Rieta N. Aben
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rieta N. Aben has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Harry Onoriode Eyituoyo
Georgia Arrhythmia Consultants Macon Georgia USA
2 shared publications Nkechi C. Arinze
Georgia Arrhythmia Consultants Macon Georgia USA
2 shared publicationsDat Phat Vu
Departmnet of Internal Medicine, Mercer University School of Medicine, Macon, USA
1 shared publication- Erskine A. James
Advanced Heart Failure Center, Cardiovascular Intensive Care Unit, Medical Center, Navicent Health, Macon, USA
1 shared publication - Felix Sogade
Georgia Arrhythmia Consultants Macon Georgia USA
1 shared publication - Omolade O. Sogade
Section of Surgical Oncology, Department of Surgery, Washington University in St. Louis School of Medicine, St. Louis, MO https://twitter.com/ladesogade
1 shared publication
Latest Publications
- Open Access
- 13 June 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (8) , 1365-1370
Feasibility study for echocardiography‐guided lead insertion for permanent cardiac implantable electronic devices
Background: Permanent cardiac implantable electronic devices (CIEDs) are traditionally implanted with the assistance of fluoroscopy. While clinically effective, this technique exposes both patients and providers to radiation which is associated with adverse health effects and represents an occupational hazard. In this study, we investigate the safety and feasibility of permanent CIED placement under the guidance of transthoracic echocardiography (TTE). There is also increasing interest in use of non‐fluoroscopic options for noninvasive cardiac electrophysiologic procedures.Methods: Fifteen patients consecutively consented for initial implant of CIEDs, specifically dual chamber pacemakers (DCPM) and dual chamber implantable cardioverter defibrillators (DCICDs). Patients were excluded if they had previous implants, abandoned leads, or anatomic anomalies including congenital and known persistent left superior vena cava (PLSVC). We used TTE to guide and implant atrial and ventricular leads.Results: Eleven patients received DCPMs and four patients received DCICDs. The procedure duration was 49.3 min for DCICD and 52.3 min for DCPM, p = .807. The average number of right atrial lead attempts was 1.6 for DCPMs and 1.8 for DCICD, p = .860. The average number of right ventricular lead attempts for DCPMs was 2.2 and 1.0 attempt for DCICDs, p = .044. There were no complications at 90‐day follow‐up.Conclusion: We demonstrate the feasibility of TTE‐guided DCPM/DCICD implantation without use of fluoroscopy. We present this method as a safe alternative for permanent CIED placement that may reduce risk of radiation exposure and cost while maintaining safety and efficacy. No operators wore lead aprons during the procedure.
- 13 June 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (8) , 1365-1370
Open AccessFeasibility study for echocardiography‐guided lead insertion for permanent cardiac implantable electronic devices
Background: Permanent cardiac implantable electronic devices (CIEDs) are traditionally implanted with the assistance of fluoroscopy. While clinically effective, this technique exposes both patients and providers to radiation which is associated with adverse health effects and represents an occupational hazard. In this study, we investigate the safety and feasibility of permanent CIED placement under the guidance of transthoracic echocardiography (TTE). There is also increasing interest in use of non‐fluoroscopic options for noninvasive cardiac electrophysiologic procedures.Methods: Fifteen patients consecutively consented for initial implant of CIEDs, specifically dual chamber pacemakers (DCPM) and dual chamber implantable cardioverter defibrillators (DCICDs). Patients were excluded if they had previous implants, abandoned leads, or anatomic anomalies including congenital and known persistent left superior vena cava (PLSVC). We used TTE to guide and implant atrial and ventricular leads.Results: Eleven patients received DCPMs and four patients received DCICDs. The procedure duration was 49.3 min for DCICD and 52.3 min for DCPM, p = .807. The average number of right atrial lead attempts was 1.6 for DCPMs and 1.8 for DCICD, p = .860. The average number of right ventricular lead attempts for DCPMs was 2.2 and 1.0 attempt for DCICDs, p = .044. There were no complications at 90‐day follow‐up.Conclusion: We demonstrate the feasibility of TTE‐guided DCPM/DCICD implantation without use of fluoroscopy. We present this method as a safe alternative for permanent CIED placement that may reduce risk of radiation exposure and cost while maintaining safety and efficacy. No operators wore lead aprons during the procedure.
- Open Access
- 20 June 2020
- Published by International Scientific Information, Inc. in American Journal of Case Reports
- Vol. 21, e923711-e923711-5
Ventricular Fibrillation 7 Years After Left Ventricular Assist Device Implantation
BACKGROUND Congestive heart failure (CHF) affects over 23 million individuals worldwide and over 5.8 million individuals in the United States. Left ventricular assist device (LVAD) implantation is used as both a bridging and destination therapy for patients with advanced CHF. LVADs are reported to cause ventricular arrhythmias. Ventricular tachycardia and ventricular fibrillation (VF) are common fatal arrhythmias in patients with severe CHF if left untreated. We report a case in which a patient with an LVAD without an implantable cardioverter device (ICD) developed VF with non-classical symptoms with an unknown duration prior to defibrillation. CASE REPORT A 74-year old man was brought to the hospital via Emergency Medical Services (EMS) with a 1-day history of altered mental status, somnolence, and slurred speech. His past medical history was significant for CHF with LVAD Heart Mate II. An initial electrocardiogram (ECG) done by EMS was abnormal but was presumed to be an artifact secondary to LVAD. A 12-lead ECG done in the Emergency Center revealed VF. He required electrical defibrillation. Due to ongoing multiple organ failure, he was admitted to the Intensive Care Unit (ICU) for further care. CONCLUSIONS In the management of VF, the time to defibrillation is of paramount importance. LVAD patients could be in VF and present with non-specific symptoms. EMS personnel should be aware of this, as it can appear to be an artifact on ECG.
- 20 June 2020
- Published by International Scientific Information, Inc. in American Journal of Case Reports
- Vol. 21, e923711-e923711-5
Open AccessVentricular Fibrillation 7 Years After Left Ventricular Assist Device Implantation
BACKGROUND Congestive heart failure (CHF) affects over 23 million individuals worldwide and over 5.8 million individuals in the United States. Left ventricular assist device (LVAD) implantation is used as both a bridging and destination therapy for patients with advanced CHF. LVADs are reported to cause ventricular arrhythmias. Ventricular tachycardia and ventricular fibrillation (VF) are common fatal arrhythmias in patients with severe CHF if left untreated. We report a case in which a patient with an LVAD without an implantable cardioverter device (ICD) developed VF with non-classical symptoms with an unknown duration prior to defibrillation. CASE REPORT A 74-year old man was brought to the hospital via Emergency Medical Services (EMS) with a 1-day history of altered mental status, somnolence, and slurred speech. His past medical history was significant for CHF with LVAD Heart Mate II. An initial electrocardiogram (ECG) done by EMS was abnormal but was presumed to be an artifact secondary to LVAD. A 12-lead ECG done in the Emergency Center revealed VF. He required electrical defibrillation. Due to ongoing multiple organ failure, he was admitted to the Intensive Care Unit (ICU) for further care. CONCLUSIONS In the management of VF, the time to defibrillation is of paramount importance. LVAD patients could be in VF and present with non-specific symptoms. EMS personnel should be aware of this, as it can appear to be an artifact on ECG.