Heather A. Colburn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Heather A. Colburn has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Angela M. Melville
Chemical and Biological Signature Sciences, National Security Directorate, Pacific Northwest National Laboratory, P.O. Box 999, MSIN P7-50, Richland WA, 99352
5 shared publicationsKaren L. Wahl
Chemical and Biological Signature Sciences, National Security Directorate, Pacific Northwest National Laboratory, P.O. Box 999, MSIN P7-50, Richland WA, 99352
5 shared publicationsKathryn C. Antolick
Chemical and Biological Signature Sciences, National Security Directorate, Pacific Northwest National Laboratory, P.O. Box 999, MSIN P7-50, Richland WA, 99352
5 shared publicationsDavid S. Wunschel
4 shared publications- David S. Wunschel
Pacific Northwest National Laboratory, Richland, WA, USA
4 shared publications Jon H. Wahl
Chemical and Biological Signature Sciences, National Security Directorate, Pacific Northwest National Laboratory, P.O. Box 999, MSIN P7-50, Richland WA, 99352
4 shared publications
Latest Publications
- Open Access
- 13 December 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6  (51) , 35457-35466
On-Line Raman Measurement of the Radiation-Enhanced Reaction of Cellobiose with Hydrogen Peroxide
Production of a chemical feedstock as a secondary product from a commercial nuclear reactor can increase the economic viability of the reactor and enable the deployment of nuclear energy as part of the low-carbon energy grid. Currently, commercial nuclear reactors produce underutilized energy in the form of neutrons and gamma photons. This excess energy can be exploited to drive chemical reactions, increasing the fraction of utilized energy in reactors and providing a valuable secondary product from the reactor. Gamma degradation of cellulosic biomass has been studied previously. However, real-time, on-line monitoring of the breakdown of biomass materials under gamma radiation has not been demonstrated. Here, we demonstrate on-line monitoring of the reaction of cellobiose with hydrogen peroxide under gamma radiation using Raman spectroscopy, providing in situ quantification of organic and inorganic system components.
- 13 December 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6  (51) , 35457-35466
Open AccessOn-Line Raman Measurement of the Radiation-Enhanced Reaction of Cellobiose with Hydrogen Peroxide
Production of a chemical feedstock as a secondary product from a commercial nuclear reactor can increase the economic viability of the reactor and enable the deployment of nuclear energy as part of the low-carbon energy grid. Currently, commercial nuclear reactors produce underutilized energy in the form of neutrons and gamma photons. This excess energy can be exploited to drive chemical reactions, increasing the fraction of utilized energy in reactors and providing a valuable secondary product from the reactor. Gamma degradation of cellulosic biomass has been studied previously. However, real-time, on-line monitoring of the breakdown of biomass materials under gamma radiation has not been demonstrated. Here, we demonstrate on-line monitoring of the reaction of cellobiose with hydrogen peroxide under gamma radiation using Raman spectroscopy, providing in situ quantification of organic and inorganic system components.
- 1 July 2021
- Published by Office of Scientific and Technical Information (OSTI)
Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107
At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described.1 This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Csmore » concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (Kd) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this Kd corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics. « less
- 1 July 2021
- Published by Office of Scientific and Technical Information (OSTI)
Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107
At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described.1 This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Csmore » concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (Kd) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this Kd corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics. « less
- 1 December 2020
- Published by Office of Scientific and Technical Information (OSTI)
Radiation-Induced Catalysis of Chemical Reactions
Summary of accomplishments from this EED seed LDRD for FY2020.
- 1 December 2020
- Published by Office of Scientific and Technical Information (OSTI)
Radiation-Induced Catalysis of Chemical Reactions
Summary of accomplishments from this EED seed LDRD for FY2020.
- Open Access
- 31 August 2020
- Published by Office of Scientific and Technical Information (OSTI)
Small-Scale Drying: FY2020 Interim Report
This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.
- 31 August 2020
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessSmall-Scale Drying: FY2020 Interim Report
This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.
- Open Access
- 1 August 2019
- Published by Office of Scientific and Technical Information (OSTI)
Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media
The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar mediamore » under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): • CST in water at 25°C tested to 300 Mrad total dose • wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose • dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose • CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose • CST in 5.6M Na simulant with 1% (w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per-component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST-in-water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test. « less
- 1 August 2019
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessGas Generation Testing of Crystalline Silicotitanate Ion Exchange Media
The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar mediamore » under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): • CST in water at 25°C tested to 300 Mrad total dose • wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose • dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose • CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose • CST in 5.6M Na simulant with 1% (w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per-component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST-in-water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test. « less
- Open Access
- 18 July 2019
- Published by Office of Scientific and Technical Information (OSTI)
Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media
The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar mediamore » under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): • CST in water at 25°C tested to 300 Mrad total dose • wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose • dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose • CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose • CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values[1] for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test. « less
- 18 July 2019
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessGas Generation Testing of Crystalline Silicotitanate Ion Exchange Media
The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar mediamore » under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): • CST in water at 25°C tested to 300 Mrad total dose • wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose • dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose • CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose • CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values[1] for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test. « less
- 26 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1932-1941
Cesium removal from AP-105 Hanford tank waste using spherical resorcinol formaldehyde resin
Spherical resorcinol formaldehyde (SRF) resin is planned for use in removing cesium (137Cs) from Hanford tank waste supernates in preparation for waste vitrification at the Waste Treatment and Immobilization Plant. The results of six complete load/elute cycles using 12 L of Hanford tank waste supernatant collected from Tank AP-105 are provided. Testing exposed SRF to the combined sources of chemical degradation, physical stresses, and radiolytic exposure. Decreased flowrates and increased elution volumes improved performance. Increased cycling decreased performance; increased flowrate increased mass transfer zones; Cs leakage into ensuing cycle increased with decreased eluate volume, and analyte mass fractionation were examined.
- 26 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1932-1941
Cesium removal from AP-105 Hanford tank waste using spherical resorcinol formaldehyde resin
Spherical resorcinol formaldehyde (SRF) resin is planned for use in removing cesium (137Cs) from Hanford tank waste supernates in preparation for waste vitrification at the Waste Treatment and Immobilization Plant. The results of six complete load/elute cycles using 12 L of Hanford tank waste supernatant collected from Tank AP-105 are provided. Testing exposed SRF to the combined sources of chemical degradation, physical stresses, and radiolytic exposure. Decreased flowrates and increased elution volumes improved performance. Increased cycling decreased performance; increased flowrate increased mass transfer zones; Cs leakage into ensuing cycle increased with decreased eluate volume, and analyte mass fractionation were examined.
- 22 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1942-1951
Cesium ion exchange testing using crystalline silicotitanate with Hanford tank waste 241-AP-107
Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low Activity Waste Pretreatment System with actual Hanford tank waste. Crystalline silicotitanate (CST) ion exchange media is planned to be used to remove cesium (137Cs) from the aqueous phases of the tank wastes. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Removal of Cs from these wastes is an important processing step in preparing the waste for long-term safe storage. Batch contact testing was performed to find the Cs load capacity at the equilibrium feed condition. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using CST. Column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Feed was processed until the lag column effluent reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations), at which point, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected batch contact and lead column samples were analyzed to assess particular metal analyte load characteristics. Results of these analyses will be discussed.
- 22 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1942-1951
Cesium ion exchange testing using crystalline silicotitanate with Hanford tank waste 241-AP-107
Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low Activity Waste Pretreatment System with actual Hanford tank waste. Crystalline silicotitanate (CST) ion exchange media is planned to be used to remove cesium (137Cs) from the aqueous phases of the tank wastes. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Removal of Cs from these wastes is an important processing step in preparing the waste for long-term safe storage. Batch contact testing was performed to find the Cs load capacity at the equilibrium feed condition. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using CST. Column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Feed was processed until the lag column effluent reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations), at which point, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected batch contact and lead column samples were analyzed to assess particular metal analyte load characteristics. Results of these analyses will be discussed.
- 7 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1922-1931
Small- to large-scale comparisons of cesium ion exchange performance with spherical resorcinol formaldehyde resin
Ion exchange performance using spherical resorcinol formaldehyde resin was compared at three process scales (10 mL, 34 gal, and 297 gal). The small-scale test demonstrated earlier cesium breakthrough, but higher cesium capacity, relative to the large-scale tests. The low superficial flow velocity at the small scale impacted the cesium load profile resulting in a longer transition zone. Based on these results, small-scale column test results with actual tank waste will likely be worst case bounding with respect to initial cesium breakthrough and transition zone length, but could overpredict cesium capacity when extrapolated to large-scale column operations.
- 7 February 2019
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 54  (12) , 1922-1931
Small- to large-scale comparisons of cesium ion exchange performance with spherical resorcinol formaldehyde resin
Ion exchange performance using spherical resorcinol formaldehyde resin was compared at three process scales (10 mL, 34 gal, and 297 gal). The small-scale test demonstrated earlier cesium breakthrough, but higher cesium capacity, relative to the large-scale tests. The low superficial flow velocity at the small scale impacted the cesium load profile resulting in a longer transition zone. Based on these results, small-scale column test results with actual tank waste will likely be worst case bounding with respect to initial cesium breakthrough and transition zone length, but could overpredict cesium capacity when extrapolated to large-scale column operations.
- Open Access
- 1 February 2017
- Published by SAGE Publications in Health Security
- Vol. 15  (1) , 70-80
Evaluation of PCR Systems for Field Screening of Bacillus anthracis
There is little published data on the performance of hand-portable polymerase chain reaction (PCR) systems that can be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated 5 commercially available hand-portable PCR instruments for detection of Bacillus anthracis . We used a cost-effective, statistically based test plan to evaluate systems at performance levels ranging from 0.85-0.95 lower confidence bound (LCB) of the probability of detection (POD) at confidence levels of 80% to 95%. We assessed specificity using purified genomic DNA from 13 B. anthracis strains and 18 Bacillus near neighbors, potential interference with 22 suspicious powders that are commonly encountered in the field by first responders during suspected biothreat incidents, and the potential for PCR inhibition when B. anthracis spores were spiked into these powders. Our results indicate that 3 of the 5 systems achieved 0.95 LCB of the probability of detection with 95% confidence levels at test concentrations of 2,000 genome equivalents/mL (GE/mL), which is comparable to 2,000 spores/mL. This is more than sufficient sensitivity for screening visible suspicious powders. These systems exhibited no false-positive results or PCR inhibition with common suspicious powders and reliably detected B. anthracis spores spiked into these powders, though some issues with assay controls were observed. Our testing approach enables efficient performance testing using a statistically rigorous and cost-effective test plan to generate performance data that allow users to make informed decisions regarding the purchase and use of field biodetection equipment.
- 1 February 2017
- Published by SAGE Publications in Health Security
- Vol. 15  (1) , 70-80
Open AccessEvaluation of PCR Systems for Field Screening of Bacillus anthracis
There is little published data on the performance of hand-portable polymerase chain reaction (PCR) systems that can be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated 5 commercially available hand-portable PCR instruments for detection of Bacillus anthracis . We used a cost-effective, statistically based test plan to evaluate systems at performance levels ranging from 0.85-0.95 lower confidence bound (LCB) of the probability of detection (POD) at confidence levels of 80% to 95%. We assessed specificity using purified genomic DNA from 13 B. anthracis strains and 18 Bacillus near neighbors, potential interference with 22 suspicious powders that are commonly encountered in the field by first responders during suspected biothreat incidents, and the potential for PCR inhibition when B. anthracis spores were spiked into these powders. Our results indicate that 3 of the 5 systems achieved 0.95 LCB of the probability of detection with 95% confidence levels at test concentrations of 2,000 genome equivalents/mL (GE/mL), which is comparable to 2,000 spores/mL. This is more than sufficient sensitivity for screening visible suspicious powders. These systems exhibited no false-positive results or PCR inhibition with common suspicious powders and reliably detected B. anthracis spores spiked into these powders, though some issues with assay controls were observed. Our testing approach enables efficient performance testing using a statistically rigorous and cost-effective test plan to generate performance data that allow users to make informed decisions regarding the purchase and use of field biodetection equipment.