Timothy Foo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Timothy Foo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Evelyn J. Hall
Unit of Environmental Sciences, Faculty of Science, University of Sydney, Sydney, NSW 2006, Australia
2 shared publications- Fernando Martinez-Taboada
Sydney School of Veterinary Science, University of Sydney, Sydney, NSW 2050, Australia
2 shared publications - Laurencie Brunel
Faculty of Sciences, School of Veterinary Sciences, The University of Sydney, Sydney, Australia
2 shared publications - Bianca Haase
Sydney School of Veterinary Science, Faculty of Science, University of Sydney, NSW, Australia
1 shared publication Cheryl Sangster
Veterinary Pathology Diagnostic Services, Sydney School of Veterinary Science, Faculty of Science, University of Sydney, NSW, Australia
1 shared publicationJames Crowley
University Veterinary Teaching Hospital Sydney, Sydney School of Veterinary Science, Faculty of Science, University of Sydney, NSW, Australia
1 shared publication
Latest Publications
- 6 September 2021
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 34 (06) , 401-410
Feline Skeletal Reference Guide: A Cadaveric Radiographic Measurement on Lower Limb Extremities
Objective The aim of this study was to create a feline reference database for the length, width and slenderness (length to width ratio) of metacarpal and metatarsal bones, radius and tibia.Study Design Radiographs of the radius, tibia, metacarpus and metatarsus were performed in domestic short hair cat cadavers (n = 40). Length and width of the aforementioned bones were measured in mature domestic shorthair cats and bone slenderness (length/width) and index ratios calculated.Results A significant skeletal sex dimorphism exists in cats, with bones of the metacarpus, metatarsus, radius and tibia generally longer and wider in male cats compared with female cats, with differences frequently significant. The most significant difference was identified for the width of Mc5 (p = 0.0008) and the length and width of Mt5 (p = 0.0005). Index ratios for length and width of radius to metacarpal bones, and tibia to metatarsal bones, were not significantly different between male and female cats, except for Mc5. The index ratio for Mc5 was significantly higher in male cats (p = 0.002).Conclusion The present study provides insights into the normal length and width of distal forelimb and hind limb bones as well as bone index ratios in mature domestic shorthair cats. Using this information, it is now possible to quantitatively assess the relationship between these bones in domestic cats using radiography. This will assist not only with the diagnosis and categorization of skeletal abnormalities but can also guide surgical interventions of metacarpal and metatarsal bone fractures.
- 6 September 2021
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 34 (06) , 401-410
Feline Skeletal Reference Guide: A Cadaveric Radiographic Measurement on Lower Limb Extremities
Objective The aim of this study was to create a feline reference database for the length, width and slenderness (length to width ratio) of metacarpal and metatarsal bones, radius and tibia.Study Design Radiographs of the radius, tibia, metacarpus and metatarsus were performed in domestic short hair cat cadavers (n = 40). Length and width of the aforementioned bones were measured in mature domestic shorthair cats and bone slenderness (length/width) and index ratios calculated.Results A significant skeletal sex dimorphism exists in cats, with bones of the metacarpus, metatarsus, radius and tibia generally longer and wider in male cats compared with female cats, with differences frequently significant. The most significant difference was identified for the width of Mc5 (p = 0.0008) and the length and width of Mt5 (p = 0.0005). Index ratios for length and width of radius to metacarpal bones, and tibia to metatarsal bones, were not significantly different between male and female cats, except for Mc5. The index ratio for Mc5 was significantly higher in male cats (p = 0.002).Conclusion The present study provides insights into the normal length and width of distal forelimb and hind limb bones as well as bone index ratios in mature domestic shorthair cats. Using this information, it is now possible to quantitatively assess the relationship between these bones in domestic cats using radiography. This will assist not only with the diagnosis and categorization of skeletal abnormalities but can also guide surgical interventions of metacarpal and metatarsal bone fractures.
- 1 April 2019
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 80 (4) , 385-395
Hepatic computed tomography and cholangiography by use of gadoxetic acid in healthy cats
OBJECTIVE: To evaluate 3 doses of gadoxetic acid (Gd-EOB-DPTA) for hepatic CT and cholangiography in cats and to determine optimal timing for hepatobiliary image acquisition and evaluation of the contrast-enhanced hepatobiliary anatomy. ANIMALS: 6 healthy cats. PROCEDURES: Cats were anesthetized; sequential CT scans were performed 0, 5, 25, 45, 65, and 85 minutes after IV administration of Gd-EOB-DTPA at low (0.0125 mmol/kg), medium (0.1 mmol/kg), and high (0.3 mmol/kg) doses. Hepatobiliary enhancement for each dose was objectively assessed over time and by use of a subjective semiquantitative visual assessment score. RESULTS: No contrast-related adverse effects were detected. Each increase in dose of contrast medium resulted in a significant increase in HU across the hepatobiliary system. The liver had a significantly higher number of HU at 45 minutes, with homogenous enhancement at all doses of contrast medium. Contrast-enhanced cystic and bile duct HU were significantly higher and maximal at 65 minutes. Contrast-enhanced gallbladder HU did not plateau by 85 minutes. At a high dose of contrast medium, 12 of 60 (20%) biliary tract scores indicated no enhancement, 34 (57%) indicated poor enhancement, and 14 (23%) indicated moderate enhancement. No cat had excellent enhancement of the biliary tract at any dose. CONCLUSIONS AND CLINICAL RELEVANCE: Gd-EOB-DTPA–enhanced hepatic CT and cholangiography in cats were safely performed and provided good hepatic enhancement but poor to moderate enhancement of the biliary tract. This technique may be useful for assessing the liver parenchyma in cats, but its value for assessing the biliary tract is questionable.
- 1 April 2019
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 80 (4) , 385-395
Hepatic computed tomography and cholangiography by use of gadoxetic acid in healthy cats
OBJECTIVE: To evaluate 3 doses of gadoxetic acid (Gd-EOB-DPTA) for hepatic CT and cholangiography in cats and to determine optimal timing for hepatobiliary image acquisition and evaluation of the contrast-enhanced hepatobiliary anatomy. ANIMALS: 6 healthy cats. PROCEDURES: Cats were anesthetized; sequential CT scans were performed 0, 5, 25, 45, 65, and 85 minutes after IV administration of Gd-EOB-DTPA at low (0.0125 mmol/kg), medium (0.1 mmol/kg), and high (0.3 mmol/kg) doses. Hepatobiliary enhancement for each dose was objectively assessed over time and by use of a subjective semiquantitative visual assessment score. RESULTS: No contrast-related adverse effects were detected. Each increase in dose of contrast medium resulted in a significant increase in HU across the hepatobiliary system. The liver had a significantly higher number of HU at 45 minutes, with homogenous enhancement at all doses of contrast medium. Contrast-enhanced cystic and bile duct HU were significantly higher and maximal at 65 minutes. Contrast-enhanced gallbladder HU did not plateau by 85 minutes. At a high dose of contrast medium, 12 of 60 (20%) biliary tract scores indicated no enhancement, 34 (57%) indicated poor enhancement, and 14 (23%) indicated moderate enhancement. No cat had excellent enhancement of the biliary tract at any dose. CONCLUSIONS AND CLINICAL RELEVANCE: Gd-EOB-DTPA–enhanced hepatic CT and cholangiography in cats were safely performed and provided good hepatic enhancement but poor to moderate enhancement of the biliary tract. This technique may be useful for assessing the liver parenchyma in cats, but its value for assessing the biliary tract is questionable.
- Open Access
- 1 January 2019
- Published by SAGE Publications in Journal of Feline Medicine and Surgery Open Reports
- Vol. 5 (1)
Colonic malignant peripheral nerve sheath tumour in a cat
Case summary: A 14-year-old male neutered domestic mediumhair cat presented with a 4 month history of inappetence and weight loss. Pertinent abnormalities on haematology and biochemistry included a mild microcytic regenerative anaemia (packed cell volume [PCV] 24% [reference interval (RI) 30–45%], mean cell volume 30.8 fl [RI 40–45 fl], absolute reticulocyte count 326.8 × 1012) and increased alkaline phosphatase activity (76 IU/l; RI 300 s [RI 65–119 s]). Abdominal ultrasound identified multiple renal and hepatic nodules. Euthanasia was performed and post-mortem examination confirmed metastasis of the MPNST. Relevance and novel information: This report describes the treatment of a metastatic colonic peripheral nerve sheath tumour in a cat. Feline visceral MPNSTs are rare and little is known about prognosis or optimal treatment.
- 1 January 2019
- Published by SAGE Publications in Journal of Feline Medicine and Surgery Open Reports
- Vol. 5 (1)
Open AccessColonic malignant peripheral nerve sheath tumour in a cat
Case summary: A 14-year-old male neutered domestic mediumhair cat presented with a 4 month history of inappetence and weight loss. Pertinent abnormalities on haematology and biochemistry included a mild microcytic regenerative anaemia (packed cell volume [PCV] 24% [reference interval (RI) 30–45%], mean cell volume 30.8 fl [RI 40–45 fl], absolute reticulocyte count 326.8 × 1012) and increased alkaline phosphatase activity (76 IU/l; RI 300 s [RI 65–119 s]). Abdominal ultrasound identified multiple renal and hepatic nodules. Euthanasia was performed and post-mortem examination confirmed metastasis of the MPNST. Relevance and novel information: This report describes the treatment of a metastatic colonic peripheral nerve sheath tumour in a cat. Feline visceral MPNSTs are rare and little is known about prognosis or optimal treatment.
- 1 August 2018
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 79 (8) , 874-883
Effect of body position and time on quantitative computed tomographic measurements of lung volume and attenuation in healthy anesthetized cats
OBJECTIVE To quantify the effect of time and recumbency on CT measurements of lung volume and attenuation in healthy cats under general anesthesia. ANIMALS 8 healthy research cats. PROCEDURES Anesthetized cats were positioned in sternal recumbency for 20 minutes and then in left, right, and left lateral recumbency (40 minutes/position). Expiratory helical CT scan of the thorax was performed at 0 and 20 minutes in sternal recumbency and at 0, 5, 10, 20, 30, and 40 minutes in each lateral recumbent position. For each lung, CT measurements of lung volume and attenuation and the extent of lung areas that were hyperaerated (−1,000 to −901 Hounsfield units [HU]), normoaerated (−900 to −501 HU), poorly aerated (−500 to −101 HU), or nonaerated (−100 to +100 HU [indicative of atelectasis]) were determined with a semiautomatic threshold-based technique. A restricted maximum likelihood analysis was performed. RESULTS In lateral recumbency, the dependent lung had significantly greater attenuation and a lower volume than the nondependent lung. Within the dependent lung, there was a significantly higher percentage of poorly aerated lung tissue, compared with that in the nondependent lung. These changes were detected immediately after positioning the cats in lateral recumbency and remained static with no further significant time-related change. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that once anesthetized healthy cats were positioned in lateral recumbency, the dependent lung lobes underwent a rapid reduction in lung volume and increase in lung attenuation that did not progress over time, predominantly attributable to an increase in poorly aerated lung tissue.
- 1 August 2018
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 79 (8) , 874-883
Effect of body position and time on quantitative computed tomographic measurements of lung volume and attenuation in healthy anesthetized cats
OBJECTIVE To quantify the effect of time and recumbency on CT measurements of lung volume and attenuation in healthy cats under general anesthesia. ANIMALS 8 healthy research cats. PROCEDURES Anesthetized cats were positioned in sternal recumbency for 20 minutes and then in left, right, and left lateral recumbency (40 minutes/position). Expiratory helical CT scan of the thorax was performed at 0 and 20 minutes in sternal recumbency and at 0, 5, 10, 20, 30, and 40 minutes in each lateral recumbent position. For each lung, CT measurements of lung volume and attenuation and the extent of lung areas that were hyperaerated (−1,000 to −901 Hounsfield units [HU]), normoaerated (−900 to −501 HU), poorly aerated (−500 to −101 HU), or nonaerated (−100 to +100 HU [indicative of atelectasis]) were determined with a semiautomatic threshold-based technique. A restricted maximum likelihood analysis was performed. RESULTS In lateral recumbency, the dependent lung had significantly greater attenuation and a lower volume than the nondependent lung. Within the dependent lung, there was a significantly higher percentage of poorly aerated lung tissue, compared with that in the nondependent lung. These changes were detected immediately after positioning the cats in lateral recumbency and remained static with no further significant time-related change. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that once anesthetized healthy cats were positioned in lateral recumbency, the dependent lung lobes underwent a rapid reduction in lung volume and increase in lung attenuation that did not progress over time, predominantly attributable to an increase in poorly aerated lung tissue.
- Open Access
- 1 July 2018
- Published by SAGE Publications in Journal of Feline Medicine and Surgery Open Reports
- Vol. 4 (2)
Recanalisation of a congenital extrahepatic portosystemic shunt previously attenuated with cellophane banding in a cat
Case summary: A congenital extrahepatic portosystemic shunt was attenuated with commercial roll cellophane banding in a cat and postoperative liver changes were monitored using CT angiography (CTA). The patient clinically improved after cellophane banding, characterised by resolution of hepatic encephalopathy, weight gain, reference interval (RI) bile acid stimulation tests, as well as CTA-documented increased liver size, increased hepatic vasculature and shunt attenuation. Six months later the cat re-presented with recurrence of clinical signs and increased bile acids. CTA confirmed recanalisation of the shunt. Shunt attenuation was repeated using pure cellophane banding and nearly complete closure of the shunt was later documented by CTA. Seven months later, recanalisation was again documented via CTA and associated with clinical signs and increased bile acids. Complete ligation of the shunt was achieved using a polypropylene ligature and a titanium ligating clip. At long-term follow-up, the cat was clinically well, and bile acids and biochemistry were within the RIs. Relevance and novel information: This is the first report of CTA-documented recanalisation of an extrahepatic portosystemic shunt previously attenuated with cellophane banding. Recanalisation should be considered as a differential for recurrence of hepatic encephalopathy following cellophane banding.
- 1 July 2018
- Published by SAGE Publications in Journal of Feline Medicine and Surgery Open Reports
- Vol. 4 (2)
Open AccessRecanalisation of a congenital extrahepatic portosystemic shunt previously attenuated with cellophane banding in a cat
Case summary: A congenital extrahepatic portosystemic shunt was attenuated with commercial roll cellophane banding in a cat and postoperative liver changes were monitored using CT angiography (CTA). The patient clinically improved after cellophane banding, characterised by resolution of hepatic encephalopathy, weight gain, reference interval (RI) bile acid stimulation tests, as well as CTA-documented increased liver size, increased hepatic vasculature and shunt attenuation. Six months later the cat re-presented with recurrence of clinical signs and increased bile acids. CTA confirmed recanalisation of the shunt. Shunt attenuation was repeated using pure cellophane banding and nearly complete closure of the shunt was later documented by CTA. Seven months later, recanalisation was again documented via CTA and associated with clinical signs and increased bile acids. Complete ligation of the shunt was achieved using a polypropylene ligature and a titanium ligating clip. At long-term follow-up, the cat was clinically well, and bile acids and biochemistry were within the RIs. Relevance and novel information: This is the first report of CTA-documented recanalisation of an extrahepatic portosystemic shunt previously attenuated with cellophane banding. Recanalisation should be considered as a differential for recurrence of hepatic encephalopathy following cellophane banding.