Pablo Garcia Rivera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pablo Garcia Rivera has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Peter J. Adams
19 shared publications- Ioannis Kioutsioukis
Department of Physics, University of Patras, Patras, Greece
15 shared publications Brian T. Dinkelacker
12 shared publications- Ksakousti Skyllakou
Institute of Chemical Engineering Sciences (FORTH/ICE-HT), 26504, Patras, Greece
11 shared publications Spyros N. Pandis
11 shared publications- Spyros N. Pandis
Institute of Chemical Engineering Sciences, ICE-HT/FORTH, Patras, 265 04, Greece
9 shared publications
Latest Publications
- Open Access
- 30 October 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 364
Bias corrections for species- and source-resolved PM2.5 chemical transport model simulations using a geographically weighted regression
- 30 October 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 364
Open AccessBias corrections for species- and source-resolved PM2.5 chemical transport model simulations using a geographically weighted regression
- 10 November 2023
- Published by Elsevier in Atmospheric Environment
- Vol. 316
Predicted and observed changes in summertime biogenic and total organic aerosol in the southeast United States from 2001 to 2010
- 10 November 2023
- Published by Elsevier in Atmospheric Environment
- Vol. 316
Predicted and observed changes in summertime biogenic and total organic aerosol in the southeast United States from 2001 to 2010
- 19 July 2023
- Published by Elsevier in Atmospheric Environment
- Vol. 310
High-resolution downscaling of source resolved PM2.5 predictions using machine learning models
- 19 July 2023
- Published by Elsevier in Atmospheric Environment
- Vol. 310
High-resolution downscaling of source resolved PM2.5 predictions using machine learning models
- Open Access
- 13 December 2022
- Published by Copernicus GmbH in Geoscientific Model Development
- Vol. 15 (23) , 8899-8912
Evaluation of high-resolution predictions of fine particulate matter and its composition in an urban area using PMCAMx-v2.0
Accurately predicting urban PM2.5 concentrations and composition has proved challenging in the past, partially due to the resolution limitations of computationally intensive chemical transport models (CTMs). Increasing the resolution of PM2.5 predictions is desired to support emissions control policy development and address issues related to environmental justice. A nested grid approach using the CTM PMCAMx-v2.0 was used to predict PM2.5 at increasing resolutions of 36 km × 36 km, 12 km × 12 km, 4 km × 4 km, and 1 km × 1 km for a domain largely consisting of Allegheny County and the city of Pittsburgh in southwestern Pennsylvania, US, during February and July 2017. Performance of the model in reproducing PM2.5 concentrations and composition was evaluated at the finest scale using measurements from regulatory sites as well as a network of low-cost monitors. Novel surrogates were developed to allocate emissions from cooking and on-road traffic sources to the 1 km × 1 km resolution grid. Total PM2.5 mass is reproduced well by the model during the winter period with low fractional error (0.3) and fractional bias (+0.05) when compared to regulatory measurements. Comparison with speciated measurements during this period identified small underpredictions of PM2.5 sulfate, elemental carbon (EC), and organic aerosol (OA) offset by a larger overprediction of PM2.5 nitrate. In the summer period, total PM2.5 mass is underpredicted due to a large underprediction of OA (bias = −1.9 µg m−3, fractional bias = −0.41). In the winter period, the model performs well in reproducing the variability between urban measurements and rural measurements of local pollutants such as EC and OA. This effect is less consistent in the summer period due to a larger fraction of long-range-transported OA. Comparison with total PM2.5 concentration measurements from low-cost sensors showed improvements in performance with increasing resolution. Inconsistencies in PM2.5 nitrate predictions in both periods are believed to be due to errors in partitioning between PM2.5 and PM10 modes and motivate improvements to the treatment of dust particles within the model. The underprediction of summer OA would likely be improved by updates to biogenic secondary organic aerosol (SOA) chemistry within the model, which would result in an increase of long-range transport SOA seen in the inner modeling domain. These improvements are obvious topics for future work towards model improvement. Comparison with regulatory monitors showed that increasing resolution from 36 to 1 km improved both fractional error and fractional bias in both modeling periods. Improvements at all types of measurement locations indicated an improved ability of the model to reproduce urban–rural PM2.5 gradients at higher resolutions.
- 13 December 2022
- Published by Copernicus GmbH in Geoscientific Model Development
- Vol. 15 (23) , 8899-8912
Open AccessEvaluation of high-resolution predictions of fine particulate matter and its composition in an urban area using PMCAMx-v2.0
Accurately predicting urban PM2.5 concentrations and composition has proved challenging in the past, partially due to the resolution limitations of computationally intensive chemical transport models (CTMs). Increasing the resolution of PM2.5 predictions is desired to support emissions control policy development and address issues related to environmental justice. A nested grid approach using the CTM PMCAMx-v2.0 was used to predict PM2.5 at increasing resolutions of 36 km × 36 km, 12 km × 12 km, 4 km × 4 km, and 1 km × 1 km for a domain largely consisting of Allegheny County and the city of Pittsburgh in southwestern Pennsylvania, US, during February and July 2017. Performance of the model in reproducing PM2.5 concentrations and composition was evaluated at the finest scale using measurements from regulatory sites as well as a network of low-cost monitors. Novel surrogates were developed to allocate emissions from cooking and on-road traffic sources to the 1 km × 1 km resolution grid. Total PM2.5 mass is reproduced well by the model during the winter period with low fractional error (0.3) and fractional bias (+0.05) when compared to regulatory measurements. Comparison with speciated measurements during this period identified small underpredictions of PM2.5 sulfate, elemental carbon (EC), and organic aerosol (OA) offset by a larger overprediction of PM2.5 nitrate. In the summer period, total PM2.5 mass is underpredicted due to a large underprediction of OA (bias = −1.9 µg m−3, fractional bias = −0.41). In the winter period, the model performs well in reproducing the variability between urban measurements and rural measurements of local pollutants such as EC and OA. This effect is less consistent in the summer period due to a larger fraction of long-range-transported OA. Comparison with total PM2.5 concentration measurements from low-cost sensors showed improvements in performance with increasing resolution. Inconsistencies in PM2.5 nitrate predictions in both periods are believed to be due to errors in partitioning between PM2.5 and PM10 modes and motivate improvements to the treatment of dust particles within the model. The underprediction of summer OA would likely be improved by updates to biogenic secondary organic aerosol (SOA) chemistry within the model, which would result in an increase of long-range transport SOA seen in the inner modeling domain. These improvements are obvious topics for future work towards model improvement. Comparison with regulatory monitors showed that increasing resolution from 36 to 1 km improved both fractional error and fractional bias in both modeling periods. Improvements at all types of measurement locations indicated an improved ability of the model to reproduce urban–rural PM2.5 gradients at higher resolutions.
- Open Access
- 19 September 2022
- Published by Copernicus GmbH
Supplementary material to "Predicted and Observed Changes in Summertime Biogenic and Total Organic Aerosol in the Southeast United States from 2001 to 2010"
- 19 September 2022
- Published by Copernicus GmbH
Open AccessSupplementary material to "Predicted and Observed Changes in Summertime Biogenic and Total Organic Aerosol in the Southeast United States from 2001 to 2010"
- Open Access
- 19 September 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-30
Predicted and Observed Changes in Summertime Biogenic and Total Organic Aerosol in the Southeast United States from 2001 to 2010
Biogenic secondary organic aerosol (bSOA) is a major component of atmospheric particulate matter (PM2.5) in the southeast United States especially during the summer, when emissions of biogenic volatile organic compound (VOCs) are high and emissions from anthropogenic sources enhance the formation of secondary particulate matter. We evaluate the performance of PM2.5 organic aerosol predictions by a chemical transport model (PMCAMx) in response to significant changes in anthropogenic emissions during the summers of 2001 and 2010. Average predicted bSOA concentrations in the southeast US did not change appreciably from the summer of 2001 to the summer of 2010, while the anthropogenic SOA decreased by 45 %. As a result, the biogenic fraction of total OA increased from 0.46 in 2001 to 0.63 in 2010. Partitioning effects due to reduced anthropogenic OA from 2001 resulted in 0.4 µg m-3 less biogenic OA on average in the southeast US in the summer of 2010. This was offset by biogenic SOA increases due to higher biogenic vapor emissions in the warmer 2010 summer. Little noticeable difference was observed in OA prediction performance in the southeast US between the two summer simulation periods. The fractional error of OA predictions remained practically the same (0.41 and 0.44 at CSN sites and 0.40 to 0.41 at IMPROVE sites in the summers of 2001 and 2010 respectively). The fractional bias of OA predictions increased from 0.10 to 0.22 at CSN sites and decreased from 0 to -0.09 at IMPROVE sites between the two periods. Removing the NOx-dependence of SOA formation yields resulted in higher fractional error and fractional bias at both CSN and IMPROVE sites in both summer periods, demonstrating the efficacy of the current formulation of SOA yields. Our analysis suggests that the changes in biogenic OA in this forested relatively polluted region appear to be dominated by the partitioning effects and the NOx effects on SOA yields.
- 19 September 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-30
Open AccessPredicted and Observed Changes in Summertime Biogenic and Total Organic Aerosol in the Southeast United States from 2001 to 2010
Biogenic secondary organic aerosol (bSOA) is a major component of atmospheric particulate matter (PM2.5) in the southeast United States especially during the summer, when emissions of biogenic volatile organic compound (VOCs) are high and emissions from anthropogenic sources enhance the formation of secondary particulate matter. We evaluate the performance of PM2.5 organic aerosol predictions by a chemical transport model (PMCAMx) in response to significant changes in anthropogenic emissions during the summers of 2001 and 2010. Average predicted bSOA concentrations in the southeast US did not change appreciably from the summer of 2001 to the summer of 2010, while the anthropogenic SOA decreased by 45 %. As a result, the biogenic fraction of total OA increased from 0.46 in 2001 to 0.63 in 2010. Partitioning effects due to reduced anthropogenic OA from 2001 resulted in 0.4 µg m-3 less biogenic OA on average in the southeast US in the summer of 2010. This was offset by biogenic SOA increases due to higher biogenic vapor emissions in the warmer 2010 summer. Little noticeable difference was observed in OA prediction performance in the southeast US between the two summer simulation periods. The fractional error of OA predictions remained practically the same (0.41 and 0.44 at CSN sites and 0.40 to 0.41 at IMPROVE sites in the summers of 2001 and 2010 respectively). The fractional bias of OA predictions increased from 0.10 to 0.22 at CSN sites and decreased from 0 to -0.09 at IMPROVE sites between the two periods. Removing the NOx-dependence of SOA formation yields resulted in higher fractional error and fractional bias at both CSN and IMPROVE sites in both summer periods, demonstrating the efficacy of the current formulation of SOA yields. Our analysis suggests that the changes in biogenic OA in this forested relatively polluted region appear to be dominated by the partitioning effects and the NOx effects on SOA yields.
- Open Access
- 19 July 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-31
Evaluation of high-resolution predictions of fine particulate matter and its composition in an urban area using PMCAMx-v2.0
Accurately predicting urban PM2.5 concentrations and composition has proved challenging in the past, partially due to the resolution limitations of computationally intensive chemical transport models (CTMs). Increasing the resolution of PM2.5 predictions is highly desired to better inform air quality and emissions controls policies that protect public health, and also to address issues related to environmental justice. A nested grid approach using the CTM PMCAMx-v2.0 was used to predict PM2.5 at 36 × 36 km, 12 × 12 km, 4 × 4 km, and 1 × 1 km resolution for a domain largely consisting of Allegheny County and the city of Pittsburgh in southwestern Pennsylvania, US during February and July 2017. Performance of the model in reproducing PM2.5 concentrations and composition was evaluated at the finest scale using measurements from regulatory sites as well as a network of low-cost monitors. Total PM2.5 mass is reproduced well by the model during the winter period with low fractional error (0.3) and fractional bias (+0.05) when compared to regulatory measurements. Comparison with speciated measurements during this period identified small underpredictions of PM2.5 sulfate, elemental carbon (EC), and organic aerosol (OA) offset by a larger overprediction of PM2.5 nitrate (bias = +1.4 µg m-3, fractional bias = +0.81). In the summer period, total PM2.5 mass is underpredicted with fractional bias of -0.39. Here, PM2.5 nitrate is overpredicted again with a large fractional bias (+0.7) but significantly lower magnitude (+0.4 µg m-3). Underpredictions in PM2.5 sulfate and EC contribute to the negative prediction bias of total PM2.5 (-0.4 µg m-3 and -0.2 µg m-3, respectively), however the largest underprediction is seen for summer OA (bias = -1.9 µg m-3, fractional bias = -0.41). In the winter period, the model performs well reproducing the variability between urban measurements and rural measurements of local pollutants such as EC and OA. This effect is also captured well in the summer for EC, although the OA performance here is less consistent because much more of this OA is secondary and transported from outside of the inner modeling domain. Comparison with total PM2.5 concentration measurements from low-cost sensors yielded similar results with slightly higher overpredictions seen in the winter (fractional bias = +0.24) and lower underpredictions seen in the summer (fractional bias = -0.27). Inconsistencies in PM2.5 nitrate predictions in both periods are believed to be due to errors in partitioning between PM2.5 and PM10 modes and motivate improvements to the treatment of dust particles within the model. The underprediction of summer OA would likely be improved by updates to biogenic SOA chemistry within the model, which would result in an increase of long-range transport SOA seen in the inner modeling domain. These improvements are obvious topics for future work towards model improvement. Comparison with regulatory monitors showed that increasing resolution from 36 × 36 km to 1 × 1 km improved both fractional error and fractional bias by 0.04 in February 2017. In July 2017, fractional error decreased by 0.05 and fractional bias improved by 0.07 with increasing resolution. Improvements at all types of measurement locations indicated an improved ability of the model to reproduce urban-rural PM2.5 gradients at higher resolutions.
- 19 July 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-31
Open AccessEvaluation of high-resolution predictions of fine particulate matter and its composition in an urban area using PMCAMx-v2.0
Accurately predicting urban PM2.5 concentrations and composition has proved challenging in the past, partially due to the resolution limitations of computationally intensive chemical transport models (CTMs). Increasing the resolution of PM2.5 predictions is highly desired to better inform air quality and emissions controls policies that protect public health, and also to address issues related to environmental justice. A nested grid approach using the CTM PMCAMx-v2.0 was used to predict PM2.5 at 36 × 36 km, 12 × 12 km, 4 × 4 km, and 1 × 1 km resolution for a domain largely consisting of Allegheny County and the city of Pittsburgh in southwestern Pennsylvania, US during February and July 2017. Performance of the model in reproducing PM2.5 concentrations and composition was evaluated at the finest scale using measurements from regulatory sites as well as a network of low-cost monitors. Total PM2.5 mass is reproduced well by the model during the winter period with low fractional error (0.3) and fractional bias (+0.05) when compared to regulatory measurements. Comparison with speciated measurements during this period identified small underpredictions of PM2.5 sulfate, elemental carbon (EC), and organic aerosol (OA) offset by a larger overprediction of PM2.5 nitrate (bias = +1.4 µg m-3, fractional bias = +0.81). In the summer period, total PM2.5 mass is underpredicted with fractional bias of -0.39. Here, PM2.5 nitrate is overpredicted again with a large fractional bias (+0.7) but significantly lower magnitude (+0.4 µg m-3). Underpredictions in PM2.5 sulfate and EC contribute to the negative prediction bias of total PM2.5 (-0.4 µg m-3 and -0.2 µg m-3, respectively), however the largest underprediction is seen for summer OA (bias = -1.9 µg m-3, fractional bias = -0.41). In the winter period, the model performs well reproducing the variability between urban measurements and rural measurements of local pollutants such as EC and OA. This effect is also captured well in the summer for EC, although the OA performance here is less consistent because much more of this OA is secondary and transported from outside of the inner modeling domain. Comparison with total PM2.5 concentration measurements from low-cost sensors yielded similar results with slightly higher overpredictions seen in the winter (fractional bias = +0.24) and lower underpredictions seen in the summer (fractional bias = -0.27). Inconsistencies in PM2.5 nitrate predictions in both periods are believed to be due to errors in partitioning between PM2.5 and PM10 modes and motivate improvements to the treatment of dust particles within the model. The underprediction of summer OA would likely be improved by updates to biogenic SOA chemistry within the model, which would result in an increase of long-range transport SOA seen in the inner modeling domain. These improvements are obvious topics for future work towards model improvement. Comparison with regulatory monitors showed that increasing resolution from 36 × 36 km to 1 × 1 km improved both fractional error and fractional bias by 0.04 in February 2017. In July 2017, fractional error decreased by 0.05 and fractional bias improved by 0.07 with increasing resolution. Improvements at all types of measurement locations indicated an improved ability of the model to reproduce urban-rural PM2.5 gradients at higher resolutions.
- Open Access
- 11 February 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (3) , 2011-2027
Source-resolved variability of fine particulate matter and human exposure in an urban area
Increasing the resolution of chemical transport model (CTM) predictions in urban areas is important to capture sharp spatial gradients in atmospheric pollutant concentrations and better inform air quality and emissions controls policies that protect public health. The chemical transport model PMCAMx (Particulate Matter Comprehensive Air quality Model with Extensions) was used to assess the impact of increasing model resolution on the ability to predict the source-resolved variability and population exposure to PM2.5 at 36×36, 12×12, 4×4, and 1×1 km resolutions over the city of Pittsburgh during typical winter and summer periods (February and July 2017). At the coarse resolution, county-level differences can be observed, while increasing the resolution to 12×12 km resolves the urban–rural gradient. Increasing resolution to 4×4 km resolves large stationary sources such as power plants, and the 1×1 km resolution reveals intra-urban variations and individual roadways within the simulation domain. Regional pollutants that exhibit low spatial variability such as PM2.5 nitrate show modest changes when increasing the resolution beyond 12×12 km. Predominantly local pollutants such as elemental carbon and primary organic aerosol have gradients that can only be resolved at the 1×1 km scale. Contributions from some local sources are enhanced by weighting the average contribution from each source by the population in each grid cell. The average population-weighted PM2.5 concentration does not change significantly with resolution, suggesting that extremely high resolution PM2.5 predictions may not be necessary for effective urban epidemiological analysis at the county level.
- 11 February 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (3) , 2011-2027
Open AccessSource-resolved variability of fine particulate matter and human exposure in an urban area
Increasing the resolution of chemical transport model (CTM) predictions in urban areas is important to capture sharp spatial gradients in atmospheric pollutant concentrations and better inform air quality and emissions controls policies that protect public health. The chemical transport model PMCAMx (Particulate Matter Comprehensive Air quality Model with Extensions) was used to assess the impact of increasing model resolution on the ability to predict the source-resolved variability and population exposure to PM2.5 at 36×36, 12×12, 4×4, and 1×1 km resolutions over the city of Pittsburgh during typical winter and summer periods (February and July 2017). At the coarse resolution, county-level differences can be observed, while increasing the resolution to 12×12 km resolves the urban–rural gradient. Increasing resolution to 4×4 km resolves large stationary sources such as power plants, and the 1×1 km resolution reveals intra-urban variations and individual roadways within the simulation domain. Regional pollutants that exhibit low spatial variability such as PM2.5 nitrate show modest changes when increasing the resolution beyond 12×12 km. Predominantly local pollutants such as elemental carbon and primary organic aerosol have gradients that can only be resolved at the 1×1 km scale. Contributions from some local sources are enhanced by weighting the average contribution from each source by the population in each grid cell. The average population-weighted PM2.5 concentration does not change significantly with resolution, suggesting that extremely high resolution PM2.5 predictions may not be necessary for effective urban epidemiological analysis at the county level.
- Open Access
- 25 November 2021
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 21 (22) , 17115-17132
Changes in PM2.5 concentrations and their sources in the US from 1990 to 2010
Significant reductions in emissions of SO2, NOx, volatile organic compounds (VOCs), and primary particulate matter (PM) took place in the US from 1990 to 2010. We evaluate here our understanding of the links between these emissions changes and corresponding changes in concentrations and health outcomes using a chemical transport model, the Particulate Matter Comprehensive Air Quality Model with Extensions (PMCAMx), for 1990, 2001, and 2010. The use of the Particle Source Apportionment Algorithm (PSAT) allows us to link the concentration reductions to the sources of the corresponding primary and secondary PM. The reductions in SO2 emissions (64 %, mainly from electric-generating units) during these 20 years have dominated the reductions in PM2.5, leading to a 45 % reduction in sulfate levels. The predicted sulfate reductions are in excellent agreement with the available measurements. Also, the reductions in elemental carbon (EC) emissions (mainly from transportation) have led to a 30 % reduction in EC concentrations. The most important source of organic aerosol (OA) through the years according to PMCAMx is biomass burning, followed by biogenic secondary organic aerosol (SOA). OA from on-road transport has been reduced by more than a factor of 3. On the other hand, changes in biomass burning OA and biogenic SOA have been modest. In 1990, about half of the US population was exposed to annual average PM2.5 concentrations above 20 µg m−3, but by 2010 this fraction had dropped to practically zero. The predicted changes in concentrations are evaluated against the observed changes for 1990, 2001, and 2010 in order to understand whether the model represents reasonably well the corresponding processes caused by the changes in emissions.
- 25 November 2021
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 21 (22) , 17115-17132
Open AccessChanges in PM2.5 concentrations and their sources in the US from 1990 to 2010
Significant reductions in emissions of SO2, NOx, volatile organic compounds (VOCs), and primary particulate matter (PM) took place in the US from 1990 to 2010. We evaluate here our understanding of the links between these emissions changes and corresponding changes in concentrations and health outcomes using a chemical transport model, the Particulate Matter Comprehensive Air Quality Model with Extensions (PMCAMx), for 1990, 2001, and 2010. The use of the Particle Source Apportionment Algorithm (PSAT) allows us to link the concentration reductions to the sources of the corresponding primary and secondary PM. The reductions in SO2 emissions (64 %, mainly from electric-generating units) during these 20 years have dominated the reductions in PM2.5, leading to a 45 % reduction in sulfate levels. The predicted sulfate reductions are in excellent agreement with the available measurements. Also, the reductions in elemental carbon (EC) emissions (mainly from transportation) have led to a 30 % reduction in EC concentrations. The most important source of organic aerosol (OA) through the years according to PMCAMx is biomass burning, followed by biogenic secondary organic aerosol (SOA). OA from on-road transport has been reduced by more than a factor of 3. On the other hand, changes in biomass burning OA and biogenic SOA have been modest. In 1990, about half of the US population was exposed to annual average PM2.5 concentrations above 20 µg m−3, but by 2010 this fraction had dropped to practically zero. The predicted changes in concentrations are evaluated against the observed changes for 1990, 2001, and 2010 in order to understand whether the model represents reasonably well the corresponding processes caused by the changes in emissions.