Clarke A. Hardy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Clarke A. Hardy has a total of 709 co-authors. Here are the top co-authors by number of shared publications:
- Carl Eric Dahl
Northwestern Univ., Evanston, IL (United States)
4 shared publications J. Farine
4 shared publicationsA. E. Robinson
Département de Physique, Université de Montréal, Montréal, H3C 3J7, Canada
3 shared publicationsA. J. Noble
Department of Physics, Queen’s University, Kingston, K7L 3N6, Canada
3 shared publicationsA. Leblanc
Department of Physics, Laurentian University, Sudbury, P3E 2C6, Canada
3 shared publicationsA. Ortega
Enrico Fermi Institute, KICP and Department of Physics, University of Chicago, Chicago, IL, 60637, USA
3 shared publications
Latest Publications
- 19 October 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (17) , 173601
Optomechanical Detection of Individual Gas Collisions
An experiment resolves the tiny momentum transferred from an individual gas molecule to a levitated nanoparticle.
- 19 October 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (17) , 173601
Optomechanical Detection of Individual Gas Collisions
An experiment resolves the tiny momentum transferred from an individual gas molecule to a levitated nanoparticle.
- Open Access
- 13 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Optomechanical vector sensing of new forces at 6 micron separation
The search for new gravity-like interactions at the sub-millimeter scale is a compelling area of research, with important implications for the understanding of classical gravity and its connections with quantum physics. We report improved constraints on Yukawa-type interactions in the $$10\,\mathrm {\mu m}$$ regime using optically levitated dielectric microspheres as test masses. The search is performed, for the first time, sensing multiple spatial components of the force vector, and with sensitivity improved by a factor of $$\sim 100$$ with respect to previous measurements using the same technique. The resulting upper limit on the strength of a hypothetical new force is $$10^7$$ at a Yukawa range $$\lambda \simeq 5\;\mu$$ m and close to $$10^6$$ for $$\lambda \gtrsim 10\;\mu$$ m. This result also advances our efforts to measure gravitational effects using micrometer-size objects, with important implications for embryonic ideas to investigate the quantum nature of gravity.- 13 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessOptomechanical vector sensing of new forces at 6 micron separation
The search for new gravity-like interactions at the sub-millimeter scale is a compelling area of research, with important implications for the understanding of classical gravity and its connections with quantum physics. We report improved constraints on Yukawa-type interactions in the $$10\,\mathrm {\mu m}$$ regime using optically levitated dielectric microspheres as test masses. The search is performed, for the first time, sensing multiple spatial components of the force vector, and with sensitivity improved by a factor of $$\sim 100$$ with respect to previous measurements using the same technique. The resulting upper limit on the strength of a hypothetical new force is $$10^7$$ at a Yukawa range $$\lambda \simeq 5\;\mu$$ m and close to $$10^6$$ for $$\lambda \gtrsim 10\;\mu$$ m. This result also advances our efforts to measure gravitational effects using micrometer-size objects, with important implications for embryonic ideas to investigate the quantum nature of gravity. - 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11005
A flexible test facility for liquid xenon detector development
As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. We describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11005
A flexible test facility for liquid xenon detector development
As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. We describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.
- Open Access
- 15 July 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (1)
Electron-ion recombination in composite interactions in liquid xenon
The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.
- 15 July 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (1)
Open AccessElectron-ion recombination in composite interactions in liquid xenon
The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.
- Open Access
- 4 September 2020
- Published by Springer Nature in The European Physical Journal C
- Vol. 80 (9) , 1-8
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 $$\hbox {C}_3\hbox {F}_8$$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (JCAP 1509: 052, 2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $$\sigma _{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm {cm}^2$$ ( $$6 \times 10^{-38} \mathrm {cm}^2$$ ) at $$\gtrsim 90\%$$ C.L. for a DM particle of mass 1 TeV annihilating into $$\tau ^+ \tau ^-$$ ( $$b\bar{b}$$ ) with a local density of $$\rho _{\mathrm{DM}} = 0.3~\mathrm {GeV/cm}^3$$ . The constraints scale inversely with $$\rho _{\mathrm{DM}}$$ and are independent of the DM velocity distribution.- 4 September 2020
- Published by Springer Nature in The European Physical Journal C
- Vol. 80 (9) , 1-8
Open AccessVelocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 $$\hbox {C}_3\hbox {F}_8$$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (JCAP 1509: 052, 2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $$\sigma _{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm {cm}^2$$ ( $$6 \times 10^{-38} \mathrm {cm}^2$$ ) at $$\gtrsim 90\%$$ C.L. for a DM particle of mass 1 TeV annihilating into $$\tau ^+ \tau ^-$$ ( $$b\bar{b}$$ ) with a local density of $$\rho _{\mathrm{DM}} = 0.3~\mathrm {GeV/cm}^3$$ . The constraints scale inversely with $$\rho _{\mathrm{DM}}$$ and are independent of the DM velocity distribution. - 31 October 2019
- Published by American Physical Society (APS) in Physical Review D
- Vol. 100 (8) , 082006
Data-driven modeling of electron recoil nucleation in PICO bubble chambersThe primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to .- 31 October 2019
- Published by American Physical Society (APS) in Physical Review D
- Vol. 100 (8) , 082006
Data-driven modeling of electron recoil nucleation in PICO bubble chambersThe primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to .- Top Cited Papers
- 9 July 2019
- Published by American Physical Society (APS) in Physical Review D
- Vol. 100 (2) , 022001
Dark matter search results from the complete exposure of the PICO-60 bubble chamberFinal results are reported from operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.- 9 July 2019
- Published by American Physical Society (APS) in Physical Review D
- Vol. 100 (2) , 022001
Top Cited PapersDark matter search results from the complete exposure of the PICO-60 bubble chamberFinal results are reported from operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.