SBH questionnaire total score correlated linearly with the severity of CAI on PSG, but the SBH score ≥ 6 out of 20 correlated with the finding of CSA. On subset analysis, the HARMS section of SBH correlated with the finding of CSA on PSG. Adding the HARMS question responses to the total score on STOP-BANG also correlated with the finding of CSA. Conclusion: Since most patients with CSA also have some degree of obstructive type respiratory events, adding HARMS questions to the widely used STOP-BANG screening questionnaire for OSA may help identify patients at risk for CSA in the general population. This, in turn, would lead to prompt diagnostic testing and treatment for CSA.
- 23 May 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (3)
Open AccessA pilot study to assess a novel screening questionnaire for central sleep apnea in patients undergoing overnight diagnostic polysomnography
Purpose: A novel central sleep apnea (CSA) screening questionnaire, SCOUTS-BAG-HARMS (SBH), was developed and assessed with polysomnography (PSG)-confirmed “any CSA”, defined as a central apnea index (CAI) ≥ 5 per hour. Unlike the STOP-BANG questionnaire, which screens for obstructive sleep apnea (OSA), SBH incorporates CSA-specific questions in three sections (SCOUTS), including silent apneas, demographics (BAG), including body mass index, and comorbidities (HARMS), including heart failure. Methods: In this pilot study, patients undergoing a PSG at our sleep lab between January and June 2023 were administered both the STOP-BANG and the SBH questionnaires. Questionnaire scores were compared to the CAI on in-lab PSG. Subset analysis assessed whether specific questions or sections of the SBH questionnaire have significant correlation with the finding of CAI ≥ 5 per hour. Results: Neither the STOP-BANG questionnaire nor the SBH questionnaire total score correlated linearly with the severity of CAI on PSG, but the SBH score ≥ 6 out of 20 correlated with the finding of CSA. On subset analysis, the HARMS section of SBH correlated with the finding of CSA on PSG. Adding the HARMS question responses to the total score on STOP-BANG also correlated with the finding of CSA. Conclusion: Since most patients with CSA also have some degree of obstructive type respiratory events, adding HARMS questions to the widely used STOP-BANG screening questionnaire for OSA may help identify patients at risk for CSA in the general population. This, in turn, would lead to prompt diagnostic testing and treatment for CSA.
- 1 November 2018
- Published by Elsevier in Sleep Medicine
- Vol. 51, 115-117
Co-occurrence of respiratory event-related and spontaneous rhythmic movements in REM sleep
- 1 November 2018
- Published by Elsevier in Sleep Medicine
- Vol. 51, 115-117
Co-occurrence of respiratory event-related and spontaneous rhythmic movements in REM sleep
- Open Access
- 1 January 2016
- Published by Medknow in Annals of Thoracic Medicine
- Vol. 11 (2) , 151-4
The therapeutic dilemma of vagus nerve stimulator-induced sleep disordered breathing
Intermittent vagus nerve stimulation (VNS) can reduce the frequency of seizures in patients with refractory epilepsy, but can affect respiration in sleep. Untreated obstructive sleep apnea (OSA) can worsen seizure frequency. Unfortunately, OSA and VNS-induced sleep disordered breathing (SDB) may occur in the same patient, leading to a therapeutic dilemma. We report a pediatric patient in whom OSA improved after tonsillectomy, but coexistent VNS-induced SDB persisted. With decrease in VNS output current, patient's SDB improved, but seizure activity exacerbated, which required a return to the original settings. Continuous positive airway pressure titration was attempted, which showed only a partial improvement in apnea–hypopnea index. This case illustrates the need for clinicians to balance seizure control and SDB in patients with VNS.
- 1 January 2016
- Published by Medknow in Annals of Thoracic Medicine
- Vol. 11 (2) , 151-4
Open AccessThe therapeutic dilemma of vagus nerve stimulator-induced sleep disordered breathing
Intermittent vagus nerve stimulation (VNS) can reduce the frequency of seizures in patients with refractory epilepsy, but can affect respiration in sleep. Untreated obstructive sleep apnea (OSA) can worsen seizure frequency. Unfortunately, OSA and VNS-induced sleep disordered breathing (SDB) may occur in the same patient, leading to a therapeutic dilemma. We report a pediatric patient in whom OSA improved after tonsillectomy, but coexistent VNS-induced SDB persisted. With decrease in VNS output current, patient's SDB improved, but seizure activity exacerbated, which required a return to the original settings. Continuous positive airway pressure titration was attempted, which showed only a partial improvement in apnea–hypopnea index. This case illustrates the need for clinicians to balance seizure control and SDB in patients with VNS.
- 21 August 2015
- Published by Wiley in Journal of Adolescence
- Vol. 44 (1) , 232-244
The impact of Sleep Time‐Related Information and Communication Technology (STRICT) on sleep patterns and daytime functioning in American adolescents
This cross‐sectional study explored the extent and impact of mobile device‐based Sleep Time‐Related Information and Communication Technology (STRICT) use among American adolescents (N = 3139, 49.3% female, mean age = 13.3 years). Nearly 62% used STRICT after bedtime, 56.7% texted/tweeted/messaged in bed, and 20.8% awoke to texts. STRICT use was associated with insomnia, daytime sleepiness, eveningness, academic underperformance, later bedtimes and shorter sleep duration. Moderation analysis demonstrated that the association between STRICT use and insomnia increased with age, the association between STRICT use and daytime sleepiness decreased with age, and the association between STRICT use and shorter sleep duration decreased with age and was stronger in girls. Insomnia and daytime sleepiness partially mediated the relationship between STRICT use and academic underperformance. Our results illustrate the adverse interactions between adolescent STRICT use and sleep, with deleterious effects on daytime functioning. These worrisome findings suggest that placing reasonable limitations on adolescent STRICT use may be appropriate.
- 21 August 2015
- Published by Wiley in Journal of Adolescence
- Vol. 44 (1) , 232-244
The impact of Sleep Time‐Related Information and Communication Technology (STRICT) on sleep patterns and daytime functioning in American adolescents
This cross‐sectional study explored the extent and impact of mobile device‐based Sleep Time‐Related Information and Communication Technology (STRICT) use among American adolescents (N = 3139, 49.3% female, mean age = 13.3 years). Nearly 62% used STRICT after bedtime, 56.7% texted/tweeted/messaged in bed, and 20.8% awoke to texts. STRICT use was associated with insomnia, daytime sleepiness, eveningness, academic underperformance, later bedtimes and shorter sleep duration. Moderation analysis demonstrated that the association between STRICT use and insomnia increased with age, the association between STRICT use and daytime sleepiness decreased with age, and the association between STRICT use and shorter sleep duration decreased with age and was stronger in girls. Insomnia and daytime sleepiness partially mediated the relationship between STRICT use and academic underperformance. Our results illustrate the adverse interactions between adolescent STRICT use and sleep, with deleterious effects on daytime functioning. These worrisome findings suggest that placing reasonable limitations on adolescent STRICT use may be appropriate.
- 15 July 2015
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 11 (7) , 709-715
Is There a Clinical Role For Smartphone Sleep Apps? Comparison of Sleep Cycle Detection by a Smartphone Application to Polysomnography
Several inexpensive, readily available smartphone apps that claim to monitor sleep are popular among patients. However, their accuracy is unknown, which limits their widespread clinical use. We therefore conducted this study to evaluate the validity of parameters reported by one such app, the Sleep Time app (Azumio, Inc., Palo Alto, CA, USA) for iPhones. Twenty volunteers with no previously diagnosed sleep disorders underwent in-laboratory polysomnography (PSG) while simultaneously using the app. Parameters reported by the app were then compared to those obtained by PSG. In addition, an epoch-by-epoch analysis was performed by dividing the PSG and app graph into 15-min epochs. There was no correlation between PSG and app sleep efficiency (r = -0.127, p = 0.592), light sleep percentage (r = 0.024, p = 0.921), deep sleep percentage (r = 0.181, p = 0.444) or sleep latency (rs = 0.384, p = 0.094). The app slightly and nonsignificantly overestimated sleep efficiency by 0.12% (95% confidence interval [CI] -4.9 to 5.1%, p = 0.962), significantly underestimated light sleep by 27.9% (95% CI 19.4-36.4%, p < 0.0001), significantly overestimated deep sleep by 11.1% (CI 4.7-17.4%, p = 0.008) and significantly overestimated sleep latency by 15.6 min (CI 9.7-21.6, p < 0.0001). Epochwise comparison showed low overall accuracy (45.9%) due to poor interstage discrimination, but high accuracy in sleep-wake detection (85.9%). The app had high sensitivity but poor specificity in detecting sleep (89.9% and 50%, respectively). Our study shows that the absolute parameters and sleep staging reported by the Sleep Time app (Azumio, Inc.) for iPhones correlate poorly with PSG. Further studies comparing app sleep-wake detection to actigraphy may help elucidate its potential clinical utility. A commentary on this article appears in this issue on page 695.
- 15 July 2015
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 11 (7) , 709-715
Is There a Clinical Role For Smartphone Sleep Apps? Comparison of Sleep Cycle Detection by a Smartphone Application to Polysomnography
Several inexpensive, readily available smartphone apps that claim to monitor sleep are popular among patients. However, their accuracy is unknown, which limits their widespread clinical use. We therefore conducted this study to evaluate the validity of parameters reported by one such app, the Sleep Time app (Azumio, Inc., Palo Alto, CA, USA) for iPhones. Twenty volunteers with no previously diagnosed sleep disorders underwent in-laboratory polysomnography (PSG) while simultaneously using the app. Parameters reported by the app were then compared to those obtained by PSG. In addition, an epoch-by-epoch analysis was performed by dividing the PSG and app graph into 15-min epochs. There was no correlation between PSG and app sleep efficiency (r = -0.127, p = 0.592), light sleep percentage (r = 0.024, p = 0.921), deep sleep percentage (r = 0.181, p = 0.444) or sleep latency (rs = 0.384, p = 0.094). The app slightly and nonsignificantly overestimated sleep efficiency by 0.12% (95% confidence interval [CI] -4.9 to 5.1%, p = 0.962), significantly underestimated light sleep by 27.9% (95% CI 19.4-36.4%, p < 0.0001), significantly overestimated deep sleep by 11.1% (CI 4.7-17.4%, p = 0.008) and significantly overestimated sleep latency by 15.6 min (CI 9.7-21.6, p < 0.0001). Epochwise comparison showed low overall accuracy (45.9%) due to poor interstage discrimination, but high accuracy in sleep-wake detection (85.9%). The app had high sensitivity but poor specificity in detecting sleep (89.9% and 50%, respectively). Our study shows that the absolute parameters and sleep staging reported by the Sleep Time app (Azumio, Inc.) for iPhones correlate poorly with PSG. Further studies comparing app sleep-wake detection to actigraphy may help elucidate its potential clinical utility. A commentary on this article appears in this issue on page 695.
- Open Access
- 15 August 2014
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 10 (8) , 887-892
The Efficacy of a Chinstrap in Treating Sleep Disordered Breathing and Snoring
A previously published case report suggested that a chinstrap alone might improve obstructive sleep apnea (OSA). We conducted this study to determine whether a chinstrap was a feasible alternative to continuous positive airway pressure (CPAP) in patients with OSA. 26 adult patients with OSA (apnea-hypopnea index [AHI] > 5/h on diagnostic polysomnogram [PSG]) underwent a modified split-night PSG, using only a chinstrap for the first 2 hours of sleep, followed by CPAP titration for the remainder of the night. Improvements in AHI, arterial oxygen saturation (SpO2), and snoring with chinstrap use were compared to results with optimal CPAP pressures. There was no significant difference between the diagnostic PSG and the chinstrap portion of the split-night PSG in the following parameters: general AHI (median [IQR] 16.0/h [9.7-26.0] vs. 25.9/h [10.7-42.7]), SpO2 nadir (84.0% [80.5-87.5] vs. 87.0 [84.0-88.5]), AHI in REM sleep (26.7/h [16.8-43.7] vs. 42.4/h [21.3-57.7]), AHI in supine sleep (24.9/h [11.9-51.5] vs. 29.8/h [11.7-55.5]), snoring index (253.2/h [147.5-353.1] vs. 180.0/h [9.8-393.3]) or subjective snoring scale (3.0 [0.8-3.0] vs. 2.5 [0.4-3.0]). The AHI and SpO2 nadir in the 13 patients with mild OSA also did not improve with chinstrap use (9.6/h [8.1-12.2] vs. 10.6/h [6.8-35.4] and 87.0% [83.0-90.0] vs. 88.0% [87.0-89.0]). All these parameters showed significant improvement with optimal CPAP titration (p < 0.05). A chinstrap alone is not an effective treatment for OSA. It does not improve sleep disordered breathing, even in mild OSA, nor does it improve the AHI in REM sleep or supine sleep. It is also ineffective in improving snoring.
- 15 August 2014
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 10 (8) , 887-892
Open AccessThe Efficacy of a Chinstrap in Treating Sleep Disordered Breathing and Snoring
A previously published case report suggested that a chinstrap alone might improve obstructive sleep apnea (OSA). We conducted this study to determine whether a chinstrap was a feasible alternative to continuous positive airway pressure (CPAP) in patients with OSA. 26 adult patients with OSA (apnea-hypopnea index [AHI] > 5/h on diagnostic polysomnogram [PSG]) underwent a modified split-night PSG, using only a chinstrap for the first 2 hours of sleep, followed by CPAP titration for the remainder of the night. Improvements in AHI, arterial oxygen saturation (SpO2), and snoring with chinstrap use were compared to results with optimal CPAP pressures. There was no significant difference between the diagnostic PSG and the chinstrap portion of the split-night PSG in the following parameters: general AHI (median [IQR] 16.0/h [9.7-26.0] vs. 25.9/h [10.7-42.7]), SpO2 nadir (84.0% [80.5-87.5] vs. 87.0 [84.0-88.5]), AHI in REM sleep (26.7/h [16.8-43.7] vs. 42.4/h [21.3-57.7]), AHI in supine sleep (24.9/h [11.9-51.5] vs. 29.8/h [11.7-55.5]), snoring index (253.2/h [147.5-353.1] vs. 180.0/h [9.8-393.3]) or subjective snoring scale (3.0 [0.8-3.0] vs. 2.5 [0.4-3.0]). The AHI and SpO2 nadir in the 13 patients with mild OSA also did not improve with chinstrap use (9.6/h [8.1-12.2] vs. 10.6/h [6.8-35.4] and 87.0% [83.0-90.0] vs. 88.0% [87.0-89.0]). All these parameters showed significant improvement with optimal CPAP titration (p < 0.05). A chinstrap alone is not an effective treatment for OSA. It does not improve sleep disordered breathing, even in mild OSA, nor does it improve the AHI in REM sleep or supine sleep. It is also ineffective in improving snoring.
- 1 August 2013
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 30 (4) , 403-410
Intensified Hypnic Jerks
Purpose: To analyze the nature and propagation of muscle bursts in patients presenting with intensified hypnic jerks and sleep onset insomnia. Methods: We obtained polymyographic recordings from cranially and spinally innervated muscles during polysomnographic study in 10 subjects presenting with repeated jerking movements at sleep onset, anxiety and sleep onset insomnia. One subject also had daytime polymyography during relaxed wakefulness and drowsiness as well as back-averaging of the EEG preceding the muscle bursts. Results: We observed 4 patterns of muscle propagation: synchronous and symmetrical patterned muscle bursts between the two sides and agonist-antagonist muscles similar to those noted in audiogenic startle reflex, reticular reflex myoclonus, dystonic myoclonus, and pyramidal myoclonus with rostrocaudal propagation of muscle bursts. Conclusion: Hypnic jerks are physiological phenomena which may be accentuated and repeated and may be of several physiological subtypes.
- 1 August 2013
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 30 (4) , 403-410
Intensified Hypnic Jerks
Purpose: To analyze the nature and propagation of muscle bursts in patients presenting with intensified hypnic jerks and sleep onset insomnia. Methods: We obtained polymyographic recordings from cranially and spinally innervated muscles during polysomnographic study in 10 subjects presenting with repeated jerking movements at sleep onset, anxiety and sleep onset insomnia. One subject also had daytime polymyography during relaxed wakefulness and drowsiness as well as back-averaging of the EEG preceding the muscle bursts. Results: We observed 4 patterns of muscle propagation: synchronous and symmetrical patterned muscle bursts between the two sides and agonist-antagonist muscles similar to those noted in audiogenic startle reflex, reticular reflex myoclonus, dystonic myoclonus, and pyramidal myoclonus with rostrocaudal propagation of muscle bursts. Conclusion: Hypnic jerks are physiological phenomena which may be accentuated and repeated and may be of several physiological subtypes.
- 1 February 2013
- Published by Elsevier in Sleep Medicine
- Vol. 14 (2) , 220-221
The effect of lateral head position on sleep disordered breathing: A case series
- 1 February 2013
- Published by Elsevier in Sleep Medicine
- Vol. 14 (2) , 220-221
The effect of lateral head position on sleep disordered breathing: A case series