Michael T. Pyne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael T. Pyne has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
David R. Hillyard
Department of Pathology, University of Utah , Salt Lake City, Utah, USA
12 shared publicationsWeston C. Hymas
ARUP Laboratories , Salt Lake City, Utah, USA
4 shared publicationsAdam P. Barker
ARUP Institute for Clinical and Experimental Pathology, ARUP Laboratories , Salt Lake City, Utah, USA
2 shared publicationsAmit Phansalkar
ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, Utah 84108,1 University of Utah Department of Pathology, 15 North Medical Drive East, Salt Lake City, Utah 841122
2 shared publications- Andrew R. Wilson
Department of Family and Preventive Medicine, University of Utah, Salt Lake City, Utah, United States of America
2 shared publications - Benjamin Thomas Bradley
Department of Pathology, University of Utah
2 shared publications
Latest Publications
- 14 February 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (2) , e0127523
Repeat testing of mpox specimens with late CTs improves detection of potential false positive cases
The mpox pandemic necessitated the rapid development of clinical assays for monkeypox virus detection. While the majority of mpox specimens have high viral loads with corresponding early cycle threshold (CT) values, reports have indicated some specimens with late CT values can represent false positive results. To mitigate this risk, the Centers for Disease Control and Prevention (CDC) published an advisory recommending repeat testing of all specimens with CT values ≥34. However, limited experimental data were available to support this specific cutoff. In this study, we examine whether a more conservative approach in which all specimens with CT values ≥29 are repeated would improve the detection of potential false positive results. Compared to the CDC algorithm, our approach identified an additional 20% (5/25) of potential false positive results. To assess the impact of this cutoff on laboratory workload, we modeled the expected increase in test volume and turnaround time (TAT) relative to the CDC method. Using a lower repeat threshold, test volume increased by 0.7% while mean TAT increased by less than 15 minutes. Overall, a lower threshold than recommended by the CDC for repeating late CT mpox specimens may reduce the number of false positives reported while minimally impacting testing volume and TAT.
- 14 February 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (2) , e0127523
Repeat testing of mpox specimens with late CTs improves detection of potential false positive cases
The mpox pandemic necessitated the rapid development of clinical assays for monkeypox virus detection. While the majority of mpox specimens have high viral loads with corresponding early cycle threshold (CT) values, reports have indicated some specimens with late CT values can represent false positive results. To mitigate this risk, the Centers for Disease Control and Prevention (CDC) published an advisory recommending repeat testing of all specimens with CT values ≥34. However, limited experimental data were available to support this specific cutoff. In this study, we examine whether a more conservative approach in which all specimens with CT values ≥29 are repeated would improve the detection of potential false positive results. Compared to the CDC algorithm, our approach identified an additional 20% (5/25) of potential false positive results. To assess the impact of this cutoff on laboratory workload, we modeled the expected increase in test volume and turnaround time (TAT) relative to the CDC method. Using a lower repeat threshold, test volume increased by 0.7% while mean TAT increased by less than 15 minutes. Overall, a lower threshold than recommended by the CDC for repeating late CT mpox specimens may reduce the number of false positives reported while minimally impacting testing volume and TAT.
- 19 December 2023
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 61 (12) , e0082923
Development and validation of a next-generation sequencing assay with open-access analysis software for detecting resistance-associated mutations in CMV
Cytomegalovirus (CMV) resistance testing by targeted next-generation sequencing (NGS) allows for the simultaneous analysis of multiple genes. We developed and validated an amplicon-based Ion Torrent NGS assay to detect CMV resistance mutations in UL27, UL54, UL56, and UL97 and compared the results to standard Sanger sequencing. NGS primers were designed to generate 83 overlapping amplicons of four CMV genes (~10 kb encompassing 138 mutation sites). An open-access software plugin was developed to perform read alignment, call variants, and interpret drug resistance. Plasmids were tested to determine NGS error rate and minor variant limit of detection. NGS limit of detection was determined using the CMV WHO International Standard and quantified clinical specimens. Reproducibility was also assessed. After establishing quality control metrics, 185 patient specimens previously tested using Sanger were reanalyzed by NGS. The NGS assay had a low error rate (<0.05%) and high accuracy (95%) for detecting CMV-associated resistance mutations present at ≥5% in contrived mixed populations. Mutation sites were reproducibly sequenced with 40× coverage when plasma viral loads were ≥2.6 log IU/mL. NGS detected the same resistance-associated mutations identified by Sanger in 68/69 (98.6%) specimens. In 16 specimens, NGS detected 18 resistance mutations that Sanger failed to detect; 14 were low-frequency variants (<20%), and six would have changed the drug resistance interpretation. The NGS assay showed excellent agreement with Sanger and generated high-quality sequence from low viral load specimens. Additionally, the higher resolution and analytic sensitivity of NGS potentially enables earlier detection of antiviral resistance.
- 19 December 2023
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 61 (12) , e0082923
Development and validation of a next-generation sequencing assay with open-access analysis software for detecting resistance-associated mutations in CMV
Cytomegalovirus (CMV) resistance testing by targeted next-generation sequencing (NGS) allows for the simultaneous analysis of multiple genes. We developed and validated an amplicon-based Ion Torrent NGS assay to detect CMV resistance mutations in UL27, UL54, UL56, and UL97 and compared the results to standard Sanger sequencing. NGS primers were designed to generate 83 overlapping amplicons of four CMV genes (~10 kb encompassing 138 mutation sites). An open-access software plugin was developed to perform read alignment, call variants, and interpret drug resistance. Plasmids were tested to determine NGS error rate and minor variant limit of detection. NGS limit of detection was determined using the CMV WHO International Standard and quantified clinical specimens. Reproducibility was also assessed. After establishing quality control metrics, 185 patient specimens previously tested using Sanger were reanalyzed by NGS. The NGS assay had a low error rate (<0.05%) and high accuracy (95%) for detecting CMV-associated resistance mutations present at ≥5% in contrived mixed populations. Mutation sites were reproducibly sequenced with 40× coverage when plasma viral loads were ≥2.6 log IU/mL. NGS detected the same resistance-associated mutations identified by Sanger in 68/69 (98.6%) specimens. In 16 specimens, NGS detected 18 resistance mutations that Sanger failed to detect; 14 were low-frequency variants (<20%), and six would have changed the drug resistance interpretation. The NGS assay showed excellent agreement with Sanger and generated high-quality sequence from low viral load specimens. Additionally, the higher resolution and analytic sensitivity of NGS potentially enables earlier detection of antiviral resistance.
- Open Access
Repeat Testing of Mpox Specimens with Late CTs Improves Detection of Potential False Positive Cases
The global outbreak of mpox necessitated the rapid development of clinical assays for monkeypox virus detection. While the majority of mpox specimens have high viral loads with corresponding early CT values, reports have indicated some specimens with late CT values can represent false positive results. To mitigate this risk, the Centers for Disease Control and Prevention (CDC) published an advisory recommending repeat testing of all specimens with CT values ≥34. However, limited experimental data was available to support this specific cutoff. In this study, we examine whether a more conservative approach in which all specimens with CT values ≥29 are repeated would improve the detection of potential false positive results. Compared to the CDC algorithm, our approach identified an additional 20% (5/25) of potential false positive results. To assess the impact of this cutoff on laboratory workload, we estimated the expected increase in test volume and turnaround time (TAT) relative to the CDC method. Using a lower repeat threshold, test volume increased by 0.7% and the mean TAT for positive specimens increased by less than 15 minutes. Overall, a lower threshold than recommended by the CDC for repeating late CT mpox specimens may reduce the number of false positives reported while minimally impacting testing volume and TAT.
Open AccessRepeat Testing of Mpox Specimens with Late CTs Improves Detection of Potential False Positive Cases
The global outbreak of mpox necessitated the rapid development of clinical assays for monkeypox virus detection. While the majority of mpox specimens have high viral loads with corresponding early CT values, reports have indicated some specimens with late CT values can represent false positive results. To mitigate this risk, the Centers for Disease Control and Prevention (CDC) published an advisory recommending repeat testing of all specimens with CT values ≥34. However, limited experimental data was available to support this specific cutoff. In this study, we examine whether a more conservative approach in which all specimens with CT values ≥29 are repeated would improve the detection of potential false positive results. Compared to the CDC algorithm, our approach identified an additional 20% (5/25) of potential false positive results. To assess the impact of this cutoff on laboratory workload, we estimated the expected increase in test volume and turnaround time (TAT) relative to the CDC method. Using a lower repeat threshold, test volume increased by 0.7% and the mean TAT for positive specimens increased by less than 15 minutes. Overall, a lower threshold than recommended by the CDC for repeating late CT mpox specimens may reduce the number of false positives reported while minimally impacting testing volume and TAT.
- 20 July 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (7) , e0025322
HIV-1 Drug Resistance Assay Using Ion Torrent Next Generation Sequencing and On-Instrument End-to-End Analysis Software
HIV-1 antiretroviral therapy management requires sequencing the protease, reverse transcriptase, and integrase portions of the HIV-1 pol gene. Most resistance testing is performed with Sanger sequencing, which has limited ability to detect minor variants.
- 20 July 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (7) , e0025322
HIV-1 Drug Resistance Assay Using Ion Torrent Next Generation Sequencing and On-Instrument End-to-End Analysis Software
HIV-1 antiretroviral therapy management requires sequencing the protease, reverse transcriptase, and integrase portions of the HIV-1 pol gene. Most resistance testing is performed with Sanger sequencing, which has limited ability to detect minor variants.
- Open Access
- 16 June 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (179) , 20210155
Efficient and effective single-step screening of individual samples for SARS-CoV-2 RNA using multi-dimensional pooling and Bayesian inference
Rapid and widespread implementation of infectious disease surveillance is a critical component in the response to novel health threats. Molecular assays are the preferred method to detect a broad range of viral pathogens with high sensitivity and specificity. The implementation of molecular assay testing in a rapidly evolving public health emergency, such as the ongoing COVID-19 pandemic, can be hindered by resource availability or technical constraints. We present a screening strategy that is easily scaled up to support a sustained large volume of testing over long periods of time. This non-adaptive pooled-sample screening protocol employs Bayesian inference to yield a reportable outcome for each individual sample in a single testing step (no confirmation of positive results required). The proposed method is validated using clinical specimens tested using a real-time reverse transcription polymerase chain reaction test for SARS-CoV-2. This screening protocol has substantial advantages for its implementation, including higher sample throughput, faster time to results, no need to retrieve previously screened samples from storage to undergo retesting, and excellent performance of the algorithm's sensitivity and specificity compared with the individual test's metrics.
- 16 June 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (179) , 20210155
Open AccessEfficient and effective single-step screening of individual samples for SARS-CoV-2 RNA using multi-dimensional pooling and Bayesian inference
Rapid and widespread implementation of infectious disease surveillance is a critical component in the response to novel health threats. Molecular assays are the preferred method to detect a broad range of viral pathogens with high sensitivity and specificity. The implementation of molecular assay testing in a rapidly evolving public health emergency, such as the ongoing COVID-19 pandemic, can be hindered by resource availability or technical constraints. We present a screening strategy that is easily scaled up to support a sustained large volume of testing over long periods of time. This non-adaptive pooled-sample screening protocol employs Bayesian inference to yield a reportable outcome for each individual sample in a single testing step (no confirmation of positive results required). The proposed method is validated using clinical specimens tested using a real-time reverse transcription polymerase chain reaction test for SARS-CoV-2. This screening protocol has substantial advantages for its implementation, including higher sample throughput, faster time to results, no need to retrieve previously screened samples from storage to undergo retesting, and excellent performance of the algorithm's sensitivity and specificity compared with the individual test's metrics.
- Open Access
In Search of Covariates of HIV-1 Subtype B Spread in the United States—A Cautionary Tale of Large-Scale Bayesian Phylogeography
Infections with HIV-1 group M subtype B viruses account for the majority of the HIV epidemic in the Western world. Phylogeographic studies have placed the introduction of subtype B in the United States in New York around 1970, where it grew into a major source of spread. Currently, it is estimated that over one million people are living with HIV in the US and that most are infected with subtype B variants. Here, we aim to identify the drivers of HIV-1 subtype B dispersal in the United States by analyzing a collection of 23,588 pol sequences, collected for drug resistance testing from 45 states during 2004–2011. To this end, we introduce a workflow to reduce this large collection of data to more computationally-manageable sample sizes and apply the BEAST framework to test which covariates associate with the spread of HIV-1 across state borders. Our results show that we are able to consistently identify certain predictors of spread under reasonable run times across datasets of up to 10,000 sequences. However, the general lack of phylogenetic structure and the high uncertainty associated with HIV trees make it difficult to interpret the epidemiological relevance of the drivers of spread we are able to identify. While the workflow we present here could be applied to other virus datasets of a similar scale, the characteristic star-like shape of HIV-1 phylogenies poses a serious obstacle to reconstructing a detailed evolutionary and spatial history for HIV-1 subtype B in the US.
Open AccessIn Search of Covariates of HIV-1 Subtype B Spread in the United States—A Cautionary Tale of Large-Scale Bayesian Phylogeography
Infections with HIV-1 group M subtype B viruses account for the majority of the HIV epidemic in the Western world. Phylogeographic studies have placed the introduction of subtype B in the United States in New York around 1970, where it grew into a major source of spread. Currently, it is estimated that over one million people are living with HIV in the US and that most are infected with subtype B variants. Here, we aim to identify the drivers of HIV-1 subtype B dispersal in the United States by analyzing a collection of 23,588 pol sequences, collected for drug resistance testing from 45 states during 2004–2011. To this end, we introduce a workflow to reduce this large collection of data to more computationally-manageable sample sizes and apply the BEAST framework to test which covariates associate with the spread of HIV-1 across state borders. Our results show that we are able to consistently identify certain predictors of spread under reasonable run times across datasets of up to 10,000 sequences. However, the general lack of phylogenetic structure and the high uncertainty associated with HIV trees make it difficult to interpret the epidemiological relevance of the drivers of spread we are able to identify. While the workflow we present here could be applied to other virus datasets of a similar scale, the characteristic star-like shape of HIV-1 phylogenies poses a serious obstacle to reconstructing a detailed evolutionary and spatial history for HIV-1 subtype B in the US.
- 1 May 2017
- Published by Elsevier in Journal of Clinical Virology
- Vol. 90, 52-56
Sequencing of the Hepatitis D Virus RNA WHO International Standard
- 1 May 2017
- Published by Elsevier in Journal of Clinical Virology
- Vol. 90, 52-56
Sequencing of the Hepatitis D Virus RNA WHO International Standard
- 1 April 2015
- Published by Elsevier in Journal of Clinical Virology
- Vol. 65, 54-57
HCV RNA measurement in samples with diverse genotypes using versions 1 and 2 of the Roche COBAS® AmpliPrep/COBAS® TaqMan® HCV test
- 1 April 2015
- Published by Elsevier in Journal of Clinical Virology
- Vol. 65, 54-57
HCV RNA measurement in samples with diverse genotypes using versions 1 and 2 of the Roche COBAS® AmpliPrep/COBAS® TaqMan® HCV test
- 1 September 2013
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 77 (1) , 25-30
Evaluation of the Roche COBAS AmpliPrep/COBAS TaqMan HCV Test
- 1 September 2013
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 77 (1) , 25-30
Evaluation of the Roche COBAS AmpliPrep/COBAS TaqMan HCV Test
- Open Access
- 1 August 2013
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 51 (8) , 2662-2669
Large-Scale Analysis of the Prevalence and Geographic Distribution of HIV-1 Non-B Variants in the United States
The genetic diversity of human immunodeficiency virus type 1 (HIV-1) has significant implications for diagnosis, vaccine development, and clinical management of patients. Although HIV-1 subtype B is predominant in the United States, factors such as global travel, immigration, and military deployment have the potential to increase the proportion of non-subtype B infections. Limited data are available on the prevalence and distribution of non-B HIV-1 strains in the United States. We sought to retrospectively examine the prevalence, geographic distribution, diversity, and temporal trends of HIV-1 non-B infections in samples obtained by ARUP Laboratories, a national reference laboratory, from all regions of the United States. HIV-1 pol sequences from 24,386 specimens collected from 46 states between 2004 and September 2011 for drug resistance genotyping were analyzed using the REGA HIV-1 Subtyping Tool, version 2.0. Sequences refractory to subtype determination or reported as non-subtype B by this tool were analyzed by PHYLIP version 3.5 and Simplot version 3.5.1. Non-subtype B strains accounted for 3.27% (798/24,386) of specimens. The 798 non-B specimens were received from 37 states and included 5 subtypes, 23 different circulating recombinant forms (CRFs), and 39 unique recombinant forms (URFs). The non-subtype B prevalence varied from 0% in 2004 (0/54) to 4.12% in 2011 (201/4,884). This large-scale analysis reveals that the diversity of HIV-1 in the United States is high, with multiple subtypes, CRFs, and URFs circulating. Moreover, the geographic distribution of non-B variants is widespread. Data from HIV-1 drug resistance testing have the potential to significantly enhance the surveillance of HIV-1 variants in the United States.
- 1 August 2013
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 51 (8) , 2662-2669
Open AccessLarge-Scale Analysis of the Prevalence and Geographic Distribution of HIV-1 Non-B Variants in the United States
The genetic diversity of human immunodeficiency virus type 1 (HIV-1) has significant implications for diagnosis, vaccine development, and clinical management of patients. Although HIV-1 subtype B is predominant in the United States, factors such as global travel, immigration, and military deployment have the potential to increase the proportion of non-subtype B infections. Limited data are available on the prevalence and distribution of non-B HIV-1 strains in the United States. We sought to retrospectively examine the prevalence, geographic distribution, diversity, and temporal trends of HIV-1 non-B infections in samples obtained by ARUP Laboratories, a national reference laboratory, from all regions of the United States. HIV-1 pol sequences from 24,386 specimens collected from 46 states between 2004 and September 2011 for drug resistance genotyping were analyzed using the REGA HIV-1 Subtyping Tool, version 2.0. Sequences refractory to subtype determination or reported as non-subtype B by this tool were analyzed by PHYLIP version 3.5 and Simplot version 3.5.1. Non-subtype B strains accounted for 3.27% (798/24,386) of specimens. The 798 non-B specimens were received from 37 states and included 5 subtypes, 23 different circulating recombinant forms (CRFs), and 39 unique recombinant forms (URFs). The non-subtype B prevalence varied from 0% in 2004 (0/54) to 4.12% in 2011 (201/4,884). This large-scale analysis reveals that the diversity of HIV-1 in the United States is high, with multiple subtypes, CRFs, and URFs circulating. Moreover, the geographic distribution of non-B variants is widespread. Data from HIV-1 drug resistance testing have the potential to significantly enhance the surveillance of HIV-1 variants in the United States.