Priyo Heru Adiwibowo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Priyo Heru Adiwibowo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- A. Grummy Wailanduw
Universitas Negeri Surabaya
2 shared publications - Aris Ansori
Universitas Negeri Surabaya
1 shared publication Arrahmad Dwi Budiarto
Universitas Negeri Surabaya,Dept. Electrical Engineering,Surabaya,Indonesia
1 shared publicationHariyati
Dept. Economic, Universitas Negeri Surabaya, Surabaya, Indonesia
1 shared publication- Indra Herlamba Siregar
Universitas Negeri Surabaya image/svg+xml
1 shared publication Khoirul Fadli
Universitas Negeri Surabaya,Dept. Electrical Engineering,Surabaya,Indonesia
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Elsevier in Results in Engineering
- Vol. 31
Performance enhancement of side-by-side hydrokinetic savonius turbines with central and side triangular plates configurations
- 2 June 2026
- Published by Elsevier in Results in Engineering
- Vol. 31
Open AccessPerformance enhancement of side-by-side hydrokinetic savonius turbines with central and side triangular plates configurations
- Open Access
- 21 May 2026
- Published by Lembaga Penelitian dan Pengabdian Masyarakat Universitas Jambi in Jurnal Ilmiah Ilmu Terapan Universitas Jambi
- Vol. 10 (3) , 1630-1640
INTEGRATION OF RENEWABLE ENERGY OF SOLAR PV AND UTILITY PLN GRID FOR THE OPTIMAL CHARGING OF ELECTRIC VEHICLES THE RESIDENTIAL SCALE
This study proposes and evaluates an off-grid hybrid electric vehicle (EV) charging system that integrates a 5 kWp solar photovoltaic (PV) array, a 5.5 kW PLN grid connection, and a 12 kWh battery energy storage system controlled by an automatic transfer switch (ATS). The system is designed to maximize solar PV utilization while minimizing dependence on the PLN grid during peak demand periods, thereby reducing carbon emissions, electricity consumption, and charging costs. Experimental testing was conducted using two EV types: a Viar NX electric motorcycle (1.338 kWh battery capacity) and a Wuling Air EV Long Range electric car (26.7 kWh battery capacity). Both vehicles were charged from 30% to 100% state of charge under different operating conditions. Energy generation from the PV system, battery storage performance, and PLN grid contribution were monitored using kWh meters and data loggers. Performance evaluation considered energy production, electricity cost savings, and economic feasibility. Results indicate that the PV system generated an average of 12.38 kWh/day for EV charging. During the dry season, monthly PV generation ranged from 368.40 to 383.78 kWh, while production declined to approximately 286.75 kWh during the rainy season because of reduced solar irradiation. The battery storage and PLN grid effectively compensated for low PV output, ensuring uninterrupted charging. Solar PV supplied approximately 48.06% of the total EV charging energy demand, with charging performance strongly influenced by daytime charging schedules and favorable weather conditions. These findings confirm the technical and economic feasibility of residential-scale hybrid solar PV-based EV charging systems.
- 21 May 2026
- Published by Lembaga Penelitian dan Pengabdian Masyarakat Universitas Jambi in Jurnal Ilmiah Ilmu Terapan Universitas Jambi
- Vol. 10 (3) , 1630-1640
Open AccessINTEGRATION OF RENEWABLE ENERGY OF SOLAR PV AND UTILITY PLN GRID FOR THE OPTIMAL CHARGING OF ELECTRIC VEHICLES THE RESIDENTIAL SCALE
This study proposes and evaluates an off-grid hybrid electric vehicle (EV) charging system that integrates a 5 kWp solar photovoltaic (PV) array, a 5.5 kW PLN grid connection, and a 12 kWh battery energy storage system controlled by an automatic transfer switch (ATS). The system is designed to maximize solar PV utilization while minimizing dependence on the PLN grid during peak demand periods, thereby reducing carbon emissions, electricity consumption, and charging costs. Experimental testing was conducted using two EV types: a Viar NX electric motorcycle (1.338 kWh battery capacity) and a Wuling Air EV Long Range electric car (26.7 kWh battery capacity). Both vehicles were charged from 30% to 100% state of charge under different operating conditions. Energy generation from the PV system, battery storage performance, and PLN grid contribution were monitored using kWh meters and data loggers. Performance evaluation considered energy production, electricity cost savings, and economic feasibility. Results indicate that the PV system generated an average of 12.38 kWh/day for EV charging. During the dry season, monthly PV generation ranged from 368.40 to 383.78 kWh, while production declined to approximately 286.75 kWh during the rainy season because of reduced solar irradiation. The battery storage and PLN grid effectively compensated for low PV output, ensuring uninterrupted charging. Solar PV supplied approximately 48.06% of the total EV charging energy demand, with charging performance strongly influenced by daytime charging schedules and favorable weather conditions. These findings confirm the technical and economic feasibility of residential-scale hybrid solar PV-based EV charging systems.
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 124-127
Long Short-Term Memory Decomposition Model for Forecasting Solar Irradiance Photovoltaic Household Scale on Grid
A proposed study using the development of the Long Short Term Memory Decomposition hybrid method for maximalization forecasting of solar irradiance (SI) based on meteorology data using a development decomposition and long short-term memory model. This combination modeling is a development decomposition model and an LSTM model. The combination development decomposition long short-term memory (DD-LSTM) modified hybrid model is designed to predict solar irradiance photovoltaic household scale on grid 1 hour ahead based on weather data for solar irradiance household scale on grid photovoltaic station. The proposed research of this hybrid model is taken into calculation based on meteorology data. The method development decomposition is a process of training and testing to the Long Short Term Memory model. In the error statistical calculation index of the DD-LSTM model, the mean absolute percentage error (MAPE) is 1 %. The hybrid combination model forecasting is then compared to actual data, development decomposition, and training results indicate that the DD-LSTM model explained in the study can calculate hourly solar irradiance with optimal accuracy.
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 124-127
Long Short-Term Memory Decomposition Model for Forecasting Solar Irradiance Photovoltaic Household Scale on Grid
A proposed study using the development of the Long Short Term Memory Decomposition hybrid method for maximalization forecasting of solar irradiance (SI) based on meteorology data using a development decomposition and long short-term memory model. This combination modeling is a development decomposition model and an LSTM model. The combination development decomposition long short-term memory (DD-LSTM) modified hybrid model is designed to predict solar irradiance photovoltaic household scale on grid 1 hour ahead based on weather data for solar irradiance household scale on grid photovoltaic station. The proposed research of this hybrid model is taken into calculation based on meteorology data. The method development decomposition is a process of training and testing to the Long Short Term Memory model. In the error statistical calculation index of the DD-LSTM model, the mean absolute percentage error (MAPE) is 1 %. The hybrid combination model forecasting is then compared to actual data, development decomposition, and training results indicate that the DD-LSTM model explained in the study can calculate hourly solar irradiance with optimal accuracy.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 020025
Force coefficient characteristics on a four circular cylinders in an in-line square configuration near a plane wall at “small gap”
This paper presents the calculation of the force coefficients of four circular cylinders in equispaced configurations through their pressure distribution measurements. The pressure distributions on every cylinder surface and the plane wall were measured for a gap-diameter ratio of G/D = 0.2 and various spacing-diameter ratio of L/D = 2.0, 2.7, 3.0 and 4.0, in a uniform flow at a Reynolds Number of 5.3 × 104. The results indicated that the spacing-diameter ratio (L/D) gave the important influence on the drag and lift coefficients of the cylinders. Where, the coefficient of drag is decreasing, when the amount of L/D is increasing, especially on the upstream cylinders. The lift coefficient on the upper-downstream cylinders has significant value more than others cylinder at a small spacing ratio.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 020025
Force coefficient characteristics on a four circular cylinders in an in-line square configuration near a plane wall at “small gap”
This paper presents the calculation of the force coefficients of four circular cylinders in equispaced configurations through their pressure distribution measurements. The pressure distributions on every cylinder surface and the plane wall were measured for a gap-diameter ratio of G/D = 0.2 and various spacing-diameter ratio of L/D = 2.0, 2.7, 3.0 and 4.0, in a uniform flow at a Reynolds Number of 5.3 × 104. The results indicated that the spacing-diameter ratio (L/D) gave the important influence on the drag and lift coefficients of the cylinders. Where, the coefficient of drag is decreasing, when the amount of L/D is increasing, especially on the upstream cylinders. The lift coefficient on the upper-downstream cylinders has significant value more than others cylinder at a small spacing ratio.