Zheng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zheng Zhou has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Xuhong Zhou
10 shared publicationsDan Gan
6 shared publications- Dan Gan
Chongqing University
4 shared publications Feng Yan
Structural Engineer, Dept. of Structural Design, Chongqing Jizhunfangzhong Architectural Design Co., Ltd., Chongqing 401120, China
2 shared publicationsBiao Yan
1 shared publicationCaijun Shi
1 shared publication
Latest Publications
- 26 August 2026
- Published by Elsevier in Structures
- Vol. 92
Experimental study on size effect in cyclic-loaded square CFST ultra-short columns
- 26 August 2026
- Published by Elsevier in Structures
- Vol. 92
Experimental study on size effect in cyclic-loaded square CFST ultra-short columns
- 22 August 2025
- Published by Elsevier in Structures
- Vol. 80
Experimental study on axial compression behavior of RC beam to square CFST column joints with large openings
- 22 August 2025
- Published by Elsevier in Structures
- Vol. 80
Experimental study on axial compression behavior of RC beam to square CFST column joints with large openings
- 27 February 2025
- Published by Elsevier in Structures
- Vol. 74
Machine learning-based improved plastic stress distribution method for strength prediction of CFST members
- 27 February 2025
- Published by Elsevier in Structures
- Vol. 74
Machine learning-based improved plastic stress distribution method for strength prediction of CFST members
- 11 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (1) , 465-480
Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending
Developing offshore wind power can effectively reduce carbon emissions, and adopting large‐capacity wind turbines is an important way to achieve cost reduction and efficiency increase. With increasing power capacity, the hub height and rotor‐nacelle assemblies (RNA) load will increase significantly. Ultra‐high performance concrete (UHPC) possesses ultra‐high compressive performance, good tensile, fatigue, and corrosion resistance, and thus is an effective way to further improve the mechanical performance and economic efficiency of tall offshore wind turbine (OWT) towers. Evaluation of ultimate strength is an essential aspect of design for OWT towers, and the tower structure is mainly under the combined action of axial compression from the self‐weight and RNA loads and bending from the eccentricities of RNA and aerodynamic loads from the rotor on the tower top. In this work, the mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending was numerically investigated. The finite element (FE) analyses were carried out using ABAQUS, and the material and geometric nonlinearity were considered in the model, as well as the tensile strain hardening properties of UHPC. The FE models were firstly verified by the typical experimental results of UHPC hollow columns, reinforced UHPC beams, prestressed UHPC beams, and prestressed concrete‐steel hybrid wind turbine tower model. Then the parametric study was carried out, and the parameters included the control stress and number of prestressing tendons, rib number, diameter‐to‐thickness ratio of the UHPC column, steel ratio of longitudinal reinforcement, axial load ratio, and UHPC strength. The calculation methods for flexural capacity of prestressed UHPC wind turbine tower columns were finally proposed, and were found to agree well with the modeling results.
- 11 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (1) , 465-480
Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending
Developing offshore wind power can effectively reduce carbon emissions, and adopting large‐capacity wind turbines is an important way to achieve cost reduction and efficiency increase. With increasing power capacity, the hub height and rotor‐nacelle assemblies (RNA) load will increase significantly. Ultra‐high performance concrete (UHPC) possesses ultra‐high compressive performance, good tensile, fatigue, and corrosion resistance, and thus is an effective way to further improve the mechanical performance and economic efficiency of tall offshore wind turbine (OWT) towers. Evaluation of ultimate strength is an essential aspect of design for OWT towers, and the tower structure is mainly under the combined action of axial compression from the self‐weight and RNA loads and bending from the eccentricities of RNA and aerodynamic loads from the rotor on the tower top. In this work, the mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending was numerically investigated. The finite element (FE) analyses were carried out using ABAQUS, and the material and geometric nonlinearity were considered in the model, as well as the tensile strain hardening properties of UHPC. The FE models were firstly verified by the typical experimental results of UHPC hollow columns, reinforced UHPC beams, prestressed UHPC beams, and prestressed concrete‐steel hybrid wind turbine tower model. Then the parametric study was carried out, and the parameters included the control stress and number of prestressing tendons, rib number, diameter‐to‐thickness ratio of the UHPC column, steel ratio of longitudinal reinforcement, axial load ratio, and UHPC strength. The calculation methods for flexural capacity of prestressed UHPC wind turbine tower columns were finally proposed, and were found to agree well with the modeling results.
- 16 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 86
Seismic evaluation of stiffened CFST column to RC beam frames
- 16 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 86
Seismic evaluation of stiffened CFST column to RC beam frames
- 21 April 2023
- Published by Elsevier in Thin-Walled Structures
- Vol. 187
Modeling of cyclically loaded square thin-walled CSFT columns stiffened by diagonal ribs using OpenSees
- 21 April 2023
- Published by Elsevier in Thin-Walled Structures
- Vol. 187
Modeling of cyclically loaded square thin-walled CSFT columns stiffened by diagonal ribs using OpenSees
- 13 November 2022
- Published by Wiley in Structural Concrete
- Vol. 24 (3) , 3674-3691
Axial compression behavior of reinforced concrete beam to square thin‐walled concrete‐filled steel tube column joints stiffened by internal diaphragms
A joint system was proposed to connect square thin‐walled concrete‐filled steel tube (CFST) columns and reinforced concrete (RC) beams. In the system, longitudinal beam reinforcing bars are continuous through the joint zone by passing the rectangular holes in the steel tube, aiming to achieve direct load‐transfer of the beam and joint integrity; and the square thin‐walled steel tube with holes is strengthened by internal diaphragms. Previous cyclic tests showed that the proposed joint system satisfied the requirements of strong‐joint weak‐component, namely the shear capacity of the joint zone was larger than that provided by CFST columns and RC beams. However, further research was necessary to evaluate the behavior under axial compression, as the discontinuous diagonal ribs and holes in the joint steel tube weakened the load capacity. In this investigation, the effect of internal diaphragms was first evaluated based on the axial compression tests on six square CFST stub columns. The test results showed that the internal diaphragms effectively improved the strength and ductility. The finite element analyses (FEA) on square CFST columns and RC beam to CFST column joints stiffened by internal diaphragms were then carried out based on the verified FEA models. The analysis results showed that thicker internal diaphragms increased the strength, and changed the failure mode from the column‐center failure to column‐end failure for columns and from the joint failure to column failure for joints, respectively. Finally, the mechanics‐based models and axial strength equations of square CFST columns and RC beam to CFST column joints stiffened by internal diaphragms were proposed, and the predictions agreed well with the test and analysis results.
- 13 November 2022
- Published by Wiley in Structural Concrete
- Vol. 24 (3) , 3674-3691
Axial compression behavior of reinforced concrete beam to square thin‐walled concrete‐filled steel tube column joints stiffened by internal diaphragms
A joint system was proposed to connect square thin‐walled concrete‐filled steel tube (CFST) columns and reinforced concrete (RC) beams. In the system, longitudinal beam reinforcing bars are continuous through the joint zone by passing the rectangular holes in the steel tube, aiming to achieve direct load‐transfer of the beam and joint integrity; and the square thin‐walled steel tube with holes is strengthened by internal diaphragms. Previous cyclic tests showed that the proposed joint system satisfied the requirements of strong‐joint weak‐component, namely the shear capacity of the joint zone was larger than that provided by CFST columns and RC beams. However, further research was necessary to evaluate the behavior under axial compression, as the discontinuous diagonal ribs and holes in the joint steel tube weakened the load capacity. In this investigation, the effect of internal diaphragms was first evaluated based on the axial compression tests on six square CFST stub columns. The test results showed that the internal diaphragms effectively improved the strength and ductility. The finite element analyses (FEA) on square CFST columns and RC beam to CFST column joints stiffened by internal diaphragms were then carried out based on the verified FEA models. The analysis results showed that thicker internal diaphragms increased the strength, and changed the failure mode from the column‐center failure to column‐end failure for columns and from the joint failure to column failure for joints, respectively. Finally, the mechanics‐based models and axial strength equations of square CFST columns and RC beam to CFST column joints stiffened by internal diaphragms were proposed, and the predictions agreed well with the test and analysis results.
- 16 July 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 58
Shear strength of stiffened square thin-walled concrete-filled steel tubular columns
- 16 July 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 58
Shear strength of stiffened square thin-walled concrete-filled steel tubular columns
- 1 March 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (3) , 04021299
Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading
This study proposes a through-beam composite joint system to connect square concrete-filled steel tubular (CFST) columns and concrete-filled U-shaped steel (CFUS) beams. In the joint system, channel-shaped holes in the square steel tube allow direct load transfer of the beam. Two procedures for constructing the joints, denoting two types of joint details (i.e., Type-I and Type-II), are proposed to facilitate field installation. Six cruciform joints were tested under combined constant axial compression and cyclic lateral loading. Three Type-I joints were tested. The main test parameters were the loading procedure and the axial load ratio applied on the CFST column. All Type-I specimens reached their beam flexural capacities followed by the fracture of fillet welds at beam ends, as well as the fracture of the reduced steel section within the joint zone. Three Type-II joints were constructed with the same column and beam section dimensions as the Type-I specimens. The main test parameters were the additional flexural rebars at beam ends and the axial load ratio. All Type-II specimens reached their beam flexural capacities, followed by the fracture of the heat-affected zone at beam ends. All specimens failed in a ductile manner, had favorable hysteretic performance, and complied with the acceptance criteria. Design considerations are proposed based on the test and analysis results.
- 1 March 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (3) , 04021299
Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading
This study proposes a through-beam composite joint system to connect square concrete-filled steel tubular (CFST) columns and concrete-filled U-shaped steel (CFUS) beams. In the joint system, channel-shaped holes in the square steel tube allow direct load transfer of the beam. Two procedures for constructing the joints, denoting two types of joint details (i.e., Type-I and Type-II), are proposed to facilitate field installation. Six cruciform joints were tested under combined constant axial compression and cyclic lateral loading. Three Type-I joints were tested. The main test parameters were the loading procedure and the axial load ratio applied on the CFST column. All Type-I specimens reached their beam flexural capacities followed by the fracture of fillet welds at beam ends, as well as the fracture of the reduced steel section within the joint zone. Three Type-II joints were constructed with the same column and beam section dimensions as the Type-I specimens. The main test parameters were the additional flexural rebars at beam ends and the axial load ratio. All Type-II specimens reached their beam flexural capacities, followed by the fracture of the heat-affected zone at beam ends. All specimens failed in a ductile manner, had favorable hysteretic performance, and complied with the acceptance criteria. Design considerations are proposed based on the test and analysis results.
- 1 October 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 145 (10)
Improved Composite Effect of Square Concrete-Filled Steel Tubes with Diagonal Binding Ribs
- 1 October 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 145 (10)
Improved Composite Effect of Square Concrete-Filled Steel Tubes with Diagonal Binding Ribs