ENEdward H. Nieh

Edward H. Nieh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edward H. Nieh has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Calcium Oscillations Within Juxtaglomerular Cell Clusters Control Renin Release

    by Hiroki Yamaguchi, Nick A. Guagliardo, Laura A. Bell, Manako Yamaguchi, Daisuke Matsuoka, Fang Xu, Jason P. Smith, Mohamed Diagne, Sophie Condron, Lucas F. Almeida, et al.

    BACKGROUND: Juxtaglomerular cells are sensors that control blood pressure and fluid-electrolyte homeostasis. They are arranged as clusters at the tip of each afferent arteriole. In response to decreased blood pressure or extracellular fluid volume, juxtaglomerular cells secrete renin, initiating an enzymatic cascade that culminates in the production of Ang II (angiotensin II), a potent vasoconstrictor that restores blood pressure and fluid-electrolyte homeostasis. In turn, Ang II exerts negative feedback on renin release commensurate with increased intracellular Ca 2+ , preventing excessive circulating renin and hypertension. However, within their native structural organization, the intricacies of intracellular Ca 2+ signaling dynamics and their sources remain uncharacterized. METHODS: We generated mice expressing the juxtaglomerular cell-specific genetically encoded Ca 2+ indicator (GCaMP6f) to investigate Ca 2+ dynamics within juxtaglomerular cell clusters ex vivo and in vivo. For ex vivo Ca 2+ imaging, acutely prepared kidney slices were perfused continuously with a buffer containing variable Ca 2+ and Ang II concentrations ±Ca 2+ channel inhibitors. For in vivo Ca 2+ image capture, native mouse kidneys were imaged in situ using multiphoton microscopy with and without Ang II and Ang II type-1 receptor blocker losartan administration. ELISA measurements determined acute renin secretion ex vivo and in vivo. RESULTS: Ex vivo Ca 2+ imaging revealed that juxtaglomerular cell clusters exhibit robust and coordinated intracellular oscillatory signals with cell-cell propagation following Ang II stimulation. Ang II dose-dependently induced stereotypical burst patterns characterized by consecutive Ca 2+ spikes, which inversely correlated with renin secretion. Pharmacological channel inhibition identified key sources of these oscillations: endoplasmic reticulum Ca 2+ storage and release, extracellular Ca 2+ uptake via store-operated ORAI (Ca 2+ -selective plasma membrane channels involved in store-operated Ca 2+ entry) Ca 2+ channels, and intercellular communication through gap junctions. Blocking ORAI channels and gap junctions reduced Ang II inhibitory effect on renin secretion. In vivo Ca 2+ imaging demonstrated robust intracellular and intercellular Ca 2+ oscillations within juxtaglomerular cell clusters under physiological conditions, exhibiting spike patterns consistent with those measured in ex vivo preparations. Ang II administration enhanced the Ca 2+ oscillatory signals and suppressed acute renin secretion, whereas losartan produced inverse effects in vivo. CONCLUSIONS: Ang II elicits coordinated intracellular and intercellular Ca 2+ oscillations within juxtaglomerular cell clusters, ex vivo and in vivo. The effect is driven by endoplasmic reticulum-derived Ca 2+ release, ORAI channels, and gap junctions, leading to suppressed renin secretion.


  • Open Access

    TWINKLE: An open-source two-photon microscope for teaching and research

    by Manuel Schottdorf, P. Dylan Rich, E. Mika Diamanti, Albert Lin, Sina Tafazoli, Edward H. Nieh, Stephan Y. Thiberge

    Many laboratories use two-photon microscopy through commercial suppliers, or homemade designs of considerable complexity. The integrated nature of these systems complicates customization, troubleshooting, and training on the principles of two-photon microscopy. Here, we present “Twinkle”: a microscope for Two-photon Imaging in Neuroscience, and Kit for Learning and Education. It is a fully open, high performing and easy-to-set-up microscope that can effectively be used for both education and research. The instrument features a >1 mm field of view, using a modern objective with 3 mm working distance and 2 inch diameter optics combined with GaAsP photomultiplier tubes to maximize the fluorescence signal. We document our experiences using this system as a teaching tool in several two week long workshops, exemplify scientific use cases, and conclude with a broader note on the place of our work in the growing space of open scientific instrumentation.


  • Open Access

    Inhibition of Renin Release, a Crucial Event in Homeostasis, is Mediated by Coordinated Calcium Oscillations within Juxtaglomerular Cell Clusters

    by Hiroki Yamaguchi, Nick A. Guagliardo, Laura A. Bell, Manako Yamaguchi, Daisuke Matsuoka, Fang Xu, Jason P. Smith, Mohamed Diagne, Lucas F. Almeida, Silvia Medrano, et al.

    BACKGROUND: Juxtaglomerular (JG) cells are sensors that control blood pressure (BP) and fluid-electrolyte homeostasis. They are arranged as clusters at the tip of each afferent arteriole. In response to a decrease in BP or extracellular fluid volume, JG cells secrete renin, initiating an enzymatic cascade that culminates in the production of angiotensin II (AngII), a potent vasoconstrictor that restores BP and fluid-electrolyte homeostasis. In turn, AngII exerts negative feedback on renin release concomitantly with increased intracellular Ca 2+ , preventing excessive circulating renin and hypertension. However, within their native structural organization, the intricacies of intracellular Ca 2+ signaling dynamics and their sources remain uncharacterized. METHODS: We generated mice expressing the JG cell-specific genetically encoded Ca 2+ indicator (GCaMP6f) to investigate Ca 2+ dynamics within JG cell clusters ex vivo and in vivo . For ex vivo Ca 2+ imaging, acutely prepared kidney slices were perfused continuously with a buffer containing variable Ca 2+ and AngII concentrations ± Ca 2+ channel inhibitors. For in vivo Ca 2+ image capture, native mouse kidneys were imaged in situ using multi-photon microscopy with and without AngII administration. ELISA measurements of renin concentrations determined acute renin secretion ex vivo and in vivo , respectively. RESULTS: Ex vivo Ca 2+ imaging revealed that JG cells exhibit robust and coordinated intracellular oscillatory signals with cell-cell propagation following AngII stimulation. AngII dose-dependently induced stereotypical burst patterns characterized by consecutive Ca 2+ spikes, which inversely correlated with renin secretion. Pharmacological channel inhibition identified key sources of these oscillations: endoplasmic reticulum Ca 2+ storage and release, extracellular Ca 2+ uptake via ORAI channels, and intercellular communication through gap junctions. Blocking ORAI channels and gap junctions reduced AngII inhibitory effect on renin secretion. In vivo Ca 2+ imaging demonstrated robust intracellular and intercellular Ca 2+ oscillations within JG cell clusters under physiological conditions, exhibiting spike patterns consistent with those measured in ex vivo preparations. Administration of AngII enhanced the Ca 2+ oscillatory signals and suppressed acute renin secretion in vivo . CONCLUSION: AngII elicits coordinated intracellular and intercellular Ca 2+ oscillations within JG cell clusters, ex vivo and in vivo . The effect is driven by endoplasmic reticulum-derived Ca 2+ release, ORAI channels, and gap junctions, leading to suppressed renin secretion.


  • Open Access

    TWINKLE: An open-source two-photon microscope for teaching and research

    by Manuel Schottdorf, P. Dylan Rich, E. Mika Diamanti, Albert Lin, Sina Tafazoli, Edward H. Nieh, Stephan Y. Thiberge

    Many laboratories use two-photon microscopy through commercial suppliers, or homemade designs of considerable complexity. The integrated nature of these systems complicates customization, troubleshooting, and training on the principles of two-photon microscopy. Here, we present "Twinkle": a microscope for Two-photon Imaging in Neuroscience, and Kit for Learning and Education. It is a fully open, high performing and easy-to-set-up microscope that can effectively be used for both education and research. The instrument features a > 1 mm field of view, using a modern objective with 3 mm working distance and 2 inch diameter optics combined with GaAsP photomultiplier tubes to maximize the fluorescence signal. We document our experiences using this system as a teaching tool in several two week long workshops, exemplify scientific use cases, and conclude with a broader note on the place of our work in the growing space of open scientific instrumentation.

  • Detecting and correcting false transients in calcium imaging

    by Jeffrey L. Gauthier, Sue Ann Koay, Edward H. Nieh, David W. Tank, Jonathan W. Pillow, Adam S. Charles

    Population recordings of calcium activity are a major source of insight into neural function. Large datasets require automated processing, but this can introduce errors that are difficult to detect. Here we show that popular time course-estimation algorithms often contain substantial misattribution errors affecting 10–20% of transients. Misattribution, in which fluorescence is ascribed to the wrong cell, arises when overlapping cells and processes are imperfectly defined or not identified. To diagnose misattribution, we develop metrics and visualization tools for evaluating large datasets. To correct time courses, we introduce a robust estimator that explicitly accounts for contaminating signals. In one hippocampal dataset, removing contamination reduced the number of place cells by 15%, and 19% of place fields shifted by over 10 cm. Our methods are compatible with other cell-finding techniques, empowering users to diagnose and correct a potentially widespread problem that could alter scientific conclusions.


  • Top Cited Papers

    Geometry of abstract learned knowledge in the hippocampus

    by Edward H. Nieh, Manuel Schottdorf, Nicolas W. Freeman, Ryan J. Low, Sam Lewallen, Sue Ann Koay, Lucas Pinto, Jeffrey L. Gauthier, Carlos D. Brody, David W. Tank

    Hippocampal neurons encode physical variables1,2,3,4,5,6,7 such as space1 or auditory frequency6 in cognitive maps8. In addition, functional magnetic resonance imaging studies in humans have shown that the hippocampus can also encode more abstract, learned variables9,10,11. However, their integration into existing neural representations of physical variables12,13 is unknown. Here, using two-photon calcium imaging, we show that individual neurons in the dorsal hippocampus jointly encode accumulated evidence with spatial position in mice performing a decision-making task in virtual reality14,15,16. Nonlinear dimensionality reduction13 showed that population activity was well-described by approximately four to six latent variables, which suggests that neural activity is constrained to a low-dimensional manifold. Within this low-dimensional space, both physical and abstract variables were jointly mapped in an orderly manner, creating a geometric representation that we show is similar across mice. The existence of conjoined cognitive maps suggests that the hippocampus performs a general computation—the creation of task-specific low-dimensional manifolds that contain a geometric representation of learned knowledge.