HLHaoyan Li

Haoyan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haoyan Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Yun Peng

    Department of Radiology, MOE Key Laboratory of Major Diseases in Children, Beijing Children’s Hospital, Capital Medical University, National Center for Children’s Health, China

    6 shared publications
  • Jihang Sun

    Department of Radiology, Beijing Children’s Hospital, Capital Medical University, National Center for Children’s Health, Beijing, China

    5 shared publications
  • Bei Wang

    Department of radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No.56, Nanlishi Road, Xicheng District, Beijing 100045, China

    2 shared publications
  • Jianying Li

    CT Research, GE Healthcare, Dalian, China

    2 shared publications
  • Michelle Li

    Stanford University, Stanford, USA

    2 shared publications
  • Ruifang Sun

    Department of radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No.56, Nanlishi Road, Xicheng District, Beijing 100045, China

    2 shared publications

Latest Publications

  • Open Access

    Feasibility of single-phase DECT as an alternative to triple-phase CT for imaging-defined risk factors assessment in neuroblastoma for dose reduction

    by Ruifang Sun, Haoyan Li, Bei Wang, Huiying Kang, Runtong Lu, Zhenpeng Chen, Yun Peng, Jihang Sun

  • Improving Image Quality of Thin‐Slice and Low‐ keV Images in Dual‐Energy CT Angiography for Children With Neuroblastoma Using Deep Learning Image Reconstruction

    by Jihang Sun, Haoyan Li, Shen Yang, Ruifang Sun, Fanning Wang, Zhenpeng Chen, Yun Peng

    Neuroblastoma (NB) is a common malignant tumor in children, and the evaluation of vascular involvement image‐defined risk factors (IDRFs) using computed tomography angiography (CTA) is crucial for prognostic assessment. To evaluate whether deep learning image reconstruction (DLIR) can improve the image quality of thin‐slice, low‐keV images in dual‐energy CTA (DECTA) and provide a more accurate assessment of IDRFs in children with NB. Forty‐three NB patients (median age: 2 years., 6 months to 7 years), who underwent chest or abdominal DECTA , were included. The 0.625 mm slice thickness images at 40 keV were reconstructed using high‐strength DLIR (40 keV ‐ DL ‐0.6 mm) in the study group. The 0.625 mm images at 40 keV and 5 mm images at 68 keV , reconstructed using the adaptive statistical iterative reconstruction‐V ( ASIR ‐V) with a strength of 50% (40 keV ‐ AV ‐0.6 mm,68 keV ‐ AV ‐5 mm, respectively), served as the control group. Objective measurements included the contrast‐to‐noise ratio ( CNR ) and edge‐rise slope ( ERS ) of the aorta, and magnitude of noise power spectrum ( NPS ) of the liver. Subjective image quality was assessed using a 5‐point scale to evaluate overall image noise, image contrast, and the visualization of large and small arteries. The IDRFs were also evaluated across all images. In general, the 0.625‐mm images had higher spatial resolution and more confident IDRF assessment compared to the 5‐mm images. The 40 keV‐DL‐0.6‐mm images demonstrated the highest CNR and ERS of large vessels, and the best visualization of small arteries among the three image groups (all p < 0.05). Subjective assessments revealed that only the 40 keV‐DL‐0.6 mm images met diagnostic requirements for overall noise, image contrast, large artery, and small artery visualization simultaneously. DLIR‐H significantly improves the image quality of the thin‐slice and low‐keV images in DECTA for pediatric NB patients, enabling improved visualization of small arteries and more accurate assessment of vascular involvement IDRFs in NB.

  • Open Access

    Performance Evaluation of Image Segmentation Using Dual-Energy Spectral CT Images with Deep Learning Image Reconstruction: A Phantom Study

    by Haoyan Li, Zhenpeng Chen, Shuaiyi Gao, Jiaqi Hu, Zhihao Yang, Yun Peng, Jihang Sun

    Objectives: To evaluate the medical image segmentation performance of monochromatic images in various energy levels. Methods: The low-density module (25 mm in diameter, 6 Hounsfield Unit (HU) in density difference from background) from the ACR464 phantom was scanned at both 10 mGy and 5 mGy dose levels. Virtual monoenergetic images (VMIs) at different energy levels of 40, 50, 60, 68, 74, and 100 keV were generated. The images at 10 mGy reconstructed with 50% adaptive statistical iterative reconstruction veo (ASIR-V50%) were used to train an image segmentation model based on U-Net. The evaluation set used 5 mGy VMIs reconstructed with various reconstruction algorithms: FBP, ASIR-V50%, ASIR-V100%, deep learning image reconstruction (DLIR) with low (DLIR-L), medium (DLIR-M), and high (DLIR-H) strength levels. U-Net was employed as a tool to compare algorithm performance. Image noise and segmentation metrics, such as the DICE coefficient, intersection over union (IOU), sensitivity, and Hausdorff distance, were calculated to assess both image quality and segmentation performance. Results: DLIR-M and DLIR-H consistently achieved lower image noise and better segmentation performance, with the highest results observed at 60 keV, and DLIR-H had the lowest image noise across all energy levels. The performance metrics, including IOU, DICE, and sensitivity, were ranked in descending order with energy levels of 60 keV, 68 keV, 50 keV, 74 keV, 40 keV, and 100 keV. Specifically, at 60 keV, the average IOU values for each reconstruction method were 0.60 for FBP, 0.67 for ASIR-V50%, 0.68 for ASIR-V100%, 0.72 for DLIR-L, 0.75 for DLIR-M, and 0.75 for DLIR-H. The average DICE values were 0.75, 0.80, 0.82, 0.83, 0.85, and 0.86. The sensitivity values were 0.93, 0.91, 0.96, 0.95, 0.98, and 0.98. Conclusions: For low-density, non-enhancing objects under a low dose, the 60 keV VMIs performed better in automatic segmentation. DLIR-M and DLIR-H algorithms delivered the best results, whereas DLIR-H provided the lowest image noise and highest sensitivity.


  • Open Access

    Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection

    by Jihang Sun, Haoyan Li, Bei Wang, Jianying Li, Michelle Li, Zuofu Zhou, Yun Peng

    Background: To evaluate the performance of a Deep Learning Image Reconstruction (DLIR) algorithm in pediatric head CT for improving image quality and lesion detection with 0.625 mm thin-slice images. Methods: Low-dose axial head CT scans of 50 children with 120 kV, 0.8 s rotation and age-dependent 150–220 mA tube current were selected. Images were reconstructed at 5 mm and 0.625 mm slice thickness using Filtered back projection (FBP), Adaptive statistical iterative reconstruction-v at 50% strength (50%ASIR-V) (as reference standard), 100%ASIR-V and DLIR-high (DL-H). The CT attenuation and standard deviation values of the gray and white matters in the basal ganglia were measured. The clarity of sulci/cisterns, boundary between white and gray matters, and overall image quality was subjectively evaluated. The number of lesions in each reconstruction group was counted. Results: The 5 mm FBP, 50%ASIR-V, 100%ASIR-V and DL-H images had a subjective score of 2.25 ± 0.44, 3.05 ± 0.23, 2.87 ± 0.39 and 3.64 ± 0.49 in a 5-point scale, respectively with DL-H having the lowest image noise of white matter at 2.00 ± 0.34 HU; For the 0.625 mm images, only DL-H images met the diagnostic requirement. The 0.625 mm DL-H images had similar image noise (3.11 ± 0.58 HU) of the white matter and overall image quality score (3.04 ± 0.33) as the 5 mm 50% ASIR-V images (3.16 ± 0.60 HU and 3.05 ± 0.23). Sixty-five lesions were recognized in 5 mm 50%ASIR-V images and 69 were detected in 0.625 mm DL-H images. Conclusion: DL-H improves the head CT image quality for children compared with ASIR-V images. The 0.625 mm DL-H images improve lesion detection and produce similar image noise as the 5 mm 50%ASIR-V images, indicating a potential 85% dose reduction if current image quality and slice thickness are desired.


  • Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in “double low” chest CTA in children: a feasibility study

    by Jihang Sun, Haoyan Li, Jun Gao, Jianying Li, Michelle Li, Zuofu Zhou, Yun Peng

    Background Chest CT angiography (CTA) is a convenient clinical examination for children with an increasing need to reduce both radiation and contrast medium doses. Iterative Reconstruction algorithms are often used to reduce image noise but encounter limitations under low radiation dose and conventional 100 kVp tube voltage may not provide adequate enhancement under low contrast dose. Purpose To evaluate the performance of a deep learning image reconstruction (DLIR) algorithm in conjunction with lower tube voltage in chest CTA in children under reduced radiation and contrast medium (CM) dose. Materials and methods 46 Children (age 5.9 ± 4.2 years) in the study group underwent chest CTA with 70 kVp and CM dose of 0.8–1.2 ml/kg. Images were reconstructed at 0.625 mm using a high setting DLIR (DLIR-H). The control group consisted of 46 age-matching children scanned with 100 kVp, CM dose of 1.3–1.8 ml/kg and images reconstructed with 50% and 100% adaptive statistical iterative reconstruction-V. Two radiologists evaluated images subjectively for overall image noise, vessel contrast and vessel margin clarity separately on a 5-point scale (5, excellent and 1, not acceptable). CT value and image noise of aorta and erector spinae muscle were measured. Results Compared to the control group, the study group reduced the dose-length-product by 11.2% (p = 0.01) and CM dose by 24% (p < 0.001), improved the enhancement in aorta (416.5 ± 113.1HU vs. 342.0 ± 57.6HU, p < 0.001) and reduced noise (15.1 ± 3.5HU vs. 18.6 ± 4.4HU, p < 0.001). The DLIR-H images provided acceptable scores on all 3 aspects of the qualitative evaluation. Conclusion “Double low” chest CTA in children using 70 kVp and DLIR provides high image quality with reduced noise and improved vessel enhancement for diagnosis while further reduces radiation and CM dose.