Dong-Ping Cai
Dong-Ping Cai has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yong-Ming He
Division of Cardiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
4 shared publications Xiang-Jun Yang
Division of Cardiology, the First Affiliated Hospital of Soochow University, PR China
3 shared publicationsHai-Feng Xu
Division of Cardiology, the First Affiliated Hospital of Soochow University, 188 Shizi Ave., Gusu District, Suzhou City, Jiangsu Province, 215006, P. R. China
2 shared publicationsFang Fang
Beijing Aznhen Hospital, Beijing Heart, Lung and Blood Vessel Disease, Capital Medical University, Beijing, PR China
1 shared publicationFeng-Mei Cui
State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, PR China
1 shared publicationJian-Ying Tao
Division of Obstetrics, Suzhou Municipal Hospital, PR China
1 shared publication
Latest Publications
- 1 February 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 501, 1-5
Interaction of lipoprotein(a) with low-density lipoprotein cholesterol on first incident acute myocardial infarction
- 1 February 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 501, 1-5
Interaction of lipoprotein(a) with low-density lipoprotein cholesterol on first incident acute myocardial infarction
- Open Access
- 20 September 2018
- Published by Springer Nature in BMC Oral Health
- Vol. 18 (1) , 158
Direct resin composite restoration of maxillary central incisors using a 3D-printed template: two clinical cases
Three-dimensional (3D) printing technology is used widely in dentistry for applications including implant surgery, oral and maxillofacial surgery, orthognathic surgery, endodontics and prosthodontics. Using a 3D-printed template makes performing the repair procedure faster and more convenient. The aesthetic restoration of anterior teeth can recover facial beauty, enhance speaking and chewing functions and improve the quality of life of the patient. This article describes two kinds of clinical cases including fractured teeth and dental caries. In both, a 3D-printed template was used for direct resin composite restoration of maxillary central incisors. A 3D-printed template was built using the following 3-step process: data acquisition was conducted via intra-oral scanning, virtual modeling was performed using an imaging process, and manufacturing was performed using a 3D printer. Aesthetically restoring the maxillary incisors with the assistance of the 3D-printed template achieved the anticipated results, and the patients were very satisfied with the effect. The direct resin composite restoration of maxillary central incisors using a 3D-printed template represents a rapid, convenient, aesthetic and functional option for treating maxillary central incisors. A 3D-printed template is therefore an acceptable and reliable alternative to traditional direct composite restoration of maxillary central incisors including fractured teeth and dental caries.
- 20 September 2018
- Published by Springer Nature in BMC Oral Health
- Vol. 18 (1) , 158
Open AccessDirect resin composite restoration of maxillary central incisors using a 3D-printed template: two clinical cases
Three-dimensional (3D) printing technology is used widely in dentistry for applications including implant surgery, oral and maxillofacial surgery, orthognathic surgery, endodontics and prosthodontics. Using a 3D-printed template makes performing the repair procedure faster and more convenient. The aesthetic restoration of anterior teeth can recover facial beauty, enhance speaking and chewing functions and improve the quality of life of the patient. This article describes two kinds of clinical cases including fractured teeth and dental caries. In both, a 3D-printed template was used for direct resin composite restoration of maxillary central incisors. A 3D-printed template was built using the following 3-step process: data acquisition was conducted via intra-oral scanning, virtual modeling was performed using an imaging process, and manufacturing was performed using a 3D printer. Aesthetically restoring the maxillary incisors with the assistance of the 3D-printed template achieved the anticipated results, and the patients were very satisfied with the effect. The direct resin composite restoration of maxillary central incisors using a 3D-printed template represents a rapid, convenient, aesthetic and functional option for treating maxillary central incisors. A 3D-printed template is therefore an acceptable and reliable alternative to traditional direct composite restoration of maxillary central incisors including fractured teeth and dental caries.
- Open Access
- 17 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35463
Risk burdens of modifiable risk factors incorporating lipoprotein (a) and low serum albumin concentrations for first incident acute myocardial infarction
Risk burdens of modifiable risk factors incorporating lipoprotein (a) (Lp(a)) and low serum albumin (LSA) concentrations for first incident acute myocardial infarction (AMI) haven’t been studied previously. Cross-sectional study of 1552 cases and 6125 controls was performed for identifying the association of risk factors with first incident AMI and their corresponding population attributable risks (PARs). Modifiable risk factors incorporating LSA and Lp(a) accounted for up to 92% of PAR for first incident AMI. Effects of these risk factors were different in different sexes across different age categories. Overall, smoking and LSA were the 2 strongest risk factors, together accounting for 64% of PAR for first incident AMI. After multivariable adjustment, Lp(a) and LSA accounted for 19% and 41%, respectively, and together for more than a half (54%) of PAR for first incident AMI. Modifiable risk factors incorporating LSA and Lp(a) have accounted for an overwhelmingly large proportion of the risk of first incident AMI, indicating most first incident AMI is preventable. The knowledge of risk burdens for first incident AMI incorporating Lp (a) and LSA may be beneficial for further reducing first incident AMI from a new angle.
- 17 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35463
Open AccessRisk burdens of modifiable risk factors incorporating lipoprotein (a) and low serum albumin concentrations for first incident acute myocardial infarction
Risk burdens of modifiable risk factors incorporating lipoprotein (a) (Lp(a)) and low serum albumin (LSA) concentrations for first incident acute myocardial infarction (AMI) haven’t been studied previously. Cross-sectional study of 1552 cases and 6125 controls was performed for identifying the association of risk factors with first incident AMI and their corresponding population attributable risks (PARs). Modifiable risk factors incorporating LSA and Lp(a) accounted for up to 92% of PAR for first incident AMI. Effects of these risk factors were different in different sexes across different age categories. Overall, smoking and LSA were the 2 strongest risk factors, together accounting for 64% of PAR for first incident AMI. After multivariable adjustment, Lp(a) and LSA accounted for 19% and 41%, respectively, and together for more than a half (54%) of PAR for first incident AMI. Modifiable risk factors incorporating LSA and Lp(a) have accounted for an overwhelmingly large proportion of the risk of first incident AMI, indicating most first incident AMI is preventable. The knowledge of risk burdens for first incident AMI incorporating Lp (a) and LSA may be beneficial for further reducing first incident AMI from a new angle.
- Open Access
- 1 January 2016
- Vol. 8 (1) , E75-E77-E77
Daily lifestyles in the fog and haze weather
Daily lifestyles in the fog and haze weather
- 1 January 2016
- Vol. 8 (1) , E75-E77-E77
Open AccessDaily lifestyles in the fog and haze weather
Daily lifestyles in the fog and haze weather