Zhengshu Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhengshu Dai has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Hua Zhang
3 shared publications- Anthony M. Jacobi
Air Conditioning and Refrigeration Center (ACRC), Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
2 shared publications K. Nawaz
Department of Mechanical Science and Engineering , University of Illinois , Urbana, Illinois, USA
2 shared publicationsKashif Nawaz
2 shared publicationsXuejun Zhang
2 shared publicationsBo Li
1 shared publication
Latest Publications
- 29 December 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 183, 108-122
Study on irreversibility in an ejector with zeotropic mixtures using direct entropy analysis method
- 29 December 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 183, 108-122
Study on irreversibility in an ejector with zeotropic mixtures using direct entropy analysis method
- 30 January 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 172, 266-283
Advanced exergy analysis on an ejector using zeotropic mixture in a refrigeration system
- 30 January 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 172, 266-283
Advanced exergy analysis on an ejector using zeotropic mixture in a refrigeration system
- 30 October 2024
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 208
Advances in ejector research for multi-effect thermal vapor compression desalination
- 30 October 2024
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 208
Advances in ejector research for multi-effect thermal vapor compression desalination
- 1 January 2012
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 33 (1) , 21-30
A Comparison of Metal-Foam Heat Exchangers to Compact Multilouver Designs for Air-Side Heat Transfer Applications
High-porosity metal foams, with novel thermal, mechanical, electrical, and acoustic properties, are being more widely used in various industrial applications. In this paper, open-cell aluminum foam is considered as a highly compact replacement for conventional louver fins in brazed aluminum heat exchangers. A model based on the ϵ-NTU method is developed to compare the flat-tube, serpentine louver-fin heat exchanger to the flat-tube metal-foam heat exchanger. The two heat exchangers are subjected to identical thermal-hydraulic requirements, and volume, mass, and cost of the metal-foam and louver-fin designs are compared. The results show that the same performance is achieved using the metal-foam heat exchanger but a lighter and smaller heat exchanger is required. However, the cost of the metal-foam heat exchanger is currently much higher than that of the louver-fin heat exchanger, because of the high price of metal foams. If the price of metal foam falls to equal that of louver-fin stock (per unit mass), then the metal-foam heat exchanger will be less expensive, smaller, and lighter than the louver-fin heat exchanger, with identical thermal performance.
- 1 January 2012
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 33 (1) , 21-30
A Comparison of Metal-Foam Heat Exchangers to Compact Multilouver Designs for Air-Side Heat Transfer Applications
High-porosity metal foams, with novel thermal, mechanical, electrical, and acoustic properties, are being more widely used in various industrial applications. In this paper, open-cell aluminum foam is considered as a highly compact replacement for conventional louver fins in brazed aluminum heat exchangers. A model based on the ϵ-NTU method is developed to compare the flat-tube, serpentine louver-fin heat exchanger to the flat-tube metal-foam heat exchanger. The two heat exchangers are subjected to identical thermal-hydraulic requirements, and volume, mass, and cost of the metal-foam and louver-fin designs are compared. The results show that the same performance is achieved using the metal-foam heat exchanger but a lighter and smaller heat exchanger is required. However, the cost of the metal-foam heat exchanger is currently much higher than that of the louver-fin heat exchanger, because of the high price of metal foams. If the price of metal foam falls to equal that of louver-fin stock (per unit mass), then the metal-foam heat exchanger will be less expensive, smaller, and lighter than the louver-fin heat exchanger, with identical thermal performance.
- 1 July 2010
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 37 (6) , 575-580
Correcting and extending the Boomsma–Poulikakos effective thermal conductivity model for three-dimensional, fluid-saturated metal foams
- 1 July 2010
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 37 (6) , 575-580
Correcting and extending the Boomsma–Poulikakos effective thermal conductivity model for three-dimensional, fluid-saturated metal foams