Douglas Voss de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Douglas Voss de Oliveira has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- José Thiers Carneiro
Universidade Federal do Pará, Brazil
6 shared publications - Nayara Cristina Monteiro Carneiro
Federal University of Pará, Augusto Corrêa, 01, Guamá, CEP: 66075-110, Belém, PA, Brazil
2 shared publications - Alvaro Della Bona
Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
1 shared publication - Ana Karla da Silva Tabosa
Oral and Maxillofacial Surgery - Brazilian Dental Association, Augusto Corrêa, 01, Guamá. CEP, 66075-110, Belém, PA, Brazil; Master Student in Oral and Maxillofacial Surgery - Federal University of Pará, Augusto Corrêa, 01, Guamá. CEP, 66075-110, Belém, PA, Brazil
1 shared publication - David Normando
Departament of Orthodontics, Faculty of Dentistry, Universidade Federal do Pará, Belém, Brazil
1 shared publication - Diogo Souza Ferreira Rubim de Assis
Universidade Federal do Maranhão. Faculdade de Odontologia. Departamento de Morfologia. Professor
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- p. 1-9
Is it Possible to Obtain a Predictive Model for Occlusal Stability in Surgery First Orthognathic Surgery? An Exploratory Hypothesis-Generating Study
Orthognathic surgery is a surgical procedure for repositioning the maxillomandibular bone bases in patients with dento-skeletal discrepancies. “Surgery First” philosophy is a challenging approach for breaking paradigms through relativization regarding occlusal determinism for stability. The aim of this study was to analyze the trend of predictive occlusal stability in 36 Amazonian patients and candidates for orthognathic “Surgery First”. The variables gender, age, etiology, existence of orthodontic intervention, number of teeth, surgical movements, number of total contacts, their distribution by segment and intensity were considered. For this, medical records and virtual models made available by the Arch Vertical Collision Map tool of the Dolphin Imaging software were analyzed after the virtual planning was completed. Data were tabulated and processed in Bioestat 5.0 software (Mamirauá Institute). The sample consisted of individuals with a mean age of 36 years and a mean number of teeth of 28 elements; 81% did not undergo any orthodontic intervention prior to surgery. It was not possible to predict the number and intensity of occlusal contacts according to the type of surgical movement and etiology. Orthodontic intervention in the mandible, even if minimal, has the potential to influence postoperative stability and provide less intense contacts; the number of teeth is not an isolated predictor of stability.
- 23 October 2026
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- p. 1-9
Open AccessIs it Possible to Obtain a Predictive Model for Occlusal Stability in Surgery First Orthognathic Surgery? An Exploratory Hypothesis-Generating Study
Orthognathic surgery is a surgical procedure for repositioning the maxillomandibular bone bases in patients with dento-skeletal discrepancies. “Surgery First” philosophy is a challenging approach for breaking paradigms through relativization regarding occlusal determinism for stability. The aim of this study was to analyze the trend of predictive occlusal stability in 36 Amazonian patients and candidates for orthognathic “Surgery First”. The variables gender, age, etiology, existence of orthodontic intervention, number of teeth, surgical movements, number of total contacts, their distribution by segment and intensity were considered. For this, medical records and virtual models made available by the Arch Vertical Collision Map tool of the Dolphin Imaging software were analyzed after the virtual planning was completed. Data were tabulated and processed in Bioestat 5.0 software (Mamirauá Institute). The sample consisted of individuals with a mean age of 36 years and a mean number of teeth of 28 elements; 81% did not undergo any orthodontic intervention prior to surgery. It was not possible to predict the number and intensity of occlusal contacts according to the type of surgical movement and etiology. Orthodontic intervention in the mandible, even if minimal, has the potential to influence postoperative stability and provide less intense contacts; the number of teeth is not an isolated predictor of stability.
- 6 April 2025
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 53 (7) , 1018-1023
Compare the accuracy and performance of two different types of CAD-CAM surgical guides for maxillary positioning in orthognathic surgery
- 6 April 2025
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 53 (7) , 1018-1023
Compare the accuracy and performance of two different types of CAD-CAM surgical guides for maxillary positioning in orthognathic surgery
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24230307
A CAD/CAM Maxillary Guiding for Osteotomy, Drilling and Maxillary Positioning in Orthognathic Surgery: Accuracy Analysis.
Resin CAD/CAM guides for the maxilla are widely used and differ from custom miniplates essentially in that they do not have drill guides for screw fixation and use miniplates that must be modeled in surgery. To solve this problem, we have developed a new Maxillary guide bone-supported indicated for osteotomy, drilling, and maxillary positioning in orthognathic surgeries using standard modeled miniplates. In this study were included sixteen patients who had bimaxillary orthognathic surgery. The technique for its manufacturing is described, and its surgical accuracy was analyzed using the planning image (CT0) superimposed on the computed tomography scan post-treatment (CT1). The mean positional differences between pre-treatment and post-treatment were obtained Tri-dimensionally on the X, Y, and Z axes using four landmarks points: one bone (SNA), and three dentals (CI, RM, and LM). At Sixty-four points analyzed on the X axis of the four landmarks, only eight points were greater than 1 mm; 87.5 % of the deviations were <1 mm. For the Y-axis 78.12% of the deviations were <1 mm and for Z-axis, 76.56 %. The mean and standard deviation of the error was 0.36 (0.28) mm, 0.93 (1.07) mm, and 0.73 (0.86) mm on the X, Y, and Z axes, respectively. The X-axis demonstrated the best results among the three axes. The results of the accuracy and reliability tests were satisfactory and support the use of the proposed technique.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24230307
Open AccessA CAD/CAM Maxillary Guiding for Osteotomy, Drilling and Maxillary Positioning in Orthognathic Surgery: Accuracy Analysis.
Resin CAD/CAM guides for the maxilla are widely used and differ from custom miniplates essentially in that they do not have drill guides for screw fixation and use miniplates that must be modeled in surgery. To solve this problem, we have developed a new Maxillary guide bone-supported indicated for osteotomy, drilling, and maxillary positioning in orthognathic surgeries using standard modeled miniplates. In this study were included sixteen patients who had bimaxillary orthognathic surgery. The technique for its manufacturing is described, and its surgical accuracy was analyzed using the planning image (CT0) superimposed on the computed tomography scan post-treatment (CT1). The mean positional differences between pre-treatment and post-treatment were obtained Tri-dimensionally on the X, Y, and Z axes using four landmarks points: one bone (SNA), and three dentals (CI, RM, and LM). At Sixty-four points analyzed on the X axis of the four landmarks, only eight points were greater than 1 mm; 87.5 % of the deviations were <1 mm. For the Y-axis 78.12% of the deviations were <1 mm and for Z-axis, 76.56 %. The mean and standard deviation of the error was 0.36 (0.28) mm, 0.93 (1.07) mm, and 0.73 (0.86) mm on the X, Y, and Z axes, respectively. The X-axis demonstrated the best results among the three axes. The results of the accuracy and reliability tests were satisfactory and support the use of the proposed technique.
- 1 December 2020
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 48 (12) , 1119-1125
A new model of customized maxillary guide for orthognathic surgery: Precision analysis
- 1 December 2020
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 48 (12) , 1119-1125
A new model of customized maxillary guide for orthognathic surgery: Precision analysis
- Open Access
- 9 April 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (6) , e15963095
Ankylosed joint replacement with custom total joint prosthesis and custom miniplates.
When managing a severely ankylosed joint in a patient with a history of multiple previous operations since the development phase, it is necessary besides the total joint replacement also the orthognathic surgery. Miniplates and total joint custom-made prosthesis are the state of arts in accuracy and precision; therefore use them concurrently in a complex surgery, such this, is a suitable treatment option. A 44-year-old male patient with bilateral temporomandibular joint ankylosis where the TMJ architecture was completely replaced by a large bone mass was treated through orthognathic surgery with customized cutting guides and customized material for maxilla, jaw and chin fixation, in addition to the installation of two complete custom-made joint-prosthesis in one-stage surgery. This is the first report in the literature using custom Miniplates and Joint-Prosthesis for treatment of Ankylosis. The treatment was successful and the patient benefited from adequate aesthetics and function.
- 9 April 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (6) , e15963095
Open AccessAnkylosed joint replacement with custom total joint prosthesis and custom miniplates.
When managing a severely ankylosed joint in a patient with a history of multiple previous operations since the development phase, it is necessary besides the total joint replacement also the orthognathic surgery. Miniplates and total joint custom-made prosthesis are the state of arts in accuracy and precision; therefore use them concurrently in a complex surgery, such this, is a suitable treatment option. A 44-year-old male patient with bilateral temporomandibular joint ankylosis where the TMJ architecture was completely replaced by a large bone mass was treated through orthognathic surgery with customized cutting guides and customized material for maxilla, jaw and chin fixation, in addition to the installation of two complete custom-made joint-prosthesis in one-stage surgery. This is the first report in the literature using custom Miniplates and Joint-Prosthesis for treatment of Ankylosis. The treatment was successful and the patient benefited from adequate aesthetics and function.
- 6 June 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 46 (9) , 1448-1454
Maxillary stability following Le Fort I osteotomy using prebent plates and wire fixation in patients undergoing surgery for OSAS
- 6 June 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 46 (9) , 1448-1454
Maxillary stability following Le Fort I osteotomy using prebent plates and wire fixation in patients undergoing surgery for OSAS
- 1 May 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (5) , 1091.e1-1091.e8
Custom-Made Titanium Miniplates Associated With Ultrahigh-Molecular-Weight Polyethylene Graft in Orthognathic Surgery: An Adjunct to Maxillary Advancement
- 1 May 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (5) , 1091.e1-1091.e8
Custom-Made Titanium Miniplates Associated With Ultrahigh-Molecular-Weight Polyethylene Graft in Orthognathic Surgery: An Adjunct to Maxillary Advancement
- Open Access
- 1 July 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (4) , 421-425
Radiographic evaluation of furcal perforations sealed with different materials in dogs' teeth
The objective of this work was to evaluate, using radiographic images, the behavior of four materials used to repair root perforations in dogs' teeth. Second and third premolars of 6 dogs were used. The 48 teeth were randomly divided into 4 groups (n=12) and the perforations were sealed with one of the following materials: MTA, AH Plus, Vitremer and gutta-percha. Dogs were submitted to general anesthesia, teeth were radiographed and pulp was accessed. Perforations were done, at the maximum curve of the pulp floor, sealed and the accessed coronal cavity was filled with glass ionomer cement (Vidrion R). After 90 days, the dogs were sacrificed and the last x-ray image was taken. Images were analyzed for the presence/absence of periodontal lesions at the perforation region. Data were analyzed statistically by chi-square test at 5% significance level. There were no statistically significant differences (p≥0.05) among AH Plus, Vitremer and gutta-percha groups. MTA produced the smallest number of periodontal lesions (p<0.05). It may be concluded that none of the tested materials was able to preserve the integrity of the periodontal tissues in the furcation region, and the use of MTA resulted in the least formation of adjacent periodontal bone lesions revealed by the radiographic comparisons.
- 1 July 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (4) , 421-425
Open AccessRadiographic evaluation of furcal perforations sealed with different materials in dogs' teeth
The objective of this work was to evaluate, using radiographic images, the behavior of four materials used to repair root perforations in dogs' teeth. Second and third premolars of 6 dogs were used. The 48 teeth were randomly divided into 4 groups (n=12) and the perforations were sealed with one of the following materials: MTA, AH Plus, Vitremer and gutta-percha. Dogs were submitted to general anesthesia, teeth were radiographed and pulp was accessed. Perforations were done, at the maximum curve of the pulp floor, sealed and the accessed coronal cavity was filled with glass ionomer cement (Vidrion R). After 90 days, the dogs were sacrificed and the last x-ray image was taken. Images were analyzed for the presence/absence of periodontal lesions at the perforation region. Data were analyzed statistically by chi-square test at 5% significance level. There were no statistically significant differences (p≥0.05) among AH Plus, Vitremer and gutta-percha groups. MTA produced the smallest number of periodontal lesions (p<0.05). It may be concluded that none of the tested materials was able to preserve the integrity of the periodontal tissues in the furcation region, and the use of MTA resulted in the least formation of adjacent periodontal bone lesions revealed by the radiographic comparisons.