DFDidier Ferrand

Didier Ferrand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Didier Ferrand has a total of 462 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Phase transfer between three visible lasers for coherent population trapping

    by Mathieu Collombon, Gaëtan Hagel, Cyril Chatou, Didier Guyomarc’h, Didier Ferrand, Marie Houssin, Caroline Champenois, Martina Knoop

    Stringent conditions on the phase relation of multiple photons are a prerequisite for novel protocols of high-resolution coherent spectroscopy. In a recent experiment, we have implemented an interrogation process of a Ca+-ion cloud based on three-photon coherent population trapping, with the potential to serve as a frequency reference in the THz range. This high-resolution interrogation has been made possible by phase-locking both laser sources for cooling and repumping of the trapped ions to a clock laser at 729 nm by means of an optical frequency comb. The clock laser, a titanium-sapphire laser built in our lab locked onto two high-finesse cavities reaches a linewidth of a few Hertz and a frequency stability below 10−14 at 1 s, performances which can be copied onto the two other sources. In this paper, we discuss the performances of the phase transfer between the three involved lasers via the optical frequency comb.


  • A tomography diagnostic in the visible spectrum to investigate turbulence and coherent modes in the linear plasma column Mistral

    by P. David, A. Escarguel, Y. Camenen, R. Baude, D. Ferrand

    In this paper, we describe a newly installed tomography diagnostic on the linear magnetized plasma device Mistral. The diagnostic is composed of 128 lines of sight covering a 20 cm diameter section and an acquisition rate up to 1 MHz. The measurements are done in the visible spectrum using silicon photomultiplier arrays that require a lower amplification voltage than photomultiplier tubes for similar gains and have a fast response. Tomographic reconstruction of a rotating plasma mode is shown to illustrate the capabilities of the diagnostic.


  • Open Access

    Noise Characterization of an Optical Frequency Comb Using Offline Cross-Correlation

    by Ramin Khayatzadeh, Mathieu Collombon, Didier Guyomarc'H, Didier Ferrand, Gaetan Hagel, Marie Houssin, Olivier Morizot, Caroline Champenois, Martina Knoop

    Using an offline cross-correlation technique, we have analyzed the noise behavior of a new type of optical frequency comb (OFC), which is carrier envelope offset free by configuration, due to difference frequency generation. In order to evaluate the instrument’s ultimate noise floor, the phase and amplitude noise of a stabilized OFC are measured simultaneously by using two analog-to-digital converters. Carrier recovery and phase detection are done by post-processing, eliminating the need for external phase-locked loops and complex calibration techniques. In order to adapt the measurement noise floor and the number of averages used in cross correlation, an adaptive frequency resolution for noise measurement is applied. Phase noise results are in excellent agreement with the measurements of the fluctuations of the repetition frequency of the OFC obtained from optical signal.


  • Top Cited Papers
    Open Access

    Prime Focus Spectrograph (PFS) for the Subaru telescope: overview, recent progress, and future perspectives

    by Naoyuki Tamura, Naruhisa Takato, Atsushi Shimono, Yuki Moritani, Kiyoto Yabe, Yuki Ishizuka, Akitoshi Ueda, Yukiko Kamata, Hrand Aghazarian, Stéphane Arnouts, et al.

    PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6 - 2.7Å. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.


  • THERMAP: a mid-infrared spectro-imager for space missions to small bodies in the inner solar system

    by O. Groussin, J. Licandro, J. Helbert, J. L. Reynaud, P. Levacher, M. Reyes García-Talavera, V. Alí-Lagoa, P. E. Blanc, E. Brageot, B. Davidsson, et al.


  • Open Access

    Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph

    by Hajime Sugai, Naoyuki Tamura, Hiroshi Karoji, Atsushi Shimono, Naruhisa Takato, Masahiko Kimura, Youichi Ohyama, Akitoshi Ueda, Hrand Aghazarian, Marcio Vital de Arruda, et al.

    The Prime Focus Spectrograph (PFS)1 is an optical/near-infrared multifiber spectrograph with 2394 science fibers (Fig. 1), and is scheduled to be mounted on the Subaru 8.2-m telescope. The position of each fiber is controlled by a fiber positioner, called “Cobra,” consisting of two-staged piezo-electric rotary squiggle motors. Each fiber positioner unit samples a circular patrol region of 9.5-mm diameter at the telescope focal plane, and these positioners are arrayed into a hexagonal pattern with 8-mm central distances between adjacent positioners. The whole array extends to a single hexagonal field of view (FOV) whose effective diameter is 1.3 deg. The hexagonal FOV has an advantage for efficient tiling of survey areas, compared with e.g., a circular FOV. The fibers are divided into four groups, each of which enters one of the four spectrograph modules in a slit comprising 600 or 597 science fibers in a single row. Each spectrograph module has three color arms to cover a wide wavelength region from 0.38  μm to 1.26  μm, with a mean resolving power λ/δλ of 3000. This resolution is optimal for spectroscopic surveys of fainter galaxies and stars, targeting cosmology, Galactic archaeology and galaxy/AGN evolution. To simplify the design of the spectrograph, the F/2.2 beam from the telescope wide field corrector (WFC) is increased to F/2.8 by a microlens bonded to each fiber. A double Schmidt design is used for the spectrograph modules, which are F/2.5 at the fiber side and F/1.09 at the detector side. These apertures are slightly larger than the nominal F/#, allowing for some focal ratio degradation (FRD) in the fiber. A medium spectral resolution mode with resolving power of 5000 for the red arms (0.71  μm to 0.89  μm) is also included. This addition particularly benefits important Galactic archaeology studies. This new mode is realized by using a simple grating/grism exchange mechanism without changing any other design elements. The basic characteristics of PFS are summarized in Table 1. The total efficiency from the atmosphere to the detector is expected to be around ∼10%–20%,1 depending on the wavelength and observing conditions such as telescope elevation and fiber position in FOV.


  • Current status of the spectrograph system for the SuMIRe/PFS

    by S. Vives, D. Le Mignant, J. E. Gunn, S. Smee, L. Souza de Oliveira, N. Tamura, H. Sugai, R. Barkhouser, A. Bozier, M. A. Carr, et al.


  • Integration and test activities for the SUMIRE prime focus spectrograph at LAM

    by F. Madec, Marc Jaquet, Sandrine Pascal, A. Bozier, David Le Mignant, S. Vives, D. Ferrand, T. Pegot-Ogier, G. Arthaud, M. Golebiowski, et al.


  • Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

    by Hajime Sugai, Naoyuki Tamura, Hiroshi Karoji, Atsushi Shimono, Naruhisa Takato, Masahiko Kimura, Youichi Ohyama, Akitoshi Ueda, Hrand Aghazarian, Marcio Vital de Arruda, et al.

    The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 μm to 1.26 μm, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 μm to 0.89 μm also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts (SuMIRe) project, while Hyper Suprime-Cam (HSC) works on the imaging part. HSC’s excellent image qualities have proven the high quality of the Wide Field Corrector (WFC), which PFS shares with HSC. The PFS collaboration has succeeded in the project Preliminary Design Review and is now in a phase of subsystem Critical Design Reviews and construction. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated microlens is glued to each fiber tip. The microlenses are molded glass, providing uniform lens dimensions and a variety of refractive-index selection. After successful production of mechanical and optical samples, mass production is now complete. Following careful investigations including Focal Ratio Degradation (FRD) measurements, a higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. After evaluating the statistics of positioning accuracies, collision avoidance software, and interferences (if any) within/between electronics boards, mass production will commence. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. All optical glass blanks are now being polished. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms. The active damping system against cooler vibration has been proven to work as predicted, and spectrographs have been designed to avoid small possible residual resonances.


  • Response of an artificially blown clarinet to different blowing pressure profiles

    by Baptiste Bergeot, André Almeida, Bruno Gazengel, Christophe Vergez, Didier Ferrand

    Using an artificial mouth with an accurate pressure control, the onset of the pressure oscillations inside the mouthpiece of a simplified clarinet is studied experimentally. Two time profiles are used for the blowing pressure: in a first set of experiments the pressure is increased at constant rates, then decreased at the same rate. In a second set of experiments the pressure rises at a constant rate and is then kept constant for an arbitrary period of time. In both cases the experiments are repeated for different increase rates. Numerical simulations using a simplified clarinet model blown with a constantly increasing mouth pressure are compared to the oscillating pressure obtained inside the mouthpiece. Both show that the beginning of the oscillations appears at a higher pressure values than the theoretical static threshold pressure, a manifestation of bifurcation delay. Experiments performed using an interrupted increase in mouth pressure show that the beginning of the oscillation occurs close to the stop in the increase of the pressure. Experimental results also highlight that the speed of the onset transient of the sound is roughly the same, independently of the duration of the increase phase of the blowing pressure.