Hideo Asada
Hideo Asada has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Masanori Shukuya
7 shared publicationsHitoshi Takeda
Dept. of Architecture, Faculty of Science and Tech., Tokyo University of Science
3 shared publicationsToshiya Iwamatsu
3 shared publicationsMiwako Tokura
2 shared publicationsYasuhiro Miki
2 shared publications- Angela Simone
International Centre for Indoor Environment and Energy (ICIEE), Department of Civil Engineering, Technical University of Denmark (DTU), Building 402, Kongens Lyngby, 2800, Denmark
1 shared publication
Latest Publications
- 1 January 2012
- Published by Inderscience Publishers in International Journal of Exergy
- Vol. 11 (4) , 493
Development of human-body exergy balance model for a better understanding of thermal comfort in the built environment
This paper briefly describes the human-body exergy balance equation developed so far applying a variety of formulae derived from the fundamentals of thermodynamics, namely the concepts of wet/dry exergy associated with moist air and liquid water, warm/cool exergy transferred by radiation and convection. A couple of numerical examples of the whole human-body exergy balance are given and discussed in relations to mean radiant temperature, room air temperature, air velocity, and outdoor environmental temperature. We have found so far that it is very important to control the amount of thermal radiant exergy in room space both in winter and in summer.
- 1 January 2012
- Published by Inderscience Publishers in International Journal of Exergy
- Vol. 11 (4) , 493
Development of human-body exergy balance model for a better understanding of thermal comfort in the built environment
This paper briefly describes the human-body exergy balance equation developed so far applying a variety of formulae derived from the fundamentals of thermodynamics, namely the concepts of wet/dry exergy associated with moist air and liquid water, warm/cool exergy transferred by radiation and convection. A couple of numerical examples of the whole human-body exergy balance are given and discussed in relations to mean radiant temperature, room air temperature, air velocity, and outdoor environmental temperature. We have found so far that it is very important to control the amount of thermal radiant exergy in room space both in winter and in summer.
- 1 January 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (1) , 1-9
A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation
- 1 January 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (1) , 1-9
A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation
- 1 January 2010
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 75 (653) , 585-594
A STUDY ON THE RELATIONSHIP BETWEEN THERMAL COGNITION OF ROOM SPACE CONTROLLED BY HIGH-TEMPERATURE RADIANT COOLING PANEL COMBINED WITH NATURAL VENTILATION AND HUMAN-BODY EXERGY BALANCE
- 1 January 2010
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 75 (653) , 585-594
A STUDY ON THE RELATIONSHIP BETWEEN THERMAL COGNITION OF ROOM SPACE CONTROLLED BY HIGH-TEMPERATURE RADIANT COOLING PANEL COMBINED WITH NATURAL VENTILATION AND HUMAN-BODY EXERGY BALANCE
- 1 January 2008
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 73 (629) , 857-864
EXPERIMENT ON SUBJECTIVE EVALUATION OF LUMINOUS ENVIRONMENT OF A LIVING ROOM WITH VARIOUS ARRANGEMENTS OF SMALL ELECTRIC LIGHTS WITH COMPACT SELF-BALLASTED FLUORESCENT LAMP AND DIFFERENT LIGHT SOURCE COLOR IN DAYTIME AND NIGHTTIME
- 1 January 2008
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 73 (629) , 857-864
EXPERIMENT ON SUBJECTIVE EVALUATION OF LUMINOUS ENVIRONMENT OF A LIVING ROOM WITH VARIOUS ARRANGEMENTS OF SMALL ELECTRIC LIGHTS WITH COMPACT SELF-BALLASTED FLUORESCENT LAMP AND DIFFERENT LIGHT SOURCE COLOR IN DAYTIME AND NIGHTTIME
- Open Access
- 1 January 2006
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 71 (603) , 9-16
PROPOSAL OF DISTRIBUTED MULTIPLE-LIGHT ARRANGEMENT USING SMALL HIGH-EFFICIENCY LAMPS AND EVALUATION EXPERIMENT IN THE LIVING AND DINING ROOMS : Research on the improvement of lighting quality and energy conservation by distributed multiple-light arrangement in the residential building Part 1
- 1 January 2006
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 71 (603) , 9-16
Open AccessPROPOSAL OF DISTRIBUTED MULTIPLE-LIGHT ARRANGEMENT USING SMALL HIGH-EFFICIENCY LAMPS AND EVALUATION EXPERIMENT IN THE LIVING AND DINING ROOMS : Research on the improvement of lighting quality and energy conservation by distributed multiple-light arrangement in the residential building Part 1
- 1 August 2004
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 25 (3) , 197-209
Exergy analysis of a low temperature radiant heating system
The purpose of this study is to gain insight into the process of heating a room with a low-temperature radiant heating system and solar energy, considering energy conversion and heat transfer steps in the building (where heat is required), in the incident solar radiation (which supplies part of the heat required) and in the heating system (which provides for the additional heating needs, by using electricity from a gas-fired power plant to drive a heat pump). We applied a theoretical framework developed by Shukuya et al., to a dynamic simulation model and did numerical calculations for a room with an exterior wall, with and without a south-facing window, during a heating season in the Netherlands. The exergy analysis allows direct comparison between different energy types (e.g., heat, electricity, fuel) on a common basis, and the concept of exergy consumption is useful for expressing how and where energy is dispersed in the course of energy conversion and heat transfer steps. The results show that exergy consumption in the room (demand side) is relatively small compared to the supply side (fuel burned at the power plant and the sun reaching the ground and facade). The calculations also show that the total amount of exergy consumed during the heating season can be larger than the total amount of exergy supplied during the same period, as a result of heat storage in the building mass, and of changes in the outdoor temperature between the moment of heat storage and heat release.
- 1 August 2004
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 25 (3) , 197-209
Exergy analysis of a low temperature radiant heating system
The purpose of this study is to gain insight into the process of heating a room with a low-temperature radiant heating system and solar energy, considering energy conversion and heat transfer steps in the building (where heat is required), in the incident solar radiation (which supplies part of the heat required) and in the heating system (which provides for the additional heating needs, by using electricity from a gas-fired power plant to drive a heat pump). We applied a theoretical framework developed by Shukuya et al., to a dynamic simulation model and did numerical calculations for a room with an exterior wall, with and without a south-facing window, during a heating season in the Netherlands. The exergy analysis allows direct comparison between different energy types (e.g., heat, electricity, fuel) on a common basis, and the concept of exergy consumption is useful for expressing how and where energy is dispersed in the course of energy conversion and heat transfer steps. The results show that exergy consumption in the room (demand side) is relatively small compared to the supply side (fuel burned at the power plant and the sun reaching the ground and facade). The calculations also show that the total amount of exergy consumed during the heating season can be larger than the total amount of exergy supplied during the same period, as a result of heat storage in the building mass, and of changes in the outdoor temperature between the moment of heat storage and heat release.
- Open Access
- 1 January 2003
- Published by Architectural Institute of Japan in Journal of Architecture and Planning (Transactions of AIJ)
- Vol. 68 (563) , 25-31
MEASUREMENT OF THERMAL ENVIRONMENT AND EXERGY ANALYSIS ON CEILING RADIANT COOLING SYSTEM USING GROUND WATER
- 1 January 2003
- Published by Architectural Institute of Japan in Journal of Architecture and Planning (Transactions of AIJ)
- Vol. 68 (563) , 25-31
Open AccessMEASUREMENT OF THERMAL ENVIRONMENT AND EXERGY ANALYSIS ON CEILING RADIANT COOLING SYSTEM USING GROUND WATER
- 1 January 2003
- Published by Springer Nature in MRS Proceedings
- Vol. 785
Optical Constants of Vanadium Dioxide Films and Design of a Solar Energy Control Window
We determined the optical constants of a vanadium dioxide (VO2) thermochromic film deposited on glass substrate by ellipsometry in wavelength range from 380 nm to 1700 nm. The optical constants were employed to design the optimal stacked thin film structure for smart windows which control the solar radiation and heat transmission from the viewpoint of high luminous transmission.
- 1 January 2003
- Published by Springer Nature in MRS Proceedings
- Vol. 785
Optical Constants of Vanadium Dioxide Films and Design of a Solar Energy Control Window
We determined the optical constants of a vanadium dioxide (VO2) thermochromic film deposited on glass substrate by ellipsometry in wavelength range from 380 nm to 1700 nm. The optical constants were employed to design the optimal stacked thin film structure for smart windows which control the solar radiation and heat transmission from the viewpoint of high luminous transmission.
- Open Access
- 1 January 1998
- Published by Illuminating Engineering Society of Japan in Journal of the Illuminating Engineering Institute of Japan
- Vol. 82 (9) , 739-742
Evaluation of Lighting System in the Term of Exergy
- 1 January 1998
- Published by Illuminating Engineering Society of Japan in Journal of the Illuminating Engineering Institute of Japan
- Vol. 82 (9) , 739-742
Open AccessEvaluation of Lighting System in the Term of Exergy