ACAndrea Corna

Andrea Corna

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrea Corna has a total of 86 co-authors. Here are the top co-authors by number of shared publications:

  • Günther Zeck

    Institute of Biomedical Electronics, TU Wien, Gußhausstraße 27-29, 1040 Vienna, Austria

    7 shared publications
  • Ahmad Salti

    Research Group Cellular and Molecular Ophthalmology, University Clinic for Ophthalmology and Optometry, Johannes Kepler University Linz, Kepler University Hospital, Altenberger Strasse 69, 4040 Linz and Krankenhausstrasse 5, 4020 Linz, Austria

    2 shared publications
  • Alessandro Bellapianta

    Research Group Cellular and Molecular Ophthalmology, University Clinic for Ophthalmology and Optometry, Johannes Kepler University Linz, Kepler University Hospital, Altenberger Strasse 69, 4040 Linz and Krankenhausstrasse 5, 4020 Linz, Austria

    2 shared publications
  • Ali Khiat

    Centre for Electronics Frontiers, University of Southampton, Southampton, SO17 1BJ, UK

    2 shared publications
  • Giacomo Indiveri

    University of Zürich and ETH Zürich

    2 shared publications
  • Guenther Zeck

    Biomedical Electronics and Systems, Vienna University of Technology Faculty of Electrical Engineering and Information Technology, Gußhausstr. 27, Wien, Wien, 1040, AUSTRIA

    2 shared publications

Latest Publications

  • Open Access

    Resting-state electroretinography reveals pathological retinal oscillations in retinitis pigmentosa mice and patients

    by David G. Litvin, Alexia Boizot, Andrea Corna, Aurélie Navarro, Josiane Keller, Marc O. Heuschkel, Adrien Roux, Günther Zeck, Hoai Viet Tran, Diego Ghezzi

    Retinal remodeling occurs in both retinitis pigmentosa and age-related macular degeneration. However, it is still unknown whether spared retinal circuits are also functionally altered. Functional changes have been observed in animal models of retinitis pigmentosa, including the emergence of bursting oscillatory activity in retinal ganglion cells. Yet, comparable oscillatory activity, or other functional alterations, has not been demonstrated in patients. To address this gap, here we report a non-invasive corneal neurotechnology measuring in-vivo resting-state electroretinography and analyzing its frequency content and temporal characteristics to identify biomarkers of functional remodeling. We document that retinal remodeling induces bursting oscillatory activity in-vivo in retinitis pigmentosa mouse models and translate these results to patients. Moreover, we showed in mice that bursting oscillatory activity can be pharmacologically modulated in-vivo. Furthermore, reducing this oscillatory activity increases retinal excitability to electrical stimulation. These results are crucial for a better understanding of retinal degeneration and contribute to sight restoration efforts.

  • Open Access

    Photovoltaic nanoassembly of nanowire arrays sensitized with colloidal nanocrystals for near-infrared retina photostimulation

    by Tarik S. Kaya, Humeyra N. Kaleli, Antoine Chaffiol, Andrea Corna, Corentin Joffrois, Ridvan Balamur, Ugur B. Caliskan, Asim Onal, Cigdem Pehlivan, Eren Tekinay, et al.

    Nanowires have served as a transformative platform for advanced neural and tissue interfaces. While their photovoltaic properties hold exceptional promise for neural modulation, existing photostimulation approaches predominantly rely on visible light–activated photoelectrochemical mechanisms. Here, we present a solution-processed photovoltaic nanoassembly comprising a ZnO nanowire array sensitized with AgBiS 2 nanocrystals that enables efficient near-infrared (NIR) neural stimulation through capacitive photocurrents. By optimizing nanowire morphology and nanocrystal interdigitation, the platform achieves high charge injection densities (tens of microcoulombs per square centimeter) at low NIR intensities (<1 milliwatt per square millimeter). The nanoassembly was subretinally placed in an ex vivo blind rat retina, where it elicited repeatable and robust responses in retinal ganglion cells under NIR pulses. Notably, these responses were achieved at light intensities substantially below established ocular safety limits. The nexus of neuronal systems and nanoassemblies offers potential for enabling unconventional visual prosthetics and advanced neuromodulation therapies.


  • Open Access

    Two-dimensional adhesion noise spectroscopy: a CMOS-based, non-invasive modality for real-time cell and tissue monitoring

    by Maximilian Ell, Nadir Talha, Woo-Bin Jung, Andrea Corna, Dennis Gong, William L. Hwang, Roland Thewes, Donhee Ham, Günther Zeck

    Non-invasive monitoring of adherent cells by adhesion noise spectroscopy without the need of optical imaging or external stimuli for lab-on-chip applications.

  • Open Access

    Near‐Infrared Organic Photovoltaic Electrodes for Subretinal Neurostimulation

    by Andrea Corna, Katarina Gugujonovic, Manuela Schiek, Alessandro Bellapianta, Paul Werginz, Amelie Ziller, Markus Clark Scharber, Ahmad Salti, Matthias Bolz, Mihai Irimia‐Vladu, et al.

    Organic semiconductors are emerging as a promising class of photovoltaic materials for neural interfaces, offering high power conversion, mechanical flexibility, biocompatibility, and tunable optoelectronic properties. In this study, the application of a D18:Y6‐based organic photovoltaic (OPV) electrode is investigated for subretinal stimulation in a model of retinal degeneration. It is demonstrated that OPV devices can be engineered to electrically stimulate the retina via network‐mediated pathways, in a manner comparable to established neurostimulation approaches. The presented OPV electrodes reliably activate retinal ganglion cells, eliciting consistent spike responses to light pulses within the near‐infrared range. The stimulation onset, spike latency, and response profiles suggest effective faradaic charge injection as a key mechanism for neuronal activation, particularly for longer pulse durations. Moreover, it is shown that both light intensity and pulse duration can be used to finely tune the neural response, offering a high degree of control over retinal ganglion cell activation. Finally, it is proven that D18:Y6 blend is biocompatible in vitro when in direct contact with human induced pluripotent stem cell (iPSC)‐derived retinal organoids and mouse explants. These results validate the photo‐electrical performance and biocompatibility of D18:Y6 OPVs and position them as a viable candidate for next‐generation, minimally invasive retinal prosthetics.


  • Open Access

    Avoidance of axonal stimulation with sinusoidal epiretinal stimulation

    by Andrea Corna, Andreea-Elena Cojocaru, Mai Thu Bui, Paul Werginz, Günther Zeck

    Objective. Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies. Approach. RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested in ex-vivo photoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution. Main results. We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23 µA (corresponding to 17.3 µC cm−2) at 40 Hz and up to a stimulation amplitude of 0.28 µA (14.8 µC cm−2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles. Significance. Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.


  • Open Access

    A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine

    by Helen Steins, Michael Mierzejewski, Lisa Brauns, Angelika Stumpf, Alina Kohler, Gerhard Heusel, Andrea Corna, Thoralf Herrmann, Peter D. Jones, Günther Zeck, et al.

    Recording neural signals from delicate autonomic nerves is a challenging task that requires the development of a low-invasive neural interface with highly selective, micrometer-sized electrodes. This paper reports on the development of a three-dimensional (3D) protruding thin-film microelectrode array (MEA), which is intended to be used for recording low-amplitude neural signals from pelvic nervous structures by penetrating the nerves transversely to reduce the distance to the axons. Cylindrical gold pillars (Ø 20 or 50 µm, ~60 µm height) were fabricated on a micromachined polyimide substrate in an electroplating process. Their sidewalls were insulated with parylene C, and their tips were optionally modified by wet etching and/or the application of a titanium nitride (TiN) coating. The microelectrodes modified by these combined techniques exhibited low impedances (~7 kΩ at 1 kHz for Ø 50 µm microelectrode with the exposed surface area of ~5000 µm²) and low intrinsic noise levels. Their functionalities were evaluated in an ex vivo pilot study with mouse retinae, in which spontaneous neuronal spikes were recorded with amplitudes of up to 66 µV. This novel process strategy for fabricating flexible, 3D neural interfaces with low-impedance microelectrodes has the potential to selectively record neural signals from not only delicate structures such as retinal cells but also autonomic nerves with improved signal quality to study neural circuits and develop stimulation strategies in bioelectronic medicine, e.g., for the control of vital digestive functions.


  • Open Access

    Electrical imaging of axonal stimulation in the retina

    by Andrea Corna, Timo Lausen, Roland Thewes, Günther Zeck

    Stimulation of axons or its avoidance plays a central role for neuroprosthetics and neural-interfaces research. One peculiar example constitutes retinal implants. Retinal implants aim to artificially activate retinal ganglion cells (RGCs) via electrical stimulation. Such stimulation, however, often generates undesired stimulation of RGC axon bundles, which leads to distorted visual percepts. In order to establish stimulation strategies avoiding axonal stimulation it is necessary to image the evoked activity in single axons. In this work we electrically imaged axonal stimulation in ex vivo mouse retina using a high-density CMOS-based microelectrode array. We demonstrate signal propagation tracking via stimulus triggered average during high frequency (100 Hz) sinusoidal electrical stimulation.


  • Open Access

    In Vitro Cytotoxicity of D18 and Y6 as Potential Organic Photovoltaic Materials for Retinal Prostheses

    by Ana Cetkovic, Alessandro Bellapianta, Mihai Irimia-Vladu, Jakob Hofinger, Cigdem Yumusak, Andrea Corna, Markus Clark Scharber, Günther Zeck, Niyazi Serdar Sariciftci, Matthias Bolz, et al.

    Millions of people worldwide are diagnosed with retinal dystrophies such as retinitis pigmentosa and age-related macular degeneration. A retinal prosthesis using organic photovoltaic (OPV) semiconductors is a promising therapeutic device to restore vision to patients at the late onset of the disease. However, an appropriate cytotoxicity approach has to be employed on the OPV materials before using them as retinal implants. In this study, we followed ISO standards to assess the cytotoxicity of D18, Y6, PFN-Br and PDIN individually, and as mixtures of D18/Y6, D18/Y6/PFN-Br and D18/Y6/PDIN. These materials were proven for their high performance as organic solar cells. Human RPE cells were put in direct and indirect contact with these materials to analyze their cytotoxicity by the MTT assay, apoptosis by flow cytometry, and measurements of cell morphology and proliferation by immunofluorescence. We also assessed electrophysiological recordings on mouse retinal explants via microelectrode arrays (MEAs) coated with D18/Y6. In contrast to PFN-Br and PDIN, all in vitro experiments show no cytotoxicity of D18 and Y6 alone or as a D18/Y6 mixture. We conclude that D18/Y6 is safe to be subsequently investigated as a retinal prosthesis.


  • Open Access

    Discrimination of simple objects decoded from the output of retinal ganglion cells upon sinusoidal electrical stimulation

    by Andrea Corna, Poornima Ramesh, Florian Jetter, Meng-Jung Lee, Jakob H. Macke, Guenther Zeck

    Objective. Most neuroprosthetic implants employ pulsatile square-wave electrical stimuli, which are significantly different from physiological inter-neuronal communication. In case of retinal neuroprosthetics, which use a certain type of pulsatile stimuli, reliable object and contrast discrimination by implanted blind patients remained challenging. Here we investigated to what extent simple objects can be discriminated from the output of retinal ganglion cells (RGCs) upon sinusoidal stimulation. Approach. Spatially confined objects were formed by different combinations of 1024 stimulating microelectrodes. The RGC activity in the ex vivo retina of photoreceptor-degenerated mouse, of healthy mouse or of primate was recorded simultaneously using an interleaved recording microelectrode array implemented in a CMOS-based chip. Main results. We report that application of sinusoidal electrical stimuli (40 Hz) in epiretinal configuration instantaneously and reliably modulates the RGC activity in spatially confined areas at low stimulation threshold charge densities (40 nC mm−2). Classification of overlapping but spatially displaced objects (1° separation) was achieved by distinct spiking activity of selected RGCs. A classifier (regularized logistic regression) discriminated spatially displaced objects (size: 5.5° or 3.5°) with high accuracy (90% or 62%). Stimulation with low artificial contrast (10%) encoded by different stimulus amplitudes generated RGC activity, which was classified with an accuracy of 80% for large objects (5.5°). Significance. We conclude that time-continuous smooth-wave stimulation provides robust, localized neuronal activation in photoreceptor-degenerated retina, which may enable future artificial vision at high temporal, spatial and contrast resolution.


  • Open Access

    Author Correction: Memristive synapses connect brain and silicon spiking neurons

    by Alexantrou Serb, Andrea Corna, Richard George, Ali Khiat, Federico Rocchi, Marco Reato, Marta Maschietto, Christian Mayr, Giacomo Indiveri, Stefano Vassanelli, et al.

    An amendment to this paper has been published and can be accessed via a link at the top of the paper.