June-Yeon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
June-Yeon Lee has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Gu-Hee Jung
Department of Orthopedic Surgery, Gyeongsang National University Changwon Hospital, Gyeongsang National University College of Medicine, Changwon, Korea
2 shared publications - Hyeon Joon Lee
Ulsan University Hospital, Ulsan, Republic of Korea
2 shared publications - Jae-Hwan Lim
Department of Orthopaedic Surgery, Gwangju Suwan Hospital, Gwangju, Korea
2 shared publications
Latest Publications
- 6 July 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (1) , 48
Correction to: Implications of the Overlapping Degree Between Proximal Fibula and Tibia for Placing the Optimal Syndesmotic Screw: A Virtual Cadaveric Study
[This corrects the article DOI: 10.1007/s43465-021-00437-y.].
- 6 July 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (1) , 48
Correction to: Implications of the Overlapping Degree Between Proximal Fibula and Tibia for Placing the Optimal Syndesmotic Screw: A Virtual Cadaveric Study
[This corrects the article DOI: 10.1007/s43465-021-00437-y.].
- 15 June 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (1) , 41-47
Implications of the Overlapping Degree Between Proximal Fibula and Tibia for Placing the Optimal Syndesmotic Screw: A Virtual Cadaveric Study
Background To determine the optimal direction of the syndesmotic screw and to introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation. Methods A total of 105 cadaveric lower legs (50 males and 55 females; average height, 160.6 ± 7.1 cm) were used to reconstruct a 3D model by using the Mimics® software and the joint morphology was evaluated. Syndesmotic cylinders (Ø3.5 mm/Length 100 mm) were transversely placed in the proximal end of the incisura fibularis for simulating screw fixation. The tibial proximal cylinder, which was tangent to the posterior tibial condyles, was traced and the angle between the two cylinders was measured as the tibial torsion angle (TTA). After rotating the syndesmotic cylinder parallel to the ground, the overlapping degree between the proximal fibula and tibia was assessed as a radiologic indicator. Results Concerning tibial torsion, the TTA was an average of 36.7° (range, 17.2°–54.4°; SD, 8.78) When the syndesmotic cylinder was rotated to be parallel to the ground, the proximal fibula had nonlinear or linear overlap with the lateral border of the tibia, regardless of the joint morphology. In this non-overlapping view, three Weber’s indices for normal fibular length could be better visualized than the mortise view. Conclusion The syndesmotic cylinder in the proximal end of the incisura fibularis could be consistently placed parallel to the ground by internally rotating the tibia until there was a nonlinear or linear overlap between the proximal fibula and the tibia, regardless of the joint morphology.
- 15 June 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (1) , 41-47
Implications of the Overlapping Degree Between Proximal Fibula and Tibia for Placing the Optimal Syndesmotic Screw: A Virtual Cadaveric Study
Background To determine the optimal direction of the syndesmotic screw and to introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation. Methods A total of 105 cadaveric lower legs (50 males and 55 females; average height, 160.6 ± 7.1 cm) were used to reconstruct a 3D model by using the Mimics® software and the joint morphology was evaluated. Syndesmotic cylinders (Ø3.5 mm/Length 100 mm) were transversely placed in the proximal end of the incisura fibularis for simulating screw fixation. The tibial proximal cylinder, which was tangent to the posterior tibial condyles, was traced and the angle between the two cylinders was measured as the tibial torsion angle (TTA). After rotating the syndesmotic cylinder parallel to the ground, the overlapping degree between the proximal fibula and tibia was assessed as a radiologic indicator. Results Concerning tibial torsion, the TTA was an average of 36.7° (range, 17.2°–54.4°; SD, 8.78) When the syndesmotic cylinder was rotated to be parallel to the ground, the proximal fibula had nonlinear or linear overlap with the lateral border of the tibia, regardless of the joint morphology. In this non-overlapping view, three Weber’s indices for normal fibular length could be better visualized than the mortise view. Conclusion The syndesmotic cylinder in the proximal end of the incisura fibularis could be consistently placed parallel to the ground by internally rotating the tibia until there was a nonlinear or linear overlap between the proximal fibula and the tibia, regardless of the joint morphology.