Alfredo López-Muñoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alfredo López-Muñoz has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Marta C. García-Romera
Department of Physics of Condensed Matter, Optics Area. Vision Research Group (CIVIUS), University of Seville, Seville, Spain
5 shared publications - Úrsula Torres-Parejo
Department of Statistics and Operations Research, Faculty of Sciences, Campus Universitario de Fuente Nueva, University of Granada, Granada, Spain
4 shared publications - José-María Sánchez-González
Departament of Physics of Condensed Matter, Optics Area, Pharmacy Faculty, University of Seville, Seville, Spain
3 shared publications - Isabel López-Castaño
Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain
2 shared publications - Marta Romero-Luna
Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain
2 shared publications - Raúl Capote-Puente
Department of Physics of Condensed Matter, Optics Area, University of Seville, 41012 Seville, Spain
2 shared publications
Latest Publications
- Open Access
- 17 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7688
Effect of Exposure to Blue Light from Electronic Devices and the Mediterranean Diet on Macular Pigment
Objective: To explore the effect of time exposure to flat screen electronic devices with LED lighting and the Mediterranean diet on macular pigment optical density (MPOD). Methods: In this cross-sectional observational study, the MPOD was measured by heterochromatic flicker photometry in 164 eyes (47 of younger women aged 20–31 and 35 of older women aged 42–70). Exclusion criteria: evidence of macular degeneration and eyes with cataracts. Data on the use of electronic devices and Mediterranean diet adherence were collected through a survey. Nonparametric analysis of variance and independent sample t-tests were used to compare subjects. Results: Significant differences (p < 0.01) were found in total time of exposure to LEDs (hours per day) between both groups (9.31 ± 3.74 younger women vs. 6.33 ± 3.64 older women). The MPOD values for the younger and adult populations were significantly different: 0.38 ± 0.16 and 0.47 ± 0.15 (p < 0.01), respectively. When comparing both groups for the same time of exposure to LEDs, differences were obtained between MPOD values of both populations: For total exposures greater than 6 h per day, the MPOD values were lower in younger women than in adult ones (0.37 ± 0.14 vs. 0.50 ± 0.14, p < 0.01). On the other hand, a significantly higher adherence was found in the older women in comparison with the younger women (OW 9.23 ± 2.50 vs. YW 7.70 ± 2.08, p < 0.01), with higher MPOD values (OW (0.52 ± 0.14) vs. (YW (0.34 ± 0.18). Conclusions: Higher MPOD values are observed with decreasing exposure time to electronic devices with LED lighting screens and higher adherence to the Mediterranean diet.
- 17 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7688
Open AccessEffect of Exposure to Blue Light from Electronic Devices and the Mediterranean Diet on Macular Pigment
Objective: To explore the effect of time exposure to flat screen electronic devices with LED lighting and the Mediterranean diet on macular pigment optical density (MPOD). Methods: In this cross-sectional observational study, the MPOD was measured by heterochromatic flicker photometry in 164 eyes (47 of younger women aged 20–31 and 35 of older women aged 42–70). Exclusion criteria: evidence of macular degeneration and eyes with cataracts. Data on the use of electronic devices and Mediterranean diet adherence were collected through a survey. Nonparametric analysis of variance and independent sample t-tests were used to compare subjects. Results: Significant differences (p < 0.01) were found in total time of exposure to LEDs (hours per day) between both groups (9.31 ± 3.74 younger women vs. 6.33 ± 3.64 older women). The MPOD values for the younger and adult populations were significantly different: 0.38 ± 0.16 and 0.47 ± 0.15 (p < 0.01), respectively. When comparing both groups for the same time of exposure to LEDs, differences were obtained between MPOD values of both populations: For total exposures greater than 6 h per day, the MPOD values were lower in younger women than in adult ones (0.37 ± 0.14 vs. 0.50 ± 0.14, p < 0.01). On the other hand, a significantly higher adherence was found in the older women in comparison with the younger women (OW 9.23 ± 2.50 vs. YW 7.70 ± 2.08, p < 0.01), with higher MPOD values (OW (0.52 ± 0.14) vs. (YW (0.34 ± 0.18). Conclusions: Higher MPOD values are observed with decreasing exposure time to electronic devices with LED lighting screens and higher adherence to the Mediterranean diet.
- Open Access
- 19 September 2024
- Published by MDPI AG in Preprints.org
Effect of Exposure to Blue Light from Electronic Devices and the Mediterranean Diet on Macular Pigment
Objective: To explore the effect of time exposure to flat screen electronic devices with LED 14 lighting and the Mediterranean diet on macular pigment optical density (MPOD). Methods: MPOD 15 was measured by heterochromatic flicker photometry in 164 eyes (47 of young women 20-31 years 16 and 35 adult women 42-70 years). Exclusion criteria: evidence of macular degeneration and eyes 17 with cataracts. Data on the use of electronic devices and Mediterranean diet adherence were col- 18 lected through a survey. Nonparametric analysis of variance and independent sample t-tests were 19 used to compare subjects. Results: Significant differences (p<0.01) were found in total time of expo- 20 sure to LEDs (hours per day) between both groups (9.31 ± 3.74 young women vs 6.33 ± 3.64 old 21 women). The MPOD values for the young and adult populations were significantly different: 0.38 ± 22 0.16 and 0.47 ± 0.15 (p<0.01), respectively. When comparing both groups for the same time of expo- 23 sure to LEDs, differences were obtained between MPOD values of both populations: For total expo- 24 sures greater than 6 hours per day, the MPOD values were lower in young women than in adult 25 ones (0.37 ± 0.14 vs 0.50 ± 0.14, p<0.01). On the other hand, a significantly higher adherence was 26 found in the old women in comparison with the young women (OW 9.23± 2.50 vs YW 7.70 ± 2.08, 27 p<0.01), with higher MPOD values, (OW (0.52 ± 0.14) vs (YW (0.34 ± 0.18). Conclusions: Higher 28 MPOD values are observed with decreasing exposure time to electronic devices with LED lighting 29 screens and high adherence to the Mediterranean diet.
- 19 September 2024
- Published by MDPI AG in Preprints.org
Open AccessEffect of Exposure to Blue Light from Electronic Devices and the Mediterranean Diet on Macular Pigment
Objective: To explore the effect of time exposure to flat screen electronic devices with LED 14 lighting and the Mediterranean diet on macular pigment optical density (MPOD). Methods: MPOD 15 was measured by heterochromatic flicker photometry in 164 eyes (47 of young women 20-31 years 16 and 35 adult women 42-70 years). Exclusion criteria: evidence of macular degeneration and eyes 17 with cataracts. Data on the use of electronic devices and Mediterranean diet adherence were col- 18 lected through a survey. Nonparametric analysis of variance and independent sample t-tests were 19 used to compare subjects. Results: Significant differences (p<0.01) were found in total time of expo- 20 sure to LEDs (hours per day) between both groups (9.31 ± 3.74 young women vs 6.33 ± 3.64 old 21 women). The MPOD values for the young and adult populations were significantly different: 0.38 ± 22 0.16 and 0.47 ± 0.15 (p<0.01), respectively. When comparing both groups for the same time of expo- 23 sure to LEDs, differences were obtained between MPOD values of both populations: For total expo- 24 sures greater than 6 hours per day, the MPOD values were lower in young women than in adult 25 ones (0.37 ± 0.14 vs 0.50 ± 0.14, p<0.01). On the other hand, a significantly higher adherence was 26 found in the old women in comparison with the young women (OW 9.23± 2.50 vs YW 7.70 ± 2.08, 27 p<0.01), with higher MPOD values, (OW (0.52 ± 0.14) vs (YW (0.34 ± 0.18). Conclusions: Higher 28 MPOD values are observed with decreasing exposure time to electronic devices with LED lighting 29 screens and high adherence to the Mediterranean diet.
- Open Access
A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
Open AccessA Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
- Open Access
- 11 October 2023
- Published by MDPI AG in Preprints.org
Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyzer in Soft Contact Lens Wearers
The aim of this study was to evaluate the biomechanical changes of the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with the Corvis ST® analyzer. This prospective, cross-sectional, single-center study was performed in twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range). Five device-specific biomechanical parameters, central corneal thickness and intraocular pressure were measured prior to fitting and one month after CLs wear. Differences between the means of the DA Ratio and the standard deviation of the DA Ratio pre- and post-CLs wear were found to be significant (p value=0.002 in both cases). Significant differences were found between pre- and post-CLs wear values in CCT (p value=0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CLs wear in the assessment of bIOP.
- 11 October 2023
- Published by MDPI AG in Preprints.org
Open AccessCorneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyzer in Soft Contact Lens Wearers
The aim of this study was to evaluate the biomechanical changes of the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with the Corvis ST® analyzer. This prospective, cross-sectional, single-center study was performed in twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range). Five device-specific biomechanical parameters, central corneal thickness and intraocular pressure were measured prior to fitting and one month after CLs wear. Differences between the means of the DA Ratio and the standard deviation of the DA Ratio pre- and post-CLs wear were found to be significant (p value=0.002 in both cases). Significant differences were found between pre- and post-CLs wear values in CCT (p value=0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CLs wear in the assessment of bIOP.
- Open Access
Key Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology
The aim of this study was to evaluate the relationship between myopia and ocular biometric variables using the Pentacam AXL® single rotation Scheimpflug camera. This prospective, cross-sectional, single-center study was performed in fifty Caucasian patients aged between 18 and 30 years (24.84 ± 3.04 years). The measured variables included maximum and minimum keratometry (K1 and K2, respectively), anterior chamber depth (ACD), corneal horizontal diameter or white to white (WTW), central corneal thickness (CCT), corneal asphericity (Q), and axial length (AXL). The tomographic and biometric measurements were considered optimal when the quality factor was greater than 95% according to the manufacturer’s software instructions. The AXL presented a significant correlation with the spherical equivalent without cycloplegia (SE without CP), age at onset of myopia (r = −0.365, p = 0.012), mean keratometry (Km) (r = −0.339, p = 0.016), ACD (r = 0.304, p = 0.032), and WTW (r = 0.406, p = 0.005). The eyes with AXL higher than 25 mm had earlier onset; higher SE without CP, AXL, and Q; and a flatter Km. AXL is the biometric variable with the greatest influence on the final refractive state in the adult myopic eye. Ophthalmologists and optometric management must consider these biometric differences in order to identify the most appropriate correction techniques in each case. The use of the Pentacam AXL in ocular biometric measurement is effective, reproducible, and non-invasive.
Open AccessKey Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology
The aim of this study was to evaluate the relationship between myopia and ocular biometric variables using the Pentacam AXL® single rotation Scheimpflug camera. This prospective, cross-sectional, single-center study was performed in fifty Caucasian patients aged between 18 and 30 years (24.84 ± 3.04 years). The measured variables included maximum and minimum keratometry (K1 and K2, respectively), anterior chamber depth (ACD), corneal horizontal diameter or white to white (WTW), central corneal thickness (CCT), corneal asphericity (Q), and axial length (AXL). The tomographic and biometric measurements were considered optimal when the quality factor was greater than 95% according to the manufacturer’s software instructions. The AXL presented a significant correlation with the spherical equivalent without cycloplegia (SE without CP), age at onset of myopia (r = −0.365, p = 0.012), mean keratometry (Km) (r = −0.339, p = 0.016), ACD (r = 0.304, p = 0.032), and WTW (r = 0.406, p = 0.005). The eyes with AXL higher than 25 mm had earlier onset; higher SE without CP, AXL, and Q; and a flatter Km. AXL is the biometric variable with the greatest influence on the final refractive state in the adult myopic eye. Ophthalmologists and optometric management must consider these biometric differences in order to identify the most appropriate correction techniques in each case. The use of the Pentacam AXL in ocular biometric measurement is effective, reproducible, and non-invasive.
- Open Access
Rigid Gas-Permeable Semi-Scleral Contact Lenses after Radial Keratotomy: Apical Space, Lens Diameter, Limbal Clearance, Peripheral O-Rings, and Tear Exchange as Contact-Lens-Fitting Success Factors
The purpose of this case report is to verify if the adaptation of a rigid gas-permeable contact lens can improve VA and comfort in a patient with complications derived from radial keratotomy (RK) surgery. A semi-scleral contact lens was fitted in a 46-year-old female patient who had undergone bilateral RK before 30 years. The uncorrected distance visual acuity in the right eye (RE) and left eye (LE) was 0.5 and 0.6 logMAR (minimum angle resolution), respectively. The RE and LE manifest refractions were +2.00 − 4.25 × 155 diopters (D) and +2.00 − 3.00 × 15 D, respectively. A semi-scleral rigid gas-permeable Rose K2 XL™ lens was fitted in both eyes. The central clearance was 400–450 µm in the RE and 300–350 µm in the LE. The semi-scleral corrected distance visual acuity in the RE and LE was 0.1 and 0.16 logMAR, respectively. Semi-scleral contact lenses are comfortable and a beneficial choice for patients after RK when associated with visual problems and intolerance to other therapeutic options. Semi-scleral lenses permit prolonged duration of use without discomfort, adverse alterations, and improve the feeling of glare in scotopic vision. In the present case, there were multiple factors that influenced the resolution, such as the amount of apical space, lens diameter, limbal clearance, peripheral O-rings, and tear exchange.
Open AccessRigid Gas-Permeable Semi-Scleral Contact Lenses after Radial Keratotomy: Apical Space, Lens Diameter, Limbal Clearance, Peripheral O-Rings, and Tear Exchange as Contact-Lens-Fitting Success Factors
The purpose of this case report is to verify if the adaptation of a rigid gas-permeable contact lens can improve VA and comfort in a patient with complications derived from radial keratotomy (RK) surgery. A semi-scleral contact lens was fitted in a 46-year-old female patient who had undergone bilateral RK before 30 years. The uncorrected distance visual acuity in the right eye (RE) and left eye (LE) was 0.5 and 0.6 logMAR (minimum angle resolution), respectively. The RE and LE manifest refractions were +2.00 − 4.25 × 155 diopters (D) and +2.00 − 3.00 × 15 D, respectively. A semi-scleral rigid gas-permeable Rose K2 XL™ lens was fitted in both eyes. The central clearance was 400–450 µm in the RE and 300–350 µm in the LE. The semi-scleral corrected distance visual acuity in the RE and LE was 0.1 and 0.16 logMAR, respectively. Semi-scleral contact lenses are comfortable and a beneficial choice for patients after RK when associated with visual problems and intolerance to other therapeutic options. Semi-scleral lenses permit prolonged duration of use without discomfort, adverse alterations, and improve the feeling of glare in scotopic vision. In the present case, there were multiple factors that influenced the resolution, such as the amount of apical space, lens diameter, limbal clearance, peripheral O-rings, and tear exchange.
- Open Access
- 23 June 2022
- Published by Elsevier in Physiology & Behavior
- Vol. 254, 113891
Effect of macular pigment carotenoids on cognitive functions: A systematic review
- 23 June 2022
- Published by Elsevier in Physiology & Behavior
- Vol. 254, 113891
Open AccessEffect of macular pigment carotenoids on cognitive functions: A systematic review
- 1 November 2019
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 35 (11) , 740-747
Complications and Explantation Reasons in Intracorneal Ring Segments (ICRS) Implantation: A Systematic Review
PURPOSE: To review the intraoperative and postoperative complications after intracorneal ring segment implantation and to report the explantation rate among the available scientific literature. METHODS: Three different databases (PubMed, Web of Science, and Scopus) were assessed from January 1995 to June 2019. The keywords used were: ring, rings, ICRS (intracorneal ring segments), segment, segments or Intacs, complication, explantation, explanted, retired, and removal. RESULTS: The selection process of this systematic review study is described in a flow diagram. A total of 39 studies published between 1995 and 2019 were included. Sixteen studies were case reports, 21 were case series studies, and 2 were chart analysis works. This study enrolled 1,946 participants, and 2,590 eyes were included. The postoperative complications described in most studies included migration, ring extrusion, corneal thinning, corneal melting, and some type of infective keratitis. These complications together with glare, halos, fluctuating vision, neovascularization, foreign body sensation, or pain represented most of the causes. The percentage rate of explantation ranged from 0.5% up to 83.3%. If we analyze those articles with a high number of implantations (2,124 eyes), an explantation rate between 0% and 1.4% was obtained. CONCLUSIONS: The complication rate and explantation ratio in segments of the intracorneal ring segments analyzed in the available scientific literature are minimal. Therefore, patient selection, surgery planning, and postoperative follow-up are critical to the success of surgery. [ J Refract Surg . 2019;35(11):740–747.]
- 1 November 2019
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 35 (11) , 740-747
Complications and Explantation Reasons in Intracorneal Ring Segments (ICRS) Implantation: A Systematic Review
PURPOSE: To review the intraoperative and postoperative complications after intracorneal ring segment implantation and to report the explantation rate among the available scientific literature. METHODS: Three different databases (PubMed, Web of Science, and Scopus) were assessed from January 1995 to June 2019. The keywords used were: ring, rings, ICRS (intracorneal ring segments), segment, segments or Intacs, complication, explantation, explanted, retired, and removal. RESULTS: The selection process of this systematic review study is described in a flow diagram. A total of 39 studies published between 1995 and 2019 were included. Sixteen studies were case reports, 21 were case series studies, and 2 were chart analysis works. This study enrolled 1,946 participants, and 2,590 eyes were included. The postoperative complications described in most studies included migration, ring extrusion, corneal thinning, corneal melting, and some type of infective keratitis. These complications together with glare, halos, fluctuating vision, neovascularization, foreign body sensation, or pain represented most of the causes. The percentage rate of explantation ranged from 0.5% up to 83.3%. If we analyze those articles with a high number of implantations (2,124 eyes), an explantation rate between 0% and 1.4% was obtained. CONCLUSIONS: The complication rate and explantation ratio in segments of the intracorneal ring segments analyzed in the available scientific literature are minimal. Therefore, patient selection, surgery planning, and postoperative follow-up are critical to the success of surgery. [ J Refract Surg . 2019;35(11):740–747.]
- 11 November 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 37 (6) , 1263-1268
Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction
To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p < 0.001). Statistically significant differences were found between men and women for the total area (p = 0.006), with readings of 16.22 ± 1.54 GSU and 16.60 ± 1.83 GSU, respectively. When the cornea was divided into layers of different depths, a significant correlation was found for all layers and age: r = 0.447 (p < 0.001), r = 0.563 (p < 0.001), and r = 0.520 (p < 0.001) for the anterior, central, and posterior layers, respectively. However, when the cornea was divided into concentric annuli starting from the center of the cornea, densitometry was strongly correlated only with age in the 6–10-mm annulus (p < 0.001). Neither mean keratometry nor spherical equivalent was correlated with corneal densitometry in any zone of the cornea (p > 0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.
- 11 November 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 37 (6) , 1263-1268
Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction
To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p < 0.001). Statistically significant differences were found between men and women for the total area (p = 0.006), with readings of 16.22 ± 1.54 GSU and 16.60 ± 1.83 GSU, respectively. When the cornea was divided into layers of different depths, a significant correlation was found for all layers and age: r = 0.447 (p < 0.001), r = 0.563 (p < 0.001), and r = 0.520 (p < 0.001) for the anterior, central, and posterior layers, respectively. However, when the cornea was divided into concentric annuli starting from the center of the cornea, densitometry was strongly correlated only with age in the 6–10-mm annulus (p < 0.001). Neither mean keratometry nor spherical equivalent was correlated with corneal densitometry in any zone of the cornea (p > 0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.