    Radiance-Invariance Evaluation of a Compact LED-Based Source for Imager Radiance Transfer

    by Alberto J. Ruiz, Edwin A. Robledo, Eammon A. Littler

    Significance: Fluorescence imaging remains largely qualitative and device-specific, limiting reproducibility and intersystem comparisons. SI-traceable radiometric imager characterization requires calibrated sources suitable for transferring known radiance to imaging systems. Aim: Establish and evaluate a compact, calibrated solid-state radiometric emitter target (RET) for SI-traceable radiance transfer, and assess methods for evaluating radiance invariance, imager responsivity, and extension of radiance transfer to digitally defined regions of interest (ROIs). Approach: The radiance invariance of an LED-based RET was evaluated by measuring its radiance across varying source-to-aperture distances and collection apertures. A previously described radiance-transfer formalism based on calibrated source radiance and collection geometry was implemented to determine imager responsivity ( R λ ), which was evaluated across varying working distances and lens apertures. Grubbs’ and MAD outlier tests and one-way ANOVA were used to assess radiance and responsivity invariance. Finally, responsivity obtained using digitally defined ROIs was compared with matched physical apertures to assess ROI-based radiance transfer. Results: The measured RET radiance remained invariant across the tested source-to-aperture distances and collection apertures, with no significant differences observed across distance (p = 0.88) or aperture (p = 0.15). Imager responsivity remained stable across working distances for both tested lens configurations (p = 0.48 and p > 0.99). Responsivity was also invariant across lens apertures, except for deviations at f/11 that were consistent with practical aperture tolerances. Digitally defined ROIs reproduced responsivity values obtained using matched physical apertures, demonstrating that the radiance-transfer approach can be extended to image-defined regions. Conclusions: The presented methods provide an approach for evaluating compact LED-based sources for invariant-radiance emission and suitability for SI-traceable radiance transfer. The characterized RET supported stable imager responsivity across changes in imaging geometry and extension to digitally defined ROIs. These methods can be adapted to other LED-based sources, with further angular characterization and uncertainty analysis needed to establish broader applicability.

  • Open Access

    Indocyanine green excitation-emission matrix characterization: excitation-dependent emission shifts and application-specific spectra

    by Alberto J. Ruiz, Sophie A. Lyon, Ethan P. M. LaRochelle, Kimberley S. Samkoe

    SignificanceIndocyanine green (ICG) is the most widely used fluorophore in fluorescence-guided surgery (FGS), and its microenvironment-dependent spectral response is relevant for system design, intersystem comparisons, and phantom development.AimTo characterize ICG with excitation–emission matrices (EEMs) in the microenvironments of dimethyl sulfoxide (DMSO), bovine serum albumin (BSA) solutions, and 3D-printed (3DP) resin and assess excitation-dependent emission, including red-edge excitation shifts (REES) and departures from Kasha’s rule of excitation-independent emission.ApproachEEMs and absorbance spectra were acquired with extracted excitation spectra, emission spectra, emission peaks, centroids, and integrated emission areas under the curves (AUCs). Concentration-dependent behavior was examined in DMSO, and albumin concentration dependence was assessed from 5 to 100 mg/mL. Data processing employed robust local regression to mitigate excitation scattering artifacts.ResultsICG in DMSO exhibited excitation-independent emission consistent with Kasha–Vavilov behavior. By contrast, ICG in BSA solution and 3DP resin displayed excitation-dependent emission with pronounced REES and additional nonlinear departures from Kasha’s rule. To our knowledge, this represents the first documentation of REES and broader anti-Kasha effects for ICG or any FGS fluorophore. Within the excitation range most relevant to ICG-FGS (∼760 to 805 nm), emission spectra of the BSA solution and 3DP resin overlapped closely, with similar AUC-based comparisons, suggesting that ICG in 3DP resin can serve as a suitable surrogate reference for albumin-bound ICG.ConclusionsThe EEM characterization shows that excitation-dependent behavior is a defining feature of ICG in biologically relevant environments, demonstrating that emission cannot be assumed to follow classical Kasha–Vavilov behavior. Reliable comparisons and imaging system design therefore require spectra acquired at defined excitation wavelengths with AUC integration within the emission detection band. Excitation-specific spectra from EEMs establish a consistent framework for intersystem comparisons and phantom standards, whereas the resulting datasets provide a practical spectroscopic reference for addressing excitation-dependent behavior in ICG sensing applications.

  • Open Access

    Evaluation of analytical models to estimate depth of fluorescence objects in biological media

    by Héctor A. García, Hang M. Nguyen, Caleb Y. Kwon, Samuel S. Streeter, Veronica C. Torres, Mayna H. Nguyen, Ethan P. M. LaRochelle, Alberto J. Ruiz, Eric Henderson, Scott C. Davis, et al.

    SignificancePerforming a ratiometric analysis of the fluorescence signals noninvasively measured at two different wavelengths can provide depth estimates of subsurface inner structures in a simple and fast manner, allowing for real-time applications in clinical settings. This can be done using the initially proposed single-excitation–multiple-emission wavelengths approach or by implementing a modified multiple-excitation–single-emission approach; the latter being sometimes preferred due to the larger variation of tissue optical properties at shorter wavelengths. However, previous works validating this method with Monte Carlo (MC) simulations, experiments on tissue-mimicking phantoms, and in vivo measurements on small animal models have reported different degrees of accuracy.AimWe tested the influence of factors not generally accounted for in the analytical model used for data interpretation (e.g., tissue geometry and boundaries, inclusion size and shape, and spectral characteristics of the excitation source). To address these limitations, we developed an improved theoretical framework that explicitly accounts for these factors during data interpretation.ApproachModel validation was carried out with MC simulations and with phantom experiments using indocyanine green as the fluorescence contrast agent. The aimed tissue optical properties were those characteristic of the prostate in a wide range of wavelengths (from 550 to 900 nm).ResultsThe aforementioned factors have a strong influence when changing the original single-excitation–multiple-emission approach to a multiple-excitation–single-emission approach. Though this might make the latter a less preferable method, the low variability of the optical properties in the multiple emission approach (as it happens with prostate tissue) negatively impacts the depth reconstruction process.ConclusionsRegardless of the ratiometric strategy employed, accurate depth estimation requires that the theoretical model closely replicate the experimental conditions. Careful matching of model assumptions to the measurement environment is essential to achieve reliable data interpretation.


  • Open Access

    Quantitative Fluorescence Imaging with SI-Traceable Radiance: Radiometric Fluorescence Characterization with a Calibrated Solid-State Emitter

    by Alberto J. Ruiz, Edwin A. Robledo, Eammon A. Littler

    Significance: Fluorescence imaging remains largely qualitative and device-specific, limiting reproducibility and intersystem comparisons. Advancing toward quantitative imaging requires a radiometric characterization framework that provides SI-traceable units while explicitly addressing the interdependent factors that govern image formation. Aim: Establish and evaluate a radiometric characterization framework that converts device-native counts to SI-traceable imaged radiance (µW·cm −2 ·sr -1 ) and aggregate fluorescence yield (sr -1 ) while accounting for interdependent factors that influence fluorescence image formation. Approach: A calibrated Lambertian solid-state radiometric emitter target (RET) was combined with a three-step radiometric framework consisting of the Radiance Transfer Curve (RTC), the Radiance Imaging Transform (RIT), and the Fluorescence Imaging Transform (FIT). The RTC establishes system responsivity as a function of radiance; the RIT applies this calibration at the pixel level to map digital counts to SI-traceable radiance; and the FIT performs pixel-wise excitation normalization of the RIT image to produce an aggregate fluorescence yield image. The framework was tested through distance and aperture invariance, digital-vs-physical ROI analyses, RTC acquisition, and application of the RIT and FIT to an ICG concentration target and a breast lumpectomy phantom. Results: The RET exhibited Lambertian behavior, with no significant dependence of the measured radiance on distance or aperture; imager responsivity ( R λ ) also remained invariant within uncertainty across working distances and f-numbers. Digitally masked ROIs reproduced R λ obtained with matched physical apertures, enabling ROI and pixel-level radiance transfer. RTCs acquired over 49 radiances captured sensor and processing nonlinearities. The RIT provided a per-pixel mapping from counts to radiance (µW·cm −2 ·sr −1 ). Applying pipeline-specific RTCs, the RIT and FIT reconciled large discrepancies across RAW, 8-bit, and log10 image processing pipelines, yielding closely aligned radiance-concentration curves and improved SBR/SNR/CNR agreement. In a breast lumpectomy phantom, FIT produced SI-traceable aggregate fluorescence yield (sr −1 ) images and absolute contrast metrics in an anthropomorphic geometry. Conclusions: The combined framework converts device-native counts into SI-traceable radiance and aggregate fluorescence yield at the pixel level, providing a practical basis for reproducible quantitative fluorescence imaging. The feasibility results across distance/aperture tests, ROI analyses, image pipelines, and phantom imaging indicate readiness for broader evaluation. Future work will establish formal uncertainty budgets and assess robustness across devices, geometries, and excitation conditions to support adoption as a quantitative reporting standard.


  • Open Access

    Indocyanine green excitation-emission matrix characterization: excitation-dependent emission shifts and application-specific spectra

    by Alberto J. Ruiz, Sophie A. Lyon, Ethan P.M. LaRochelle, Kimberley S. Samkoe

    Significance: Indocyanine green (ICG) is the most widely used fluorophore in fluorescence-guided surgery (FGS), yet its spectral response depends on microenvironment, with implications for system design, inter-system comparisons, and phantom development. Aim: To characterize ICG with excitation–emission matrices (EEMs) in the microenvironments of dimethyl sulfoxide (DMSO), bovine serum albumin (BSA) solutions, and 3D-printed (3DP) resin, and assess excitation-dependent emission, including red-edge excitation shifts (REES) and departures from Kasha’s rule of excitation-independent emission. Approach: EEMs and absorbance spectra were acquired with extracted excitation spectra, emission spectra, emission peaks, centroids, and integrated emission areas under the curve (AUCs). Concentration-dependent behavior was examined in DMSO, and albumin concentration dependence was assessed from 5–100 mg/mL. Data processing employed robust local regression to mitigate excitation scattering artifacts. Results: ICG in DMSO exhibited excitation-independent emission consistent with Kasha–Vavilov behavior. In contrast, ICG in BSA solution and 3DP resin displayed excitation-dependent emission with pronounced REES and additional non-linear departures from Kasha’s rule. To our knowledge, this represents the first documentation of REES and broader anti-Kasha effects for ICG or any FGS fluorophore. Within the excitation range most relevant to ICG-FGS (∼760–805 nm), emission spectra of the BSA solution and 3DP resin overlapped closely, with similar AUC-based comparisons, suggesting that ICG in 3DP resin can serve as a suitable surrogate reference for albumin-bound ICG. Conclusions: The EEM characterization shows that excitation-dependent behavior is a defining feature of ICG in biologically relevant environments, demonstrating that emission cannot be assumed to follow classical Kasha–Vavilov behavior. Reliable comparisons and imaging system design therefore require spectra acquired at defined excitation wavelengths with AUC integration within the emission detection band. Excitation-specific spectra from EEMs establish a consistent framework for inter-system comparisons and phantom standards, while the resulting datasets provide a practical reference for addressing excitation-dependent behavior in ICG sensing applications.

  • Open Access

    Phantom for fluorescence uniformity and distortion assessment of near-infrared fluorescence guided surgery systems

    by Emmanuel A. Mannoh, Edwin A. Robledo, Samuel S. Streeter, Ethan P. M. LaRochelle, Alberto J. Ruiz

    SignificanceThe expanding use of fluorescence in surgery necessitates standardized characterization methods to facilitate reproducibility and regulatory review of imaging devices. Current guidelines suggest the use of optical phantoms as tools to quantify optical system performance, yet measurements of uniformity and spatial accuracy or distortion remain challenging and are performed in an ad hoc manner or not collected at all.AimWe introduce a photostable solid phantom, the reference uniformity and distortion (RUD) phantom, and accompanying analysis code for characterizing fluorescence uniformity and geometric distortion (GD). In addition, the concept of fluorescence flat-field correction is explored using this phantom.ApproachThe RUD phantom was imaged on a custom fluorescence imaging device, as well as five commercial systems. The analysis code characterized uniformity and distortion in these systems. Flat-field correction was explored on the custom device by imaging solid fluorescent reference phantoms at different locations within the field of view.ResultsSuccessful characterization of the imaging systems’ uniformity and GD was achieved. Flat-fielding experiments showed that although it qualitatively improves the appearance of images, it could negatively impact quantitative analyses.ConclusionsThe RUD addresses the need for standardized characterization of fluorescence uniformity and GD. Although fluorescence flat-field correction qualitatively enhances image uniformity, caution is advised as it may adversely affect quantitative accuracy.


  • Open Access

    Toward fluorescence digital twins: multi-parameter experimental validation of fluorescence Monte Carlo simulations using solid phantoms

    by Mayna H. Nguyen, Ethan P. M. LaRochelle, Edwin A. Robledo, Alberto J. Ruiz

    Monte Carlo modeling software provides a computational method to simulate light transport through tissue. Various Monte Carlo tools have been developed over the last few decades, utilizing statistical methods well-suited for complex geometries commonly observed in biomedical applications, where analytical solutions are not feasible. Monte Carlo simulations can provide precise predictions of light propagation, supporting numerous innovations in medical imaging, diagnostics, and therapeutic interventions. Various Monte Carlo implementations have emerged to meet diverse research and clinical needs, evolving alongside technology advancements. Early central processing unit (CPU)-based tools, such as Monte Carlo for multi-layered media (MCML),1 laid the groundwork for tissue modeling, whereas user-friendly platforms such as MCMatlab2 offer flexibility and accessibility for researchers. Commercial software, such as TracePro,3 integrates Monte Carlo methods with computer-aided design (CAD)-based optical modeling, enabling advanced simulations of light in complex systems. More recently, open-source graphics processing unit (GPU)-accelerated frameworks such as Monte Carlo eXtreme (MCX) and mesh-based Monte Carlo (MMC) have drastically improved computational efficiency, allowing fast simulations of high photon counts in three-dimensional models.4,5


  • Open Access

    A Phantom for Fluorescence Uniformity and Distortion Assessment of Near-Infrared Fluorescence Guided Surgery Systems

    by Emmanuel A. Mannoh, Edwin A. Robledo, Samuel S. Streeter, Ethan P. M. LaRochelle, Alberto J. Ruiz

    Significance The expanding use of fluorescence in surgery necessitates standardized characterization methods to facilitate reproducibility and regulatory review of imaging devices. Current guidelines suggest the use of optical phantoms as tools to quantify optical system performance, yet measurements of uniformity and spatial accuracy or distortion remain challenging and are performed in an ad hoc manner or not collected at all. Aim This work introduces a photostable solid phantom, the Reference Uniformity and Distortion (RUD) phantom, and accompanying analysis code for characterizing fluorescence uniformity and geometric distortion. Additionally, the concept of fluorescence flat-field correction is explored using this phantom. Approach The RUD phantom was imaged on a custom fluorescence imaging device, as well as five commercial systems. The analysis code characterized uniformity and distortion in these systems. Flat-field correction was explored on the custom device by imaging solid fluorescent reference phantoms at different locations within the field of view. Results Successful characterization of the imaging systems’ uniformity and geometric distortion was achieved. Flat-fielding experiments showed that while it qualitatively improves the appearance of images, it could negatively impact quantitative analyses. Conclusions The RUD addresses the need for standardized characterization of fluorescence uniformity and geometric distortion. While fluorescence flat-field correction qualitatively enhances image uniformity, caution is advised as it may adversely affect quantitative accuracy.

  • Open Access

    Assessment of open-field fluorescence guided surgery systems: implementing a standardized method for characterization and comparison

    by Marien I. Ochoa, Alberto Ruiz, Ethan LaRochelle, Matthew Reed, Eren Berber, George Poultsides, Brian W. Pogue

    Fluorescence guided surgery (FGS) has demonstrated improvements in surgical decision making and assessment of tissue function in real time for indicated procedures.1,2 Not only does fluorescence guidance provide a high level of structural perfusion accuracy in reconstruction cases, but it could also allow for molecular characterization of healthy versus diseased tissues in real time in future approved indications.3 The field evolved out of many decades of retinal flow imaging with indocyanine green (ICG) and started into bulk tissue perfusion imaging with 510(k) clearance of the SPY SP2000 FGS system through the United States Food and Drug administration (FDA) process.4 Since then, multiple FGS devices have been similarly cleared for use in open and laparoscopic surgery. The design of FGS devices is developed together with contrast agents, although advances in each are usually separated by their regulatory approvals. Despite the rapid growth5 – 7 in the use of fluorescence devices among surgeons and advances in contrast agents and FGS devices, there has been a lack of development of standardization methods within the field, and a recent consensus paper has called for improvement in this situation.8 This study examines these recommendations by implementing the suggested FGS assessment metrics for analysis of several of the leading commercial instruments.


  • Open Access

    Smartphone-based dual radiometric fluorescence and white-light imager for quantification of protoporphyrin IX in skin

    by Alberto J. Ruiz, Richard Allen, Mia K. Giallorenzi, Kimberley S. Samkoe, M. Shane Chapman, Brian W. Pogue

    The detection and quantification of protoporphyrin IX (PpIX) is an important diagnostic tool in various medical fields, including dermatology and oncology.1 – 3 Within dermatology, PpIX-based skin photodynamic therapy (PDT) is increasingly used for the clinical treatment of actinic keratosis (AK) lesions, replacing traditional cryosurgery, chemical peel, and curettage treatments.4,5 Despite the widespread clinical use of skin PDT, the primary treatment outcome of AK lesion clearance rates varies widely, which is primarily caused by heterogeneous accumulation of the photosensitizer PpIX between patients and between lesions.6,7 Furthermore, the presence and accumulation of PpIX in skin is also related to conditions like porphyria8,9 and can be used for the preoperative mapping of non-melanoma skin cancers.10,11 Therefore, the ability to visualize and quantify skin PpIX in clinical settings can be used to help guide critical decisions at the point-of-care, including mitigative actions to improve patient outcomes. Imaging and spectroscopy techniques have shown potential for PpIX quantification, with fluorescence (FL) imaging techniques demonstrating great promise for non-invasive measurement of PpIX in the skin.6,12 Additionally, smartphone-based imaging (SBI) devices have emerged as a promising approach for PpIX quantification, offering cost-effective solutions that could be integrated into the clinical workflow.13 – 15