Syed Fariq Fathullah Syed Yaacob
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Syed Fariq Fathullah Syed Yaacob has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Faiz Bukhari Mohd Suah
Universiti Sains Malaysia
3 shared publications - Arniza Khairani Mohd Jamil
Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications Muhammad Afzal Kamboh
Department of Chemistry, Shaheed Benazir Bhutto University, Shaheed Benazirabad, Sindh, Pakistan
2 shared publicationsSharifah Mohamad
2 shared publications- Sharifah Mohamad
Department of Chemistry, Faculty of Science, University of Malaya, Lembah Pantai 50603, Kuala Lumpur, Malaysia
2 shared publications Wan Aini Wan Ibrahim
Separation Science and Technology Group (SepSTec), Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia
2 shared publications
Latest Publications
- 21 May 2024
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 60 (5) , 392-399
Ascorbic Acid Sensor Using Modified Pencil Graphite Electrodes: A Preliminary Study
This study aimed to develop an electrochemical sensor based on a derivative of graphene oxide (GO) and a molecularly imprinted polymer (MIP) on a pencil graphite electrode (PGE) for the detection of ascorbic acid (AA). MIP was fabricated onto the surface of the electrode by electropolymerization technique using cyclic voltammetry with a scan rate of 10 mV/s consisting of template molecule (ascorbic acid), functional monomer (polypyrrole), cross-linker (LiClO4) and citrate buffer at pH 4. Then, the template removal process was conducted to create the imprinted cavities for detecting the analyte. Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) methods were used to perform quantitative analyses of the modified electrodes. CV analysis was performed at the optimum scan rate of 10 mV/s, and the electrolyte concentration at 1.0 mM K3[Fe(CN)6] in 0.1 M KCl. MIP-PGE (2) produced the best performance by having the highest redox peak current response when scanning with the CV compared to other modified electrodes. The optimum parameters for DPV measurement are 100 mV pulse amplitude, 200 ms pulse period, and 10 mV/s scan rate. The straightforward instrumentation and easy preparation of the proposed sensor make it a valuable system for constructing simple devices for determining ascorbic acid.
- 21 May 2024
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 60 (5) , 392-399
Ascorbic Acid Sensor Using Modified Pencil Graphite Electrodes: A Preliminary Study
This study aimed to develop an electrochemical sensor based on a derivative of graphene oxide (GO) and a molecularly imprinted polymer (MIP) on a pencil graphite electrode (PGE) for the detection of ascorbic acid (AA). MIP was fabricated onto the surface of the electrode by electropolymerization technique using cyclic voltammetry with a scan rate of 10 mV/s consisting of template molecule (ascorbic acid), functional monomer (polypyrrole), cross-linker (LiClO4) and citrate buffer at pH 4. Then, the template removal process was conducted to create the imprinted cavities for detecting the analyte. Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) methods were used to perform quantitative analyses of the modified electrodes. CV analysis was performed at the optimum scan rate of 10 mV/s, and the electrolyte concentration at 1.0 mM K3[Fe(CN)6] in 0.1 M KCl. MIP-PGE (2) produced the best performance by having the highest redox peak current response when scanning with the CV compared to other modified electrodes. The optimum parameters for DPV measurement are 100 mV pulse amplitude, 200 ms pulse period, and 10 mV/s scan rate. The straightforward instrumentation and easy preparation of the proposed sensor make it a valuable system for constructing simple devices for determining ascorbic acid.
- Open Access
- 27 August 2023
- Published by Penerbit UTM Press in Malaysian Journal of Fundamental and Applied Sciences
- Vol. 19 (4) , 471-480
Electrogenerative Process as an Alternate Technique for Nickel Recovery from Its Sulphate Solution at Low Concentration
In this study, a static batch reactor equipped with three-dimensional (3-D) carbon felt (CF) as cathode material was fully optimized to recover a low nickel concentration from its sulphate solution. Nickel recovery was performed using several nickel concentrations ranging from 50, 100, 250, 400 and 500 mg/L. Moreover, within 30 min of electrogenerative operation, it was discovered that the recovery of nickel achieved > 90 % in acidic conditions. At last, the deposition of nickel into CF was further investigated by scanning electron microscopy (SEM) to visualize the surface morphology of nickel on CF.
- 27 August 2023
- Published by Penerbit UTM Press in Malaysian Journal of Fundamental and Applied Sciences
- Vol. 19 (4) , 471-480
Open AccessElectrogenerative Process as an Alternate Technique for Nickel Recovery from Its Sulphate Solution at Low Concentration
In this study, a static batch reactor equipped with three-dimensional (3-D) carbon felt (CF) as cathode material was fully optimized to recover a low nickel concentration from its sulphate solution. Nickel recovery was performed using several nickel concentrations ranging from 50, 100, 250, 400 and 500 mg/L. Moreover, within 30 min of electrogenerative operation, it was discovered that the recovery of nickel achieved > 90 % in acidic conditions. At last, the deposition of nickel into CF was further investigated by scanning electron microscopy (SEM) to visualize the surface morphology of nickel on CF.
- Open Access
- 8 December 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
Hybrid polymer inclusion membrane as anion exchange membrane for recovering Pd2+ ions in electrogenerative process
A novel non-plasticized nano-porous hybrid inorganic-organic polymer inclusion membrane (PIM) was synthesized, characterized, and evaluated as an anion exchange membrane for application in electrogenerative processes to recover Pd2+ ions. Ionic liquids 1-ethyl-3-methylimidazolium chloride (EMIM-Cl) and 1-butyl-3-methylimidazolium chloride (BMIM-Cl) were used as the carrier molecules in the polymeric network of PIM to enhance anion exchange process. This hybrid anion exchange membrane also consists of a polymeric matrix of non-plasticized cellulose triacetate modified by incorporating an inorganic material (silane) prepared by the sol-gel route. Different parameters affecting the ion transport performance efficiency, i.e., the composition of the membrane, type of ionic liquid (carrier molecule) and ion–exchange capacity, were investigated and optimized. In the electrogenerative process, the results revealed that the prepared PIM yields better recovery results for recovering Pd2+ ions from its chloride solution compared to the commercial anion exchange membrane Neosepta® AM-01, with a full recovery of 100 mg/L Pd2+ ions in 30 min. This preliminary study shows that the prepared low-cost hybrid anion exchange membrane PIM can act as an inexpensive material suitable for the rapid and efficient recovery of Pd2+ ions from an aqueous solution.
- 8 December 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
Open AccessHybrid polymer inclusion membrane as anion exchange membrane for recovering Pd2+ ions in electrogenerative process
A novel non-plasticized nano-porous hybrid inorganic-organic polymer inclusion membrane (PIM) was synthesized, characterized, and evaluated as an anion exchange membrane for application in electrogenerative processes to recover Pd2+ ions. Ionic liquids 1-ethyl-3-methylimidazolium chloride (EMIM-Cl) and 1-butyl-3-methylimidazolium chloride (BMIM-Cl) were used as the carrier molecules in the polymeric network of PIM to enhance anion exchange process. This hybrid anion exchange membrane also consists of a polymeric matrix of non-plasticized cellulose triacetate modified by incorporating an inorganic material (silane) prepared by the sol-gel route. Different parameters affecting the ion transport performance efficiency, i.e., the composition of the membrane, type of ionic liquid (carrier molecule) and ion–exchange capacity, were investigated and optimized. In the electrogenerative process, the results revealed that the prepared PIM yields better recovery results for recovering Pd2+ ions from its chloride solution compared to the commercial anion exchange membrane Neosepta® AM-01, with a full recovery of 100 mg/L Pd2+ ions in 30 min. This preliminary study shows that the prepared low-cost hybrid anion exchange membrane PIM can act as an inexpensive material suitable for the rapid and efficient recovery of Pd2+ ions from an aqueous solution.
- 4 April 2022
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 207, 990-1004
Sporopollenin based materials as a versatile choice for the detoxification of environmental pollutants — A review
- 4 April 2022
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 207, 990-1004
Sporopollenin based materials as a versatile choice for the detoxification of environmental pollutants — A review
- 1 November 2018
- Published by Elsevier in Industrial Crops and Products
- Vol. 124, 442-448
Synthesis and characterizations of magnetic bio-material sporopollenin for the removal of oil from aqueous environment
- 1 November 2018
- Published by Elsevier in Industrial Crops and Products
- Vol. 124, 442-448
Synthesis and characterizations of magnetic bio-material sporopollenin for the removal of oil from aqueous environment
- Open Access
- 18 July 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (7) , 171311
New sporopollenin-based β-cyclodextrin functionalized magnetic hybrid adsorbent for magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs from water samples
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized magnetic β-cyclodextrin functionalized with toluene diisocyanate (TDI) as a linker and further modified with bio-polymeric spores of sporopollenin (MSp-TDI-βCD), was developed for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs), namely, indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP) from water samples prior to their HPLC-DAD determination. The newly synthesized MSp-TDI-βCD was comprehensibly characterized using FT-IR, XRD, SEM-EDX, BET and VSM analyses. The separation of selected NSAIDs on MSp-TDI-βCD from aqueous solution was simply achieved by applying an external magnetic field via a permanent magnet. The MSPE parameters affecting extraction performance, i.e. sorbent dosage, sample volume, extraction and desorption time, type of organic eluent and volume and solution pH were investigated and optimized. The proposed method showed linear range between 0.5 and 500 ng ml −1 , low limit of detection at S/N = 3 (0.16–0.37 ng ml −1 ) and limit of quantification at S/N = 10 (0.53–1.22 ng ml −1 ). The inter-day ( n = 15) and intra-day ( n = 5) precision for the proposed methods given by relative standard deviation (RSD%) was in the range of 2.5–4.0 and 2.1–5.5, respectively. The extraction recoveries of NSAIDs from environmental samples (tap, drinking and river water) ranged from 92.5% to 123.6%, with satisfactory precision (RSD% less than 12.4%).
- 18 July 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (7) , 171311
Open AccessNew sporopollenin-based β-cyclodextrin functionalized magnetic hybrid adsorbent for magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs from water samples
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized magnetic β-cyclodextrin functionalized with toluene diisocyanate (TDI) as a linker and further modified with bio-polymeric spores of sporopollenin (MSp-TDI-βCD), was developed for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs), namely, indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP) from water samples prior to their HPLC-DAD determination. The newly synthesized MSp-TDI-βCD was comprehensibly characterized using FT-IR, XRD, SEM-EDX, BET and VSM analyses. The separation of selected NSAIDs on MSp-TDI-βCD from aqueous solution was simply achieved by applying an external magnetic field via a permanent magnet. The MSPE parameters affecting extraction performance, i.e. sorbent dosage, sample volume, extraction and desorption time, type of organic eluent and volume and solution pH were investigated and optimized. The proposed method showed linear range between 0.5 and 500 ng ml −1 , low limit of detection at S/N = 3 (0.16–0.37 ng ml −1 ) and limit of quantification at S/N = 10 (0.53–1.22 ng ml −1 ). The inter-day ( n = 15) and intra-day ( n = 5) precision for the proposed methods given by relative standard deviation (RSD%) was in the range of 2.5–4.0 and 2.1–5.5, respectively. The extraction recoveries of NSAIDs from environmental samples (tap, drinking and river water) ranged from 92.5% to 123.6%, with satisfactory precision (RSD% less than 12.4%).
- Open Access
Fabrication of calixarene-grafted bio-polymeric magnetic composites for magnetic solid phase extraction of non-steroidal anti-inflammatory drugs in water samples
Calixarene framework functionalized bio-polymeric magnetic composites (MSp-TDI-calix) were synthesized and utilized as magnetic solid-phase extraction (MSPE) sorbent for the extraction of non-steroidal anti-inflammatory drugs (NSAIDs), namely indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP), from environmental water samples. MSp-TDI-calix was characterized by FT-IR, XRD, FESEM, EDX, VSM and BET analysis, and the results were compared with Sp-TDI and Sp-TDI-calix. To maximize the extraction performance of MSp-TDI-calix decisive MSPE affective parameters such as sorbent amount, extraction time, sample volume, type of organic eluent, volume of organic eluent, desorption time and pH were comprehensively optimized prior to HPLC-DAD determination. The analytical validity of the proposed MSPE method was evaluated under optimized conditions and the following figures of merit were acquired: linearity with good determination coefficient (R2 ≥ 0.991) over the concentration range of 0.5–500 µg/L, limits of detection (LODs) ranged from 0.06–0.26 µg/L and limits of quantitation (LOQ) between 0.20–0.89 µg/L. Excellent reproducibility and repeatability under harsh environment with inter-day and intra-day relative standard deviations were obtained in the range of 2.5–3.2% and 2.4–3.9% respectively. The proposed method was successfully applied for analysis of NSAIDs in tap water, drinking water and river water with recovery efficiency ranging from 88.1–115.8% with %RSD of 1.6–4.6%.
Open AccessFabrication of calixarene-grafted bio-polymeric magnetic composites for magnetic solid phase extraction of non-steroidal anti-inflammatory drugs in water samples
Calixarene framework functionalized bio-polymeric magnetic composites (MSp-TDI-calix) were synthesized and utilized as magnetic solid-phase extraction (MSPE) sorbent for the extraction of non-steroidal anti-inflammatory drugs (NSAIDs), namely indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP), from environmental water samples. MSp-TDI-calix was characterized by FT-IR, XRD, FESEM, EDX, VSM and BET analysis, and the results were compared with Sp-TDI and Sp-TDI-calix. To maximize the extraction performance of MSp-TDI-calix decisive MSPE affective parameters such as sorbent amount, extraction time, sample volume, type of organic eluent, volume of organic eluent, desorption time and pH were comprehensively optimized prior to HPLC-DAD determination. The analytical validity of the proposed MSPE method was evaluated under optimized conditions and the following figures of merit were acquired: linearity with good determination coefficient (R2 ≥ 0.991) over the concentration range of 0.5–500 µg/L, limits of detection (LODs) ranged from 0.06–0.26 µg/L and limits of quantitation (LOQ) between 0.20–0.89 µg/L. Excellent reproducibility and repeatability under harsh environment with inter-day and intra-day relative standard deviations were obtained in the range of 2.5–3.2% and 2.4–3.9% respectively. The proposed method was successfully applied for analysis of NSAIDs in tap water, drinking water and river water with recovery efficiency ranging from 88.1–115.8% with %RSD of 1.6–4.6%.
- 1 December 2015
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 212, 850-856
Supramolecular interaction of 2,4-dichlorophenol and β-cyclodextrin functionalized ionic liquid and its preliminary study in sensor application
- 1 December 2015
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 212, 850-856
Supramolecular interaction of 2,4-dichlorophenol and β-cyclodextrin functionalized ionic liquid and its preliminary study in sensor application