Adam Frischknecht
Research Subjects
Research Interests
Adam Frischknecht has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fahad Kamran
Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor
1 shared publication - Jenna Wiens
University of Michigan, Ann Arbor, USA
1 shared publication - Kathleen H. Sienko
University of Michigan
1 shared publication - Victor C. Le
Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, USA
1 shared publication
Latest Publications
- Open Access
Noninvasive Estimation of Hydration Status in Athletes Using Wearable Sensors and a Data-Driven Approach Based on Orthostatic Changes
Dehydration beyond 2% bodyweight loss should be monitored to reduce the risk of heat-related injuries during exercise. However, assessments of hydration in athletic settings can be limited in their accuracy and accessibility. In this study, we sought to develop a data-driven noninvasive approach to measure hydration status, leveraging wearable sensors and normal orthostatic movements. Twenty participants (10 males, 25.0 ± 6.6 years; 10 females, 27.8 ± 4.3 years) completed two exercise sessions in a heated environment: one session was completed without fluid replacement. Before and after exercise, participants performed 12 postural movements that varied in length (up to 2 min). Logistic regression models were trained to estimate dehydration status given their heart rate responses to these postural movements. The area under the receiver operating characteristic curve (AUROC) was used to parameterize the model’s discriminative ability. Models achieved an AUROC of 0.79 (IQR: 0.75, 0.91) when discriminating 2% bodyweight loss. The AUROC for the longer supine-to-stand postural movements and shorter toe-touches were similar (0.89, IQR: 0.89, 1.00). Shorter orthostatic tests achieved similar accuracy to clinical tests. The findings suggest that data from wearable sensors can be used to accurately estimate mild dehydration in athletes. In practice, this method may provide an additional measurement for early intervention of severe dehydration.
Open AccessNoninvasive Estimation of Hydration Status in Athletes Using Wearable Sensors and a Data-Driven Approach Based on Orthostatic Changes
Dehydration beyond 2% bodyweight loss should be monitored to reduce the risk of heat-related injuries during exercise. However, assessments of hydration in athletic settings can be limited in their accuracy and accessibility. In this study, we sought to develop a data-driven noninvasive approach to measure hydration status, leveraging wearable sensors and normal orthostatic movements. Twenty participants (10 males, 25.0 ± 6.6 years; 10 females, 27.8 ± 4.3 years) completed two exercise sessions in a heated environment: one session was completed without fluid replacement. Before and after exercise, participants performed 12 postural movements that varied in length (up to 2 min). Logistic regression models were trained to estimate dehydration status given their heart rate responses to these postural movements. The area under the receiver operating characteristic curve (AUROC) was used to parameterize the model’s discriminative ability. Models achieved an AUROC of 0.79 (IQR: 0.75, 0.91) when discriminating 2% bodyweight loss. The AUROC for the longer supine-to-stand postural movements and shorter toe-touches were similar (0.89, IQR: 0.89, 1.00). Shorter orthostatic tests achieved similar accuracy to clinical tests. The findings suggest that data from wearable sensors can be used to accurately estimate mild dehydration in athletes. In practice, this method may provide an additional measurement for early intervention of severe dehydration.