HMHéctor González Menéndez

Héctor González Menéndez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Héctor González Menéndez has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative analysis of two navigation techniques based on augmented reality technology for the orthodontic mini-implants placement

    by Elena Riad Deglow, Álvaro Zubizarreta-Macho, Héctor González Menéndez, Juan Lorrio Castro, Agustín Galparsoro Catalán, Georgia Tzironi, Ana Belén Lobo Galindo, Luis Óscar Alonso Ezpeleta, Sofía Hernández Montero

    To analyze and compare the accuracy and root contact prevalence, comparing a conventional freehand technique and two navigation techniques based on augmented reality technology for the orthodontic self-drilling mini-implants placement. Methods Two hundred and seven orthodontic self-drilling mini-implants were placed using either a conventional freehand technique (FHT) and two navigation techniques based on augmented reality technology (AR TOOTH and AR SCREWS). Accuracy across different dental sectors was also analyzed. CBCT and intraoral scans were taken both prior to and following orthodontic self-drilling mini-implants placement. The deviation angle and horizontal were then analyzed; these measurements were taken at the coronal entry point and apical endpoint between the planned and performed orthodontic self-drilling mini-implants. In addition, any complications resulting from mini-implant placement, such as spot perforations, were also analyzed across all dental sectors.Results The statistical analysis showed significant differences between study groups with regard to the coronal entry-point (p < 0.001), apical end-point(p < 0.001) and angular deviations (p < 0.001). Furthermore, statistically significant differences were shown between the orthodontic self-drilling mini-implants placement site at the coronal entry-point (p < 0.0001) and apical end-point (p < 0.001). Additionally, eight root perforations were observed in the FHT group, while there were no root perforations in the two navigation techniques based on augmented reality technology.Conclusions The navigation techniques based on augmented reality technology has an effect on the accuracy of orthodontic self-drilling mini-implants placement and results in fewer intraoperative complications, comparing to the conventional free-hand technique. The AR TOOTH augmented reality technique showed more accurate results between planned and placed orthodontic self-drilling mini-implants, comparing to the AR SCREWS and conventional free-hand techniques. The navigation techniques based on augmented reality technology showed fewer intraoperative complications, comparing to the conventional free-hand technique.


  • Open Access

    A Replicable and Reproducible Digital Method for Quantifying Maxillary Sinus Airway Changes after Sinus Lifts Using the Lateral Window Approach Technique—A Retrospective Study

    by Héctor González Menéndez, Paulina Rodríguez Torres, Blanca Muñoz Jiménez, Agustín Galparsoro Catalán, Pilar Velasco Bohórquez, Georgia Tzironi, Lara San Hipólito Marín, Álvaro Zubizarreta Macho, Sofía Hernández Montero

    In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. Material and Methods: Thirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique. Results: The variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples. Conclusion: The novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.


  • Open Access

    Survival Rate and Prosthetic and Sinus Complications of Zygomatic Dental Implants for the Rehabilitation of the Atrophic Edentulous Maxilla: A Systematic Review and Meta-Analysis

    by David Gutiérrez Muñoz, Caterina Obrador Aldover, Álvaro Zubizarreta-Macho, Héctor González Menéndez, Juan Lorrio Castro, David Peñarrocha-Oltra, José María Montiel-Company, Sofía Hernández Montero

    The aim of this systematic review and meta-analysis was to analyze and compare the survival rate and prosthetic and sinus complications of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla. Materials and methods: We conducted a systematic literature review and meta-analysis, based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the survival rate and prosthetic and sinus complications of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla. Four databases were consulted during the literature search: Pubmed–Medline, Scopus, Embase, and Web of Science. After eliminating duplicate articles and applying the inclusion criteria, 46 articles were selected for the qualitative analysis and 32 for the quantitative analysis. Results: Four randomized controlled trials, 19 prospective clinical studies, 20 retrospective studies, and 3 case series were included in the meta-analysis. Conventional dental implants failure (n = 3549) were seen in 2.89% (IC-95% 1.83–3.96%), while zygomatic dental implants failure (n = 1895) were seen in 0.69% (IC-95% 0.21–1.16%). The measure of the effect size used was the Odds Ratio, which was estimated at 2.05 with a confidence interval of 95% between 1.22 and 3.44 (z test = 2.73; p-value = 0.006). The failure risk of conventional dental implants is 2.1 times higher than that of zygomatic dental implants. Slight heterogeneity was determined in the meta-analysis between 23 combined studies (Q test = 32.4; p-value = 0.070; I2 = 32.1%). Prosthetic complications were recorded in 4.9% (IC-95% 2.7–7.3%) and mild heterogeneity was observed in a meta-analysis of 28 combined studies (Q test = 88.2; p-value = 0.001; I2 = 69.4%). Sinus complications were seen in 4.7% (IC-95% 2.8–6.5%) and mild heterogeneity was observed in a meta-analysis of 32 combined studies (Q test = 75.3; p-value = 0.001; I2 = 58.8%). Conclusions: The high survival rate and low prosthetic and sinus complications related to zygomatic dental implants suggest the use of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla.