Ishita Bansal
Ishita Bansal has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Amit Prabhakar
Indian Institute of Information Technology Allahabad, Prayagraj, India
1 shared publication Ankur Jaiswar
Department of Applied Sciences, Indian Institute of Information Technology Allahabad, Allahabad 211015, India
1 shared publicationDeepti Verma
Department of Chemistry, University of Allahabad, Allahabad 211002, India
1 shared publication- Nimisha Roy
Department of Applied Sciences, Indian Institute of Information Technology Allahabad, Allahabad 211015, India
1 shared publication - Nishant Kumar Sharma1 shared publication
- Nitish Sagar
Accenture Labs
1 shared publication
Latest Publications
- Open Access
Machine learning assisted multi-level differentiation of blood cells using multi-frequency electro-mechanical impedance cytometry
We report a multi-frequency microfluidic impedance cytometer with multimodal measurement of electrical and mechanical cell properties. Using the large feature set from the multimodality, we implemented machine learning assisted differentiation of cells. We have demonstrated a constriction-equipped channel to study the mechanical cell properties, and integrated multiple microelectrodes that capture electric field information pertaining to various stages of cell transit. Our system works over a wide frequency range from 800 kHz to 8 MHz. We developed a machine learning workflow to classify cells using our multi-modal data. Using this platform to show blood cell differentiation, our system shows minimum F1 score to be 0.92, minimizing both false negatives and false positives, which is important for medical diagnosis. Furthermore, we also identified the presence of two populations in the mixed sample of neutrophils and PBMCs. Our workflow allows classification of cells in a new sample along with identification of top 5 distinguishing parameters out of 70+ features extracted from the raw impedance signal.
Open AccessMachine learning assisted multi-level differentiation of blood cells using multi-frequency electro-mechanical impedance cytometry
We report a multi-frequency microfluidic impedance cytometer with multimodal measurement of electrical and mechanical cell properties. Using the large feature set from the multimodality, we implemented machine learning assisted differentiation of cells. We have demonstrated a constriction-equipped channel to study the mechanical cell properties, and integrated multiple microelectrodes that capture electric field information pertaining to various stages of cell transit. Our system works over a wide frequency range from 800 kHz to 8 MHz. We developed a machine learning workflow to classify cells using our multi-modal data. Using this platform to show blood cell differentiation, our system shows minimum F1 score to be 0.92, minimizing both false negatives and false positives, which is important for medical diagnosis. Furthermore, we also identified the presence of two populations in the mixed sample of neutrophils and PBMCs. Our workflow allows classification of cells in a new sample along with identification of top 5 distinguishing parameters out of 70+ features extracted from the raw impedance signal.
- Open Access
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
Nano-fluidic Peristaltic Pump Employing Thermally Decoupled Shape Memory Alloy Actuation Using Mechanical Isolation Interfaces
The development of compact, efficient fluidic systems for manipulation of fluids at small scale has driven significant interest in shape memory alloys (SMAs) for their ability to deform under thermal loading and regain their original shape upon unloading. However, a critical obstacle to their integration, particularly in peristaltic pumps, is the significant heat generated during actuation, which can compromise the integrity of temperature-sensitive tubing and fluids, especially while handling biological fluids. This paper introduces the design and characterization of an SMA-based peristaltic pump that reduces the fluid conduit temperature to ambient temperature, compared with 55°C in a direct wrap approach. A key innovation of this design is the integration of a mechanical isolator between the SMA actuator and the pump tubing. These isolators prevent heat transfer without impeding the mechanical force required for the peristaltic motion. Experimental results validate the efficacy of this isolation method, demonstrating consistent pumping performance (60 – 180 nL/s) while maintaining the conveyed fluid's temperature at ambient temperature and preserving the integrity of the tubing. The proposed design offers a reliable, compact, and thermally isolated solution for a wide range of applications in biomedical, microfluidic, and chemical engineering.
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNano-fluidic Peristaltic Pump Employing Thermally Decoupled Shape Memory Alloy Actuation Using Mechanical Isolation Interfaces
The development of compact, efficient fluidic systems for manipulation of fluids at small scale has driven significant interest in shape memory alloys (SMAs) for their ability to deform under thermal loading and regain their original shape upon unloading. However, a critical obstacle to their integration, particularly in peristaltic pumps, is the significant heat generated during actuation, which can compromise the integrity of temperature-sensitive tubing and fluids, especially while handling biological fluids. This paper introduces the design and characterization of an SMA-based peristaltic pump that reduces the fluid conduit temperature to ambient temperature, compared with 55°C in a direct wrap approach. A key innovation of this design is the integration of a mechanical isolator between the SMA actuator and the pump tubing. These isolators prevent heat transfer without impeding the mechanical force required for the peristaltic motion. Experimental results validate the efficacy of this isolation method, demonstrating consistent pumping performance (60 – 180 nL/s) while maintaining the conveyed fluid's temperature at ambient temperature and preserving the integrity of the tubing. The proposed design offers a reliable, compact, and thermally isolated solution for a wide range of applications in biomedical, microfluidic, and chemical engineering.
- 1 January 2023
- Published by Elsevier in Materials Today: Proceedings
- Vol. 80, 1852-1857
A simple cost-effective microfluidic platform for rapid synthesis of diverse metal nanoparticles: A novel approach towards fighting SARS-CoV-2
- 1 January 2023
- Published by Elsevier in Materials Today: Proceedings
- Vol. 80, 1852-1857
A simple cost-effective microfluidic platform for rapid synthesis of diverse metal nanoparticles: A novel approach towards fighting SARS-CoV-2