HYHuarong Yu

Huarong Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huarong Yu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Intelligent analysis and interpretation of aquatic organic matter fluorescence excitation-emission matrix

    by Yue Wang, Yucheng Wu, Shiqi Liang, Zihan Tang, Chunhai Wei, Huarong Yu, Fangshu Qu

  • Open Access

    Pilot-Scale Evaluation of Flat-Sheet Membrane Bioreactor for In Situ Retrofitting Textile Dyeing Wastewater Treatment Plant

    by Chaoqun Zhou, Chunhai Wei, Huarong Yu, Hongwei Rong, Kang Xiao

    It is promising to in situ retrofit the activated sludge process with a membrane bioreactor (MBR) to increase treatment capacity and improve effluent quality in a textile dyeing wastewater treatment plant (WWTP). Membrane selection among commercial products for real engineering applications is critical for this specific wastewater, and little information is available in the literature. This study systematically evaluated the application potential of two flat-sheet microfiltration membranes made of polyvinylidene fluoride (PVDF) and polyether sulfone (PES) in pilot-scale MBRs for in situ retrofitting textile dyeing WWTP. During the four stages with different loads, both membranes achieved nearly the same effluent quality and rejection performance. Both membranes showed little trans-membrane pressure (TMP) increase at an average flux of 15 L/(m2·h) with sub-critical flux characteristics, and showed a sharp TMP increase with super-critical flux characteristics observed at an average flux of 18/22.5 L/(m2·h). After 74 d of filtration, at an average sludge concentration of 12,000 g/L, the PVDF membrane showed less variation in pore size distribution and bubble point pressure, while the PES membrane showed less change in permeability and contact angle. Both membranes met general MBR requirements due to the minimizing pristine effects of both membranes by this specific wastewater matrix. The PVDF membrane showed better anti-fouling capability, especially during high-/over-load stages, and thus was suggested for MBR retrofit, with a sustainable membrane flux below 18 L/(m2·h).


  • Multi-spectroscopy reveals selective oxidation for ultrafiltration membrane fouling control in wastewater reuse

    by Qingshui Fan, Huarong Yu, Yuxuan Wan, Haiyang Yang, Zhihui Pan, Fangshu Qu


  • Simultaneous ammonium and water recovery from landfill leachate using an integrated two-stage membrane distillation

    by Haiyang Yang, Qinsen Liu, Xinying Shu, Huarong Yu, Hongwei Rong, Fangshu Qu, Heng Liang


  • Open Access

    UV/Fe(II)/S(IV) Pretreatment for Ultrafiltration of Microcystis aeruginosa-Laden Water: Fe(II)/Fe(III) Triggered Synergistic Oxidation and Coagulation

    by Huarong Yu, Haiyang Yang, Guangmei Wei, Naresh Mameda, Fangshu Qu, Hongwei Rong

    Ultrafiltration (UF) has been proven effective in removing algae during seasonal algal blooms, but the algal cells and the metabolites can induce severe membrane fouling, which undermines the performance and stability of the UF. Ultraviolet-activated sulfite with iron (UV/Fe(II)/S(IV)) could enable an oxidation-reduction coupling circulation and exert synergistic effects of moderate oxidation and coagulation, which would be highly preferred in fouling control. For the first time, the UV/Fe(II)/S(IV) was systematically investigated as a pretreatment of UF for treating Microcystis aeruginosa–laden water. The results showed that the UV/Fe(II)/S(IV) pretreatment significantly improved the removal of organic matter and alleviated membrane fouling. Specifically, the organic matter removal increased by 32.1% and 66.6% with UV/Fe(II)/S(IV) pretreatment for UF of extracellular organic matter (EOM) solution and algae-laden water, respectively, while the final normalized flux increased by 12.0–29.0%, and reversible fouling was mitigated by 35.3–72.5%. The oxysulfur radicals generated in the UV/S(IV) degraded the organic matter and ruptured the algal cells, and the low-molecular-weight organic matter generated in the oxidation penetrated the UF and deteriorated the effluent. The over-oxidation did not happen in the UV/Fe(II)/S(IV) pretreatment, which may be attributed to the cyclic redox Fe(II)/Fe(III) coagulation triggered by the Fe(II). The UV-activated sulfate radicals in the UV/Fe(II)/S(IV) enabled satisfactory organic removal and fouling control without over-oxidation and effluent deterioration. The UV/Fe(II)/S(IV) promoted the aggregation of algal foulants and postponed the shift of the fouling mechanisms from standard pore blocking to cake filtration. The UV/Fe(II)/S(IV) pretreatment proved effective in enhancing the UF for algae-laden water treatment.

  • Synthesis and Characterization of Sewage Sludge Ash-Based Temperature-Sensitive Hydrogel as an Advanced Class of Forward Osmosis Desalination Draw Agent

    by Zhihui Pan, Yingru Huang, Xiongrui Yang, Yilun Liang, Junguo He, Huarong Yu

    In this study, an advanced temperature-sensitive hydrogel with sewage sludge ash (SSA) was synthesized and employed as draw agent for forward osmosis (FO) desalination. The effects of the incineration temperature (700–1,000°C) of SSA obtention, particle size (20–300 meshes), and dosage (0–4.5 wt%) of SSA were investigated for optimally synthesizing the temperature-sensitive hydrogel to meet the requirement of FO. The resulting hydrogels were characterized in terms of crystal structure, surface morphology, surface functional groups, and lower critical solution temperature (LCST). It was shown that the dosage of SSA significantly influenced the swelling capacity (in different concentrations of NaCl solution) and deswelling property of hydrogels, whereas the other two factors only affected the swelling of hydrogel, but had no effect on the deswelling. In addition, as a result of higher reticulated pore structure, and the hydrogen-bonding interaction between the chemical surface of SSA and monomers of hydrogels, the best production D2.5H as a draw agent generated high average water flux of 2.22 LMH in FO desalination with 2,000 ppm NaCl as feed solution. Furthermore, despite a little higher LCST with the comparison of D0H (blank sample without SSA), the D2.5H as a draw agent can still maintain the prominent temperature-sensitive performance in that, most of the water can be recovered in 10 min of 60°C water bath, and the average water fluxes of FO with even three times regenerated hydrogels were similar to that with the initial.


  • Open Access

    Chemical Cleaning and Membrane Aging in MBR for Textile Wastewater Treatment

    by Huarong Yu, Siyuan Shangguan, Chenyu Xie, Haiyang Yang, Chunhai Wei, Hongwei Rong, Fangshu Qu

    Membrane bioreactors have been widely used in textile wastewater treatment. Intensive chemical cleaning is indispensable in the MBR for textile wastewater treatment due to the severe membrane fouling implied. This work investigated the aging of three different membranes, polyvinylidene fluoride (PVDF), polyether sulfone (PES), and polytetrafluoroethylene (PTFE), in the MBRs for textile wastewater treatment. Pilot-scale MBRs were operated and the used membrane was characterized. Batch chemical soaking tests were conducted to elucidate the aging properties of the membranes. The results indicated that the PVDF membrane was most liable to the chemical cleaning, and the PES and PTFE membranes were rather stable. The surface hydrophobicity of the PVDF increased in the acid aging test, and the pore size and pure water flux decreased due to the elevated hydrophobic effect; alkaline oxide aging destructed the structure of the PVDF membrane, enlarged pore size, and increased pure water flux. Chemical cleaning only altered the interfacial properties (hydrophobicity and surface zeta potential) of the PES and PTFE membranes. The fluoro-substitution and the dehydrofluorination of the PVDF, chain scission of the PES molecules, and dehydrofluorination of the PTFE were observed in aging. A chemically stable and anti-aging membrane would be of great importance in the MBR for textile wastewater treatment due to the intensive chemical cleaning applied.