Henry R. Halperin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Henry R. Halperin has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
Albert Lardo
3 shared publications- David A. Bluemke
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
3 shared publications - Luca Neri
Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA
3 shared publications Saman Nazarian
Division of Cariovascular Medicine, Hospital of the University of Pennsylvania, PA, United States
3 shared publications- Anthony L. Gunderman
Mechanical Engineering Department, University of Arkansas, Fayetteville, AR, USA
2 shared publications Ariel Roguin
From Johns Hopkins University, Baltimore, Maryland; Rambam Medical Center, Technion Institute of Technology, Haifa, Israel; and Radiology and Imaging Sciences, National Institutes of Biomedical Imaging and Bioengineering, Bethesda, Maryland
2 shared publications
Latest Publications
- 23 September 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (12) , 902-904
The Association of Time to Reperfusion With VA-ECMO With Survival of Patients Who Experience Refractory Out-of-Hospital Cardiac Arrest
- 23 September 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (12) , 902-904
The Association of Time to Reperfusion With VA-ECMO With Survival of Patients Who Experience Refractory Out-of-Hospital Cardiac Arrest
- Open Access
- 13 February 2025
- Published by Springer Nature in Journal of Transformative Technologies and Sustainable Development
- Vol. 9 (1) , 1-10
Cardiac Safety Using a Swine Surrogate Model for a New Concept Conducted Electrical Weapon—The TASER® T10
Axon Enterprise, Inc. has developed a new concept Conducted Electrical Weapon (CEW). Instead of the traditional electrically paired two- or four-probe design, the new CEW uses variable probe polarity with ten independently targeted probes. With this design, electrical connections can occur between any connected probes. With ten probes independently targeted, the manufacturer is expecting field efficacy to be higher than the traditional CEW designs. With the capability of up to ten probes on target (the current firmware limits the total connections between probes to 4), the possibility of anterior–posterior transthoracic connections, probes potentially rapidly alternating polarity (which has never been studied), and a new waveform that varies with the load, this new CEW presents new areas for cardiac safety study. The authors used their previously published swine cardiac safety surrogate testing model using hypotensive cardiac capture and ventricular fibrillation as the clinical endpoints to compare the new CEW to two prior generation CEW models, the TASER 7™ and the TASER X26E™, specifically examining multiple probes, anterior–posterior connections, and rapid alternating probe polarities. The drop in mean arterial blood pressure (MAP) during exposures or ventricular fibrillation was the primary end point of interest. The exposure groups were two probes, two probes anterior–posterior, three probes, and four probes. There were a total of 265 thoracic (≥ one probe on the chest) exposures over five swine. A Kruskal–Wallis test assessing for differences in MAP change by weapon did not show any difference (p = 0.35). There were no instances of ventricular fibrillation. Based on this study, there was not a statistical difference between the CEWs in the clinical endpoints of interest. There was an increase in MAP drop with anterior–posterior connections compared to matched anterior-only connections with the TASER 10. This connection was not studied with the other weapons.
- 13 February 2025
- Published by Springer Nature in Journal of Transformative Technologies and Sustainable Development
- Vol. 9 (1) , 1-10
Open AccessCardiac Safety Using a Swine Surrogate Model for a New Concept Conducted Electrical Weapon—The TASER® T10
Axon Enterprise, Inc. has developed a new concept Conducted Electrical Weapon (CEW). Instead of the traditional electrically paired two- or four-probe design, the new CEW uses variable probe polarity with ten independently targeted probes. With this design, electrical connections can occur between any connected probes. With ten probes independently targeted, the manufacturer is expecting field efficacy to be higher than the traditional CEW designs. With the capability of up to ten probes on target (the current firmware limits the total connections between probes to 4), the possibility of anterior–posterior transthoracic connections, probes potentially rapidly alternating polarity (which has never been studied), and a new waveform that varies with the load, this new CEW presents new areas for cardiac safety study. The authors used their previously published swine cardiac safety surrogate testing model using hypotensive cardiac capture and ventricular fibrillation as the clinical endpoints to compare the new CEW to two prior generation CEW models, the TASER 7™ and the TASER X26E™, specifically examining multiple probes, anterior–posterior connections, and rapid alternating probe polarities. The drop in mean arterial blood pressure (MAP) during exposures or ventricular fibrillation was the primary end point of interest. The exposure groups were two probes, two probes anterior–posterior, three probes, and four probes. There were a total of 265 thoracic (≥ one probe on the chest) exposures over five swine. A Kruskal–Wallis test assessing for differences in MAP change by weapon did not show any difference (p = 0.35). There were no instances of ventricular fibrillation. Based on this study, there was not a statistical difference between the CEWs in the clinical endpoints of interest. There was an increase in MAP drop with anterior–posterior connections compared to matched anterior-only connections with the TASER 10. This connection was not studied with the other weapons.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2131-2142
MR-Safe Cartesian Platform for Active Cardiac Shimming: Preliminary Validation
Objective: Implanted Cardioverter Defibrillators (ICDs) induce a large (100 parts per million) inhomogeneous magnetic field in the magnetic resonance imaging (MRI) scanner which cannot be corrected by the scanner's built-in shim coils, leading to significant image artifacts that can make portions of the heart unreadable. To compensate for the field inhomogeneity, an active shim coil capable of countering the field deviation in user-defined regions was designed that must be optimally placed at patient-specific locations. We aim to develop and evaluate an MR-safe robotic solution for automated shim coil positioning. Methods: We designed and fabricated an MR-safe Cartesian platform that holds the shim coil inside the scanner. The platform consists of three lead screw stages actuated by pneumatic motors, achieving decoupled translations of 140 mm in each direction. The platform is made of plastics and fiberglass with the control electronics placed outside the scanner room, ensuring MR safety. Mechanical modeling was derived to provide design specifications. Results: Experiments show that the platform achieves less than 2 mm average motion error and 0.5 mm repeatability in all directions, and reduces the adjustment time from $>$ 5 min to a few seconds. Phantom and animal trials were conducted, showing that the proposed system is able to position a heavy shim coil ( $\mathbf {>3}$ kg) for improved ICD artifact suppression. Conclusion: This robotic platform provides an effective method for reliable shim coil positioning inside the scanner. Significance: This work contributes to improving cardiac MRI quality that could facilitate accurate diagnosis and treatment planning for patients with implanted ICDs.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2131-2142
MR-Safe Cartesian Platform for Active Cardiac Shimming: Preliminary Validation
Objective: Implanted Cardioverter Defibrillators (ICDs) induce a large (100 parts per million) inhomogeneous magnetic field in the magnetic resonance imaging (MRI) scanner which cannot be corrected by the scanner's built-in shim coils, leading to significant image artifacts that can make portions of the heart unreadable. To compensate for the field inhomogeneity, an active shim coil capable of countering the field deviation in user-defined regions was designed that must be optimally placed at patient-specific locations. We aim to develop and evaluate an MR-safe robotic solution for automated shim coil positioning. Methods: We designed and fabricated an MR-safe Cartesian platform that holds the shim coil inside the scanner. The platform consists of three lead screw stages actuated by pneumatic motors, achieving decoupled translations of 140 mm in each direction. The platform is made of plastics and fiberglass with the control electronics placed outside the scanner room, ensuring MR safety. Mechanical modeling was derived to provide design specifications. Results: Experiments show that the platform achieves less than 2 mm average motion error and 0.5 mm repeatability in all directions, and reduces the adjustment time from $>$ 5 min to a few seconds. Phantom and animal trials were conducted, showing that the proposed system is able to position a heavy shim coil ( $\mathbf {>3}$ kg) for improved ICD artifact suppression. Conclusion: This robotic platform provides an effective method for reliable shim coil positioning inside the scanner. Significance: This work contributes to improving cardiac MRI quality that could facilitate accurate diagnosis and treatment planning for patients with implanted ICDs.
- Top Cited PapersOpen Access
Electrocardiogram Monitoring Wearable Devices and Artificial-Intelligence-Enabled Diagnostic Capabilities: A Review
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.
Top Cited PapersOpen AccessElectrocardiogram Monitoring Wearable Devices and Artificial-Intelligence-Enabled Diagnostic Capabilities: A Review
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.
- Open Access
Algorithm for Mobile Platform-Based Real-Time QRS Detection
Recent advancements in smart, wearable technologies have allowed the detection of various medical conditions. In particular, continuous collection and real-time analysis of electrocardiogram data have enabled the early identification of pathologic cardiac rhythms. Various algorithms to assess cardiac rhythms have been developed, but these utilize excessive computational power. Therefore, adoption to mobile platforms requires more computationally efficient algorithms that do not sacrifice correctness. This study presents a modified QRS detection algorithm, the AccYouRate Modified Pan–Tompkins (AMPT), which is a simplified version of the well-established Pan–Tompkins algorithm. Using archived ECG data from a variety of publicly available datasets, relative to the Pan–Tompkins, the AMPT algorithm demonstrated improved computational efficiency by 5–20×, while also universally enhancing correctness, both of which favor translation to a mobile platform for continuous, real-time QRS detection.
Open AccessAlgorithm for Mobile Platform-Based Real-Time QRS Detection
Recent advancements in smart, wearable technologies have allowed the detection of various medical conditions. In particular, continuous collection and real-time analysis of electrocardiogram data have enabled the early identification of pathologic cardiac rhythms. Various algorithms to assess cardiac rhythms have been developed, but these utilize excessive computational power. Therefore, adoption to mobile platforms requires more computationally efficient algorithms that do not sacrifice correctness. This study presents a modified QRS detection algorithm, the AccYouRate Modified Pan–Tompkins (AMPT), which is a simplified version of the well-established Pan–Tompkins algorithm. Using archived ECG data from a variety of publicly available datasets, relative to the Pan–Tompkins, the AMPT algorithm demonstrated improved computational efficiency by 5–20×, while also universally enhancing correctness, both of which favor translation to a mobile platform for continuous, real-time QRS detection.
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 28 (4) , 2405-2410
MRI-Conditional Eccentric-Tube Injection Needle: Design, Fabrication, and Animal Trial
Effective radiation therapy aims to maximize the radiation dose delivered to the tumor, while minimizing damage to the surrounding healthy tissues, which can be a challenging task when the tissue–tumor space is small. To eliminate the damage to healthy tissue, it is now possible to inject biocompatible hydrogels between cancerous targets and surrounding tissues to create a spacer pocket. Conventional methods have limitations in poor target visualization and device tracking. In this article, we leverage our MR-tracking technique to develop a novel injection needle for hydrogel spacer deployment. Herein, we present the working principle and fabrication method, followed by benchtop validation in an agar phantom, and magnetic resonance imaging (MRI)-guided validation in tissue-mimic prostate phantom and sexually mature female swine. Animal trials indicated that the spacer pockets in the rectovaginal septum can be accurately visualized on T2-weighted MRI. The experimental results showed that the vaginal–rectal spacing was successfully increased by 12 $ \pm {\bm{\ }}$ 2 mm anterior–posterior.
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 28 (4) , 2405-2410
MRI-Conditional Eccentric-Tube Injection Needle: Design, Fabrication, and Animal Trial
Effective radiation therapy aims to maximize the radiation dose delivered to the tumor, while minimizing damage to the surrounding healthy tissues, which can be a challenging task when the tissue–tumor space is small. To eliminate the damage to healthy tissue, it is now possible to inject biocompatible hydrogels between cancerous targets and surrounding tissues to create a spacer pocket. Conventional methods have limitations in poor target visualization and device tracking. In this article, we leverage our MR-tracking technique to develop a novel injection needle for hydrogel spacer deployment. Herein, we present the working principle and fabrication method, followed by benchtop validation in an agar phantom, and magnetic resonance imaging (MRI)-guided validation in tissue-mimic prostate phantom and sexually mature female swine. Animal trials indicated that the spacer pockets in the rectovaginal septum can be accurately visualized on T2-weighted MRI. The experimental results showed that the vaginal–rectal spacing was successfully increased by 12 $ \pm {\bm{\ }}$ 2 mm anterior–posterior.
- 17 October 2022
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 8 (10) , 1271-1273
New Insights Into Cardiac Arrest From Pulseless Electrical Activity
- 17 October 2022
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 8 (10) , 1271-1273
New Insights Into Cardiac Arrest From Pulseless Electrical Activity
- Open Access
- 1 October 2022
- Published by Elsevier in Trends in Cardiovascular Medicine
- Vol. 32 (7) , 440-447
Magnetic resonance imaging safety in patients with cardiac implantable electronic devices
- 1 October 2022
- Published by Elsevier in Trends in Cardiovascular Medicine
- Vol. 32 (7) , 440-447
Open AccessMagnetic resonance imaging safety in patients with cardiac implantable electronic devices
- Open Access
- 18 October 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Extrapolation of Ventricular Activation Times From Sparse Electroanatomical Data Using Graph Convolutional Neural Networks
Electroanatomic mapping is the gold standard for the assessment of ventricular tachycardia. Acquiring high resolution electroanatomic maps is technically challenging and may require interpolation methods to obtain dense measurements. These methods, however, cannot recover activation times in the entire biventricular domain. This work investigates the use of graph convolutional neural networks to estimate biventricular activation times from sparse measurements. Our method is trained on more than 15,000 synthetic examples of realistic ventricular depolarization patterns generated by a computational electrophysiology model. Using geometries sampled from a statistical shape model of biventricular anatomy, diverse wave dynamics are induced by randomly sampling scar and border zone distributions, locations of initial activation, and tissue conduction velocities. Once trained, the method accurately reconstructs biventricular activation times in left-out synthetic simulations with a mean absolute error of 3.9 ms ± 4.2 ms at a sampling density of one measurement sample per cm2. The total activation time is matched with a mean error of 1.4 ms ± 1.4 ms. A significant decrease in errors is observed in all heart zones with an increased number of samples. Without re-training, the network is further evaluated on two datasets: (1) an in-house dataset comprising four ischemic porcine hearts with dense endocardial activation maps; (2) the CRT-EPIGGY19 challenge data comprising endo- and epicardial measurements of 5 infarcted and 6 non-infarcted swines. In both setups the neural network recovers biventricular activation times with a mean absolute error of less than 10 ms even when providing only a subset of endocardial measurements as input. Furthermore, we present a simple approach to suggest new measurement locations in real-time based on the estimated uncertainty of the graph network predictions. The model-guided selection of measurement locations allows to reduce by 40% the number of measurements required in a random sampling strategy, while achieving the same prediction error. In all the tested scenarios, the proposed approach estimates biventricular activation times with comparable or better performance than a personalized computational model and significant runtime advantages.
- 18 October 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessExtrapolation of Ventricular Activation Times From Sparse Electroanatomical Data Using Graph Convolutional Neural Networks
Electroanatomic mapping is the gold standard for the assessment of ventricular tachycardia. Acquiring high resolution electroanatomic maps is technically challenging and may require interpolation methods to obtain dense measurements. These methods, however, cannot recover activation times in the entire biventricular domain. This work investigates the use of graph convolutional neural networks to estimate biventricular activation times from sparse measurements. Our method is trained on more than 15,000 synthetic examples of realistic ventricular depolarization patterns generated by a computational electrophysiology model. Using geometries sampled from a statistical shape model of biventricular anatomy, diverse wave dynamics are induced by randomly sampling scar and border zone distributions, locations of initial activation, and tissue conduction velocities. Once trained, the method accurately reconstructs biventricular activation times in left-out synthetic simulations with a mean absolute error of 3.9 ms ± 4.2 ms at a sampling density of one measurement sample per cm2. The total activation time is matched with a mean error of 1.4 ms ± 1.4 ms. A significant decrease in errors is observed in all heart zones with an increased number of samples. Without re-training, the network is further evaluated on two datasets: (1) an in-house dataset comprising four ischemic porcine hearts with dense endocardial activation maps; (2) the CRT-EPIGGY19 challenge data comprising endo- and epicardial measurements of 5 infarcted and 6 non-infarcted swines. In both setups the neural network recovers biventricular activation times with a mean absolute error of less than 10 ms even when providing only a subset of endocardial measurements as input. Furthermore, we present a simple approach to suggest new measurement locations in real-time based on the estimated uncertainty of the graph network predictions. The model-guided selection of measurement locations allows to reduce by 40% the number of measurements required in a random sampling strategy, while achieving the same prediction error. In all the tested scenarios, the proposed approach estimates biventricular activation times with comparable or better performance than a personalized computational model and significant runtime advantages.
- Open Access
- 6 July 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (13) , e018671
Pulseless Electrical Activity as the Initial Cardiac Arrest Rhythm: Importance of Preexisting Left Ventricular Function
Background: Pulseless electrical activity (PEA) is a common initial rhythm in cardiac arrest. A substantial number of PEA arrests are caused by coronary ischemia in the setting of acute coronary occlusion, but the underlying mechanism is not well understood. We hypothesized that the initial rhythm in patients with acute coronary occlusion is more likely to be PEA than ventricular fibrillation in those with prearrest severe left ventricular dysfunction. Methods and Results: We studied the initial cardiac arrest rhythm induced by acute left anterior descending coronary occlusion in swine without and with preexisting severe left ventricular dysfunction induced by prior infarcts in non–left anterior descending coronary territories. Balloon occlusion resulted in ventricular fibrillation in 18 of 34 naïve animals, occurring 23.5±9.0 minutes following occlusion, and PEA in 1 animal. However, all 18 animals with severe prearrest left ventricular dysfunction (ejection fraction 15±5%) developed PEA 1.7±1.1 minutes after occlusion. Conclusions: Acute coronary ischemia in the setting of severe left ventricular dysfunction produces PEA because of acute pump failure, which occurs almost immediately after coronary occlusion. After the onset of coronary ischemia, PEA occurred significantly earlier than ventricular fibrillation (<2 minutes versus 20 minutes). These findings support the notion that patients with baseline left ventricular dysfunction and suspected coronary disease who develop PEA should be evaluated for acute coronary occlusion.
- 6 July 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (13) , e018671
Open AccessPulseless Electrical Activity as the Initial Cardiac Arrest Rhythm: Importance of Preexisting Left Ventricular Function
Background: Pulseless electrical activity (PEA) is a common initial rhythm in cardiac arrest. A substantial number of PEA arrests are caused by coronary ischemia in the setting of acute coronary occlusion, but the underlying mechanism is not well understood. We hypothesized that the initial rhythm in patients with acute coronary occlusion is more likely to be PEA than ventricular fibrillation in those with prearrest severe left ventricular dysfunction. Methods and Results: We studied the initial cardiac arrest rhythm induced by acute left anterior descending coronary occlusion in swine without and with preexisting severe left ventricular dysfunction induced by prior infarcts in non–left anterior descending coronary territories. Balloon occlusion resulted in ventricular fibrillation in 18 of 34 naïve animals, occurring 23.5±9.0 minutes following occlusion, and PEA in 1 animal. However, all 18 animals with severe prearrest left ventricular dysfunction (ejection fraction 15±5%) developed PEA 1.7±1.1 minutes after occlusion. Conclusions: Acute coronary ischemia in the setting of severe left ventricular dysfunction produces PEA because of acute pump failure, which occurs almost immediately after coronary occlusion. After the onset of coronary ischemia, PEA occurred significantly earlier than ventricular fibrillation (<2 minutes versus 20 minutes). These findings support the notion that patients with baseline left ventricular dysfunction and suspected coronary disease who develop PEA should be evaluated for acute coronary occlusion.